37112-1-1019Page 2 Empire Comfort Systems Inc. • Belleville, IL
PARTS LIST
PART DESCRIPTION CONVERSION KIT - 35396 CONVERSION KIT - 35398 QUANTITY SUPPLIED
PilotOrice R7658 R10426 1
MainBurnerOrice P210 P210 1
LP Flue Restrictor
36008 36008 1
SITGasValveConversionKit
R7657 R11169 1
GasConversionLabel 2139 2139 1
Tools Needed:StandardScrewdriver,1/4"HexDriver,5/16"HexDriver,3/8"and1/2"Wrenches
Gas input for direct vent replace insert converted to Propane Gas:
• DVCP36(PP,SP)3032,000Btuperhour
• DVCP36(PP,SP)7032,000Btuperhour
ThedirectventgasreplacewhenconvertedtoPropaneGaswillhaveamanifoldpressureapproximately10.0"w.c.
(2.49kPa)foramaximuminputor4.9"w.c.(1.220kPa)foraminimuminputatthevalveoutletwiththeinletpressuretothe
valvefromaminimumof11.0"w.c.(2.739kPa)forthepurposeofinputadjustmenttoamaximumof13.0"w.c.(3.235kPa).
INSTRUCTIONS FOR CONVERSION
1. Ifthereplaceinsertisinstalled,turnOFFgasandelectricsupplytoreplacebeforemakinggasconversion.
2. Removeaccesspanelbelowglass;liftandpullawayfromreplace.
3. Releasethetwoglassframespringclampsbeneathoneofthetwoglassframes.
4. Removetheglassframeandscreenframeasanassembly.
5. Removelogsfromburnerassembly.
6. Removethetenscrewsaroundtheburnerperimeter,andremovethefalseoorfromtheburnerassembly.
7. Removethefourscrewsretainingtheburnertotheburnerbase,andremoveburner.
8. RemoveNaturalGasmainburneroricefromoricetting.
9. InstallPropaneGasmainburneroriceintooricetting:
• forDVCP36(PP,SP)30,OriceisMARKED #51
• forDVCP36(PP,SP)70,OriceisMARKED #51
10. Pullupwardonpilothoodtoremoveandgainaccesstopilotinjectororice.
11. RemoveNaturalGaspilotinjectororicefrompilotburnerwith5/32"hex(Allen)wrench.
12. InsertIncludedPropaneGaspilotinjectororiceintopilotburnerusinga5/32"hexwrench.
13. Re-installpilothoodtopilotassembly.Pushdownwardtosnapinplace.
14. ForDVCP36(PP,SP)30only,convertgasvalveasinstructedinS.I.T.PropaneGasValveConversionKit.
15.
ForDVCP36(PP,SP)70only,removeNaturalGasvalvefrommanifoldpipeandreplacewithincludedPropaneGasvalve.
16. Adjustairshuttersettingto3/16”open(1/8”with40ft.verticalvent).
17. Replacetheburnerassemblyontotheburnerbase.
18. Replacethefalseoortotheburner.
19. Forverticallyventedinstallationsonly,replacetheuerestrictorwithincludedPropaneGasuerestrictor.
20. Replacelogset.
21. Replaceglassandscreenframes,andloweraccesspanel.
22.
Theconvertedreplacemustbeconnectedtoasupplyoftheconversiongasandcheckedforleaksatallconnections.