Pentair DP233110V User manual

Category
Water pumps
Type
User manual

This manual is also suitable for

OWNER’S MANUAL
Sink Pump System
© 2006 S483 (Rev. 9/26/06)
4943 0405
DP233110V-01
Installation/Operation/Parts
293 Wright Street • Delavan, WI 53115
General Safety Information 2
DESCRIPTION
The Sta-Rite Sink Pump System, Model Number
DP233110V-01, is ideal for home wastewater removal
from beautician or utility sinks and wet bars, and for drain
water transfer from air conditioners or dehumidifiers.
1/3 HP submersible pump unit is equipped with a 3-prong
grounding-type power cord. Motor is oil-filled (dielectric
oil) and sealed for cooler running. Upper sleeve/lower
ballbearing on motor shaft never need lubrication.
Automatic reset thermal protection.
SPECIFICATIONS
Power supply required...................................115V, 60 Hz.
Liquid temp. range..........................................32° to 130°F
Individual branch circuit required (minimum)......15 Amps
Discharge...........................................................1-1⁄2" NPT
UNPACKING AND INSPECTION
Handle with care. Check items received against packing
list to be sure that all equipment has been received.
Inspect for shipping damage. If found, file claim with carri-
er immediately.
GENERAL SAFETY INFORMATION
Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris in the
sump, flooding that exceeds the pump’s capacity, electri-
cal or mechanical failure in the pump, etc.) may prevent
the pump from functioning normally. To prevent possible
water damage due to flooding, consult your dealer about
installing a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common
sump pump problems and remedies. For more informa-
tion, see your dealer or call customer service.
1. Know the pump application, limitations, and potential
hazards.
2. Disconnect power before servicing.
3. Release all pressure within system before servicing any
component.
4. Drain all water from system before servicing.
5. Secure discharge line before starting pump. An unse-
cured discharge line will whip, possibly causing per-
sonal injury and/or property damage.
6. Check hoses for weak or worn condition before each
use, making certain that all connections are secure.
7. Periodically inspect system components. Keep free of
debris and foreign objects. Perform routine mainte-
nance as required.
8. Provide means of pressure relief for pumps whose dis-
charge line can be shut-off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times when working with
pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment.
c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, mas-
ter switches, and by removing starter keys.
10. When wiring an electrically driven pump, follow all
electrical and safety codes that apply.
11. This equipment is only for use on 115 volt (single
phase) and is equipped with an approved
3-conductor cord and 3-prong, grounding-type plug.
To reduce risk of electric shock, pull plug
before servicing. This pump has not been investigated for
use in swimming pool areas. Pump is supplied with a
grounding conductor and grounding-type attachment plug.
Be sure it is connected only to a properly grounded
grounding-type receptacle. Where a 2-prong wall recepta-
cle is encountered, it must be replaced with a properly
grounded 3-prong receptacle installed in accordance with
codes and ordinances that apply.
12. All wiring should be performed by a qualified
electrician.
13. Make certain power source conforms to requirements
of your equipment.
PERFORMANCE
SPECIFICATIONS
Motor
Full Load Switch Setting Top Bottom
HP Amps On Off Height Width Width Weight
1/3 9.8 7" 2" 13-3/4" 15-1/8" 12" 32 lbs.
GPM of Water @ Total Feet of Head
Model HP 5’ 10’ 15’ 20’ Shutoff
DP233110V-01 1/3 48.0 40.0 29.0 15.0 24’
General Safety / Assembly 3
14. Protect electrical cord from sharp objects, hot surfaces,
oil, and chemicals. Avoid kinking cord. Replace or
repair damaged or worn cords immediately.
15. Do not touch an operating motor. Modern motors are
designed to operate at high temperatures.
Risk of electric shock. If your basement has
water or moisture on the floor, do not walk on wet area
until all power has been turned off. If shut-off box is in
basement, call electric company or hydro authority to
shut-off service to house, or call your local fire department
for instructions. Remove and replace system. Failure to fol-
low this warning can result in fatal electrical shock.
Risk of electric shock. Do not handle pump
or pump motor with wet hands or when standing on wet
or damp surface, or in water. Always disconnect the pump
and switch from the electrical power source before doing
any maintenance.
16. Pump water only with this pump.
ASSEMBLY
Steps 1 and 2 (See Figure 1)
Step 3 (See Figure 2)
Step 4 (See Figure 3)
Install the discharge pipe hand-tight plus one-half turn.
Step 5 (See Figure 4)
Place the pump in the basin as shown. Align the discharge
with one of the threaded ports in the cover.
Step 6 (See Figure 5)
Turn the cover upside down and ‘lay in’ the basin gasket
as shown.
1
2
Figure 1
3
Figure 2
4
Figure 3
Inlet
Pump
Basin
1 " NPT
Discharge
1 " NPT
Vent
1
2
1
2
Figure 4
Locating
Cleats
Figure 5
Assembly / Installation 4
IMPORTANT: To prevent leaks, be sure that the cleats on
the corners of the basin gasket are up with the cover
upside down (that is, not pressed into the sealing face of
the cover).
Step 7 (See Figure 5)
Push the screws with their washers installed up through
the holes in the rim of the cover and in the basin gasket
(the cover will retain the screws).
Step 8 (See Figure 6)
Align the cover with the discharge pipe and cords.
Pull the cords through the non-threaded hole in the
basin cover.
Place the cover over the discharge pipe.
Install the cords in the cord grommet
Install the cord/grommet assembly in the non-threaded
hole in the basin cover; don’t pull the cords tight.
Step 9 (See Figure 6)
Fasten the basin cover to the basin with the capscrews
previously inserted in the cover (Step 7).
IMPORTANT: To prevent leaks, be sure the locating cleats
on the corners of the basin gasket are outside the edges of
the basin rim, not pressing against the rim.
INSTALLATION (See Figure 7)
The basin (system) should be located at the lowest place
possible relative to the area to be drained.
NOTE: Make sure that the inlet of the pre-plumbed system
is lower than the water to be pumped.
1. Install inlet pipe in opening as shown. Use RTV sealants
or Plasto-Joint Stik* to seal threads. See Figures 8, 9, and
10, page 4 and 5, for typical installation arrangements.
*Lake Chemical Co., Chicago, Illinois
1 " NPT
Discharge
Thread pipes into fittings;
don't go past end of threads.
1 " NPT
Inlet
15
1
/
8"
13
3
/
4"
12"
12"
Vertical Float Switch
1/3 HP
Pump
1 " NPT
Vent
1
2
1
2
1
2
Figure 7 – Sink Pump System Dimensions
4720 1004
Pump
Inlet
1 " NPT
Vent
Cord Grommet
1 " NPT
Discharge
Discharge
1
2
1
2
Figure 6
Discharge
Vent
Pump
Figure 8 – Typical installation to remove air conditioner
condensate or dehumidifier water
Installation / Maintenance 5
2. Install discharge plumbing. When using rigid pipe, use
plastic pipe. Wrap thread with Teflon tape or use
Plasto-Joint Stik*. Screw pipe into discharge fitting
hand tight +1 – 1-1⁄2 turns.
NOTE: Do not use ordinary pipe joint compound on plas-
tic pipe. Pipe joint compound can attack plastics.
3. To reduce motor noise and vibrations, a short length of
rubber hose (1-7⁄8" I.D., e.g. radiator hose) can be con-
nected into discharge line near pump using suitable
clamps.
4. Install an in-line check valve to prevent flow back-
wards through pump when pump shuts off.
5. Thread vent pipe into 1-1⁄2" NPT black vent fitting in
basin cover. Pipe should not extend into basin.
Connect vent pipe to sewer vent system.
6. Power Supply: Pump is designed for 115 V., 60 Hz.,
operation and requires a minimum 15 amp individual
branch circuit. Both pump and switch are supplied
with 3-wire cord sets with grounding-type plugs.
Switch plug is inserted directly into outlet and pump
plug inserts into opposite end of switch plug.
Hazardous Voltage. Pump should always be
electrically grounded to a suitable electrical ground such
as a grounded water pipe or a properly grounded metallic
raceway or ground wire system. Do not cut off round
ground pin.
7. If pump discharge line is exposed to outside sub-freez-
ing atmosphere, portions of line exposed must be
installed so any water remaining in pipe will drain to
the outfall by gravity. Failure to do this can cause
water trapped in discharge to freeze which could result
in damage to pump.
8. After piping and check valve have been installed, unit
is ready for operation.
9. Check operation by filling sump with water and
observing pump operation through one complete
cycle.
Risk of flooding. Failure to make this opera-
tional check may lead to improper operation, premature
failure, and flooding.
MAINTENANCE
Risk of electric shock. Make certain that the
pump is unplugged before attempting to service or remove
any component.
Risk of electric shock. Do not handle a
pump or pump motor with wet hands or when standing
on wet or damp surface, or in water.
1. Keep pump inlet screen clear.
2. Shaft seal depends on water for lubrication. Do not
operate pump unless it is submerged in water as seal
may be damaged if allowed to run dry.
3. Motor is equipped with automatic reset thermal protec-
tor. If temperature in motor should rise unduly, switch
will cut off all power before damage can be done to
motor. When motor has cooled sufficiently, switch will
reset automatically and restart motor. If protector trips
repeatedly, pump should be removed and checked for
cause of difficulty. Low voltage, long extension cords,
clogged impeller, very low head or lift, etc., could
cause cycling. Refer to Trouble shooting Guide on
Page 6 for additional information.
4. Periodically inspect pump, system components, and
sump for debris and foreign objects. Keep sump free of
all refuse. Perform routine maintenance as required.
Pump Cleaning
NOTE: Attempting to disassemble motor will void warranty.
1. Use the pump ring to lift pump out of basin and place
pump on a clean level surface.
Risk of electrical shock. Shock can burn or
kill. Do not lift pump by power cord.
2. To clean impeller, remove eight screws holding base-
plate to motor assembly. Clean impeller as necessary.
3. Re-install baseplate and screws.
4. Use pump ring to replace pump in basin.
Discharge
Vent
Pump
Figure 9 – Typical wet bar installation
Discharge
Vent
Pump
Figure 10 – Typical installation for laundry sinks and
washing machines
Maintenance 6
SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Pump won’t 1. Blown fuse. 1. If blown, replace with fuse of proper size.
start or run.
2. Low line voltage. 2. If voltage under recommended minimum,
check size of wiring from main switch on
property. If OK, contact power company or
hydro authority.
Pump won’t 1. Restricted discharge 1. Remove obstacle in piping.
shut off. (obstacle in piping).
Pump operates 1. Restricted discharge 1. Remove obstacle in piping.
but delivers (obstacle in piping).
little or no water.
Switch Replacement
Risk of electric shock. When servicing
pump, always disconnect power to electrical outlet and
remove pump electric cord from outlet.
Float must be able to complete its entire
cycle without interference from sidewall of basin, plumb-
ing, or any other object.
1. Mount bracket on switch housing using existing screws.
2. Slide rod into slot in bottom of switch housing. Fasten
rod into switch housing with pin.
Make sure pin holds float rod in switch
housing; otherwise pump will not shut off.
NOTE: Pull gently on rod to make sure that it cannot
come out of switch housing.
3. Mount switch assembly on pump using existing
screws. Make sure that nothing interferes with switch
operation.
4. Mount float on rod.
5. Install rod stop on bottom of rod.
6. Run pump through one complete cycle to verify cor-
rect switch operation.
Risk of flooding. Drainer Pre-Plumbed
System comes with the automatic float switch mounted on
the motor housing ready for operation. Do not change
switch settings. Switch is set to start at approximately 6.5"
and to stop at approximately 2".
TROUBLESHOOTING
Repair Parts 7
3
2
1
5
4
Key Part
No. Description Qty. DP233110V-01
1 5 gallon Poly basin assembly (includes Key No. 2 and hardware kit) 1 PW73-64
2 Basin Gasket 1 U20-23
3 Automatic Vertical Float Switch 1 PKG 208
4 1-1/2" Discharge Pipe 1 U37-688P
5 1/3 HP Submersible sump pump 1 D33110V
Hardware kit (includes bolts, washers, and cord grommet) 1 PW198-6
Repair Parts List
• Not illustrated.
Warranty 8
LIMITED WARRANTY
Pentair Water (“Pentair”) warrants to the original consumer of the products listed below, that they will be free from defects in material
and workmanship for the Warranty Period from the date of original installation or manufacture as noted.
Product Warranty Period
Jet pumps, small centrifugal pumps,
whichever occurs first:
submersible pumps and related accessories 1 year from date of original installation, or
2 years from date of manufacture
Hydro-Flow Filters 1 year from date of purchase
Fibrewound Tanks 5 years from date of original installation
Steel Pressure Tanks 5 years from date of original installation
Epoxy-Lined Tanks 3 years from date of original installation
Sump/Sewage/Effluent Products 1 year from date of original installation, or
2 years from date of manufacture
Our warranty will not apply to any product that has been subject to negligence, misapplication, improper installation or maintenance. In the
event a three phase submersible motor is operated with single phase power through a phase converter, or if three-leg ambient compensat-
ed, extra-quick trip overload relays of recommended size are not used, our warranty is void.
Buyer’s only remedy and Pentair’s only duty is to repair or replace defective products (at Pentair’s choice). Buyer agrees to pay all labor and
shipping charges associated with this warranty and to request warranty service through the installing dealer as soon as a problem is discov-
ered. If warranty service is requested more than 30 days after the Warranty Period has ended, it will not be honored.
PENTAIR SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE, SHALL NOT EXTEND BEYOND THE WARRANTY PERIOD PROVIDED HEREIN.
Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the duration of
an implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth specific legal rights and obligations,
however, additional rights may exist, which may vary from state to state.
Supersedes all previous publications.
Pentair Water, 293 Wright St., Delavan, WI 53115
MANUAL DE INSTRUCCIONES
Sistema de bomba
para sumidero
© 2006 S483 (Rev. 9/26/06)
4943 0405
DP233110V-01
Instalación/Operación/Piezas
293 Wright Street • Delavan, WI 53115
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Pentair DP233110V User manual

Category
Water pumps
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI