OWON HDS1022M-N User manual

Category
Measuring, testing & control
Type
User manual

This manual is also suitable for

HDS Series Handheld Digital Storage
Oscilloscope & Multimeter
User Manual
HDS1022M HDS2062M
WWW.OWON.COM.CN
Dec. 2009 edition
Copy Right in this Manual © Lilliput Company. All rights have been reserved.
The Lilliput’s products are under the protection of the patent rights in America and other countries,
including ones which have already obtained the patent rights and those which are applying for.
The information in this manual will replace all that in the materials published originally.
The information in this manual was correct at the time of printing. However, OWON will continue
to improve products and reserves the rights to changes specification at any time without notice.
OWON is the registered trademark of the Lilliput Company.
Xiamen Lilliput Technology Co.,Ltd.: the 5th floor, B Area, Chuangxin Mansion, Software
Park,ZhenZhuWan, Huandao RD, Xiamen,Fujian,China
Fujian Lilliput Optoelectronics Technology Co.,Ltd.:The mansion of optoelectronics hengsan
road, Lantian industrial zone ,Zhangzhou,Fujian,China
Tel:+86-592-2575666
Fax:+86-592-2575669
General Warranty
The Lilliput warrants that the product will be free from defects in materials and
workmanship for a period of three years from the date of purchase of the product by
the original purchaser from the Lilliput company. And the warranty period of
accessories such as probe, battery, adapter is one year. This warranty only applies to
the original purchaser and is not transferable to the third party. If the product proves
defective during the warranty period, Lilliput either will repair the defective product
without charge for parts and labor, or will provide a replacement in exchange for the
defective product. Parts, modules and replacement products used by Lilliput for
warranty work may be new or reconditioned to like new performance.All replaced
parts, modules and products become the property of Lilliput.
In order to obtain service under this warranty, Customer must notify Lilliput of the
defect before the expiration of the warranty period. Customer shall be responsible for
packaging and shipping the defective product to the service center designated by
Lilliput, and with a copy of customer proof of purchase.
This warranty shall not apply to any defect, failure or damage caused by improper use
or improper or inadequate maintenance and care. Lilliput shall not be obligated to
furnish service under this warranty a) to repair damage resulting from attempts by
personnel other than Lilliput representatives to install, repair or service the product; b)
to repair damage resulting from improper use or connection to incompatible
equipment; c) to repair any damage or malfunction caused by the use of non-Lilliput
supplies; or d) to service a product that has been modified or integrated with other
products when the effect of such modification or integration increases the time or
difficulty of servicing the product.
Please contact the nearest Lilliput’s Sales and Service Offices for services or a
complete copy of the warranty statement.
Excepting the after-sales services provided in this summary or the applicable warranty
statements, Lilliput will not offer any guarantee for maintenance definitely declared or
hinted, including but not limited to the implied guarantee for marketability and
special-purpose acceptability. Lilliput should not take any responsibilities for any indirect,
special or consequent damages.
OWON HDS Series Handheld DSO & DMM Contents
1
Table of Contents
Chapter Page
1.DECLARATION OF CONFORMITY·················································· 1
1.1 Declaration of Conformity ·······································································································1
1.2 Open the Oscilloscope Parts Box,You Can See the Parts Below (see the picture below) ····1
2.SAFETY INFORMATION····································································· 2
2.1 Safety Terms and Symbols·······································································································2
2.1.1 Specific Warning and Caution Terms that Appear throughout the Manual··············2
2.1.2 Terms Used on the Product···························································································2
2.1.3 Symbols Used on the Product.·····················································································2
2.2 General Safety Information ·····································································································3
3. GENERAL CHARACTERISTICS OF THE HDS SERIES
OSCILLOSCOPE ······················································································ 5
4.PERFORMING THE GENERAL INSPECTION ······························ 6
4.1 Performing the General Inspection ·························································································6
4.1.1 Check whether there is any Damage on it Due to Transportation····························6
4.1.2 Make a Check on Accessories ·····················································································6
4.1.3 Make a Check on the Complete Instrument································································6
5.INPUT CONNECTIONS······································································· 7
5.1 Input Connections ·····················································································································7
5.2 Description for Front Panel and Keys·····················································································8
6.USING THE SCOPE··········································································· 10
OWON HDS Series Handheld DSO & DMM Contents
2
6.1 About this Chapter··················································································································10
6.2 Power-Up the Oscilloscope·····································································································10
6.3 Oscilloscope Operation Window····························································································10
6.4 Navigating a Menu ··················································································································12
6.5 Manually Setting the Vertical System, Horizontal System and Trigger Position ·············13
6.6 Resetting the Oscilloscope ······································································································16
6.7 Input Connections ···················································································································17
6.8 Displaying an Unknown Signal with Auto Set······································································17
6.9 Automatic Zero-returning of Trigger Horizontal Position and Trigger Level Position ···18
6.10 Automatic Measurements·····································································································18
6.11 Freezing the Screen···············································································································19
6.12 Using Average for Smoothing Waveforms··········································································19
6.13 Using Persistence to Display Waveforms ············································································20
6.14 Using Peak Detection to Display Glitches ···········································································21
6.15 Selecting AC-coupling···········································································································23
6.16 Reversing the Polarity of the Displayed Waveform ···························································23
6.17 Using Waveform Mathematics Functions···········································································24
7.USING THE MULTIMETER······························································· 26
7.1 About this Chapter··················································································································26
7.2 Making Meter Connections····································································································26
7.3 Multimeter Operation Window ·····························································································26
7.4 Making Multimeter Measurements·······················································································27
7.4.1 Measuring Resistance Values ····················································································28
7.4.2 Making a Diode Measurement····················································································28
7.4.3 On-off Test·····················································································································29
7.4.4 Making a Capacitance Measurement········································································30
7.4.5 Making a DC Voltage Measurement··········································································30
OWON HDS Series Handheld DSO & DMM Contents
3
7.4.6 Making a AC Voltage Measurement···········································································31
7.4.7 Making a DC Current Measurement··········································································32
7.4.8 Making an AC Current Measurement ········································································33
7.5 Freezing the Readings·············································································································34
7.6 Taking a Relative Measurement·····························································································35
7.7 Selecting Automatic/ManualRange Adjustment ··································································36
8.ADVANCED FUNCTION OF OSCILLOSCOPE·······················37
8.1 About this Chapter··············································································································37
8.2 Setting the Vertical CH1 and CH2·····················································································37
8.2.1 Setting the Channel Coupling·················································································38
8.2.2 Make Open and Close Settings on Channel·························································39
8.2.3 Adjusting the Probe Scale·······················································································39
8.2.4 Setting of Inverted Waveform ·················································································40
8.3 Make the Math Function Menu Setting ············································································40
8.4 Setting the Trigger System ·································································································41
8.5 Triggering Control ··············································································································42
8.5.1 Edge Triggering········································································································42
8.5.2 Video Triggering·······································································································43
8.6 Acquiring Mode Setting······································································································46
8.7 Display Setting·····················································································································46
8.7.1 Display Style·············································································································46
8.7.2 Persistence···············································································································47
8.7.3 XY Mode····················································································································48
8.8 Waveform Saving Setups····································································································48
8.9 Function Setting Menu ·······································································································49
8.10 Making Automatic Measurements···················································································50
8.11 Setting the Cursor Measurements····················································································52
8.12 Autoscale····························································································································54
8.13 System State Menu ············································································································57
OWON HDS Series Handheld DSO & DMM Contents
4
8.14 Setting of Time Base Mode·······························································································58
8.15 Data Transmission·············································································································59
9.TROUBLE SHOOTING······································································ 60
10.APPENDIX·························································································· 61
10.1 Appendix a Specifications·····································································································61
10.1.1 Oscilloscope ···············································································································61
10.1.2 Meter ···························································································································63
10.1.3 General Specifications·······························································································64
10.2 Appendix B: Maintenance and Cleaning ············································································65
10.2.1 Common Maintenance······························································································65
10.2.2 Storage of Oscilloscope·····························································································66
10.2.3 Replacing the Lithium Battery Unit···········································································66
OWON HDS Series Handheld DSO & DMM 1-Declaration of Conformity
1
1.Declaration of Conformity
1.1 Declaration of Conformity
HDS Series Handheld Digital Storage Oscilloscope & Multimeter
Manufacturer: Fujian Lilliput Optoelectronic Technology Co., Ltd.
Statement of Conformity
Base on the result using appropriate standards,the product is in conformity with
Electromagnetic Compatibility Directive 89/336/EEC
Low Voltage Directive 73/23/EEC
Sample tests
Standards used:
EN61010.120012nd edition
Safety Requirements for Electrical Equipment for Measurement, Control, and
Laboratory use-part 1:General Requirements
EN613261997+A11998+A22001+A32003
Electrical Equipment for Measurement, Control and Laboratory use-EMC
Requirements-part 1. General Requirements
EN61000-3-22000+A22005
Electromagnetic Compatibility(EMC)-part 3:Limits-Section 2:Limits for Harmonic
Current Emissions (Equipment Input Current less than/equal to 16A per phase)
EN61000-3-31995+A12001
Electromagnetic Compatibility (EMC)-part 3:Limits-Section 3 Limitation of Voltage
Fluctuations and Flicker in Low-Voltage Supply systems for Equipment with Rated
Current less than or equal to 16A
The tests have been performed in typical configuration.
This conformity is indicated by the symbol CE, i.e."Conformite Europeenne".
OWON HDS Series Handheld DSO & DMM 1-Declaration of Conformity
1
1.2 Open the Oscilloscope Parts Box,You Can See the Parts
Below (see the picture below)
# Description Standard Optional
1 Oscilloscope and Battery
2 Battery Charger
3 Oscilloscope Probe x 2 (grey)
4 Multimeter test lead x 2 (black and red)
5 Extension module for big current measurement
6 Module for small capacitance measurement
7 Probe adjustment tools
8
USB communication cable or RS-232C
communication cable
9 User Manual
10 CD-ROM (software)
11 Hard carrying case
12 Soft carrying case
13
5v output cable with a frequency of 1 kHz as the
test-signal(Only for the HDS1022M .)
figure 1: Digital Oscilloscope Parts
OWON HDS Series Handheld DSO & DMM 2-Safety Information
2
2.Safety Information
In order to ensure the correct using and the best efficient service, please carefully read this user’s
manual.
2.1 Safety Terms and Symbols
2.1.1 Specific Warning and Caution Terms that Appear throughout the
Manual
Warning: “Warning” identifies conditions and actions that pose hazards to the users.
Caution: “Caution” identifies conditions and actions that may damage the product or
other properties.
2.1.2 Terms Used on the Product
The following terms appears possibly on the product:
Danger: The term “Danger” is used in this manual to indicate that when you read this
mark, personal injury may be caused to you immediately.
Warning: The term “Warning” is used in this manual to indicate that when you read this
mark, personal injury may not be caused to you immediately, but you need to
be cautionary.
Notice: The term “Notice” is used in this manual to indicate that damages may be
caused on this product or other properties.
2.1.3 Symbols Used on the Product.
The following symbols appear possibly on the product.
High Voltage Please Consult the Manual. Protective Ground End Earth End on the Shell Grounding End for Measurement
OWON HDS Series Handheld DSO & DMM 2-Safety Information
3
2.2 General Safety Information
Carefully read the following safety information in order to avoid any personal injury and damage
on this product or any products connected with it. This product can only be used in the specified
applications to prevent any possible dangers.
Warning:
To avoid fire or electrical shock. Please use proper power adapter. Use only the power
adapter appointed by the manufacturer and subject to approval of being used in the users
country.
Warning:
To avoid fire or electrical shock if a test tool input is connected to more 42V peak (30Vrms)
or on circuits of more than 4800VA:
Use only insulated voltage probes, test leads and adapter supplied with the test tool, or
indicated by OWON as suitable for the Oscilloscope & Multimeter.
Before use, inspect voltage probes, test leads and accessories for mechanical damage and
replace when damaged.
Remove all probes, test leads and accessories that are not in use.
Always connect the power adapter first to the AC outlet before connecting it to the
Oscilloscope & Multimeter.
Do not apply voltages that differ more than 400 V from earth ground to any input when
measuring in a CAT environment.
Do not apply voltages that differ more than 400 V from each other to the isolated inputs
when measuring in a CAT environment.
Do not apply input voltages above the rating of the instrument Use caution when using
1:1 test leads because the probe tip voltage will be directly transmitted to the
Oscilloscope & Multimeter.
Do not use exposed metal BNC or banana plug connectors.
Do not insert metal objects into connectors.
Always use the Oscilloscope & Multimeter only in the manner specified.
Voltage ratings that are mentioned in the warning, are giver as limits for “working
voltage”. The represent V ac rms (50-60Hz) for AC sine wave applications and as V dc
for DC applications. Overvoltage Category refers to local level , CAT is the prefix
refers to level II, Class II is a low-voltage high-energy level, which is applicable for
appliances and portable equipment .
OWON HDS Series Handheld DSO & DMM 2-Safety Information
4
Only qualified technical personnel are permitted to perform maintenance.
Pay attention to the nominal values of all terminals:To avoid fire or electric shock, please keep
a watchful eye on all nominal values and marks specified for this product. Before any connection
performed on this product, carefully read the user’s manual of the product for further information
of nominal values.
No operation is allowed without the instrument cover plate: If the cover plate or panel has
been removed, do not perform any operation on this product.
No touch is allowed on bare conductors:When the product is powered on, do not touch any bare
joints or parts of the scope meter.
Operation is prohibited in case of any undetermined failure:When in doubt any damage on
this product, consult the qualified personnel for checking on it.
Keep ventilation in good condition:Refer to the user manual for detail installation instructions in
order to fix this product correctly and provide it with good ventilation conditions.
No operation is allowed under a humid environment.
No operation is allowed under an explosive environment.
Keep clean and dry on the product surface.
The method which stipulated according to the factory does not use the equipment, possibly can
damage the protection which the equipment provides.
OWON HDS Series Handheld DSO & DMM 3-General Characteristics
5
3. General Characteristics of the HDS
Series Oscilloscope
Record length of 6,000 points for each channel;
Reading-out with the cursor;
Twenty automatic measurement functions;
Autoscale function;
Color liquid crystal display of high resolution and high contrast with
adjustable back light;
Storage and call-out of waveforms;
Automatic setting function provided capable of fast setting;
Multiple-waveform calculation function;
Implementation of detecting the average and peak values of the waveform;
Edge and video triggering function;
RS232 or USB communication ports;
Multiple Language User Interface
OWON HDS Series Handheld DSO & DMM 4-Performing the General Inspection
6
4.Performing the General Inspection
4.1 Performing the General Inspection
When you have got a new HDS series oscilloscope, it is suggested that you should perform a
general inspection on the instrument according to the following steps.
4.1.1 Check whether there is any Damage on it Due to Transportation
If the packing boxes or foam cushions are found in serous damage, keep them in a proper place till
the complete instrument and accessories have passed the electrical and mechanical tests.
4.1.2 Make a Check on Accessories
The accessory list has been described in the picture of Digital Oscilloscope Parts of this manual.
You can make a check and find whether there is any accessory loss with reference to the
Appendix. In case of any accessory loss or damage, consult the OWON dealer responsible for
such a business or the local office of OWON.
4.1.3 Make a Check on the Complete Instrument
If the instrument is damaged in its appearance or it fails in normal operation or performance test,
consult the OWON dealer responsible for such a business or the local office of OWON. If the
instrument is damaged due to transportation, keep the packing in a proper place and consult the
transportation department and the OWON dealer responsible for such business, who will provide
an instrument replacement or maintenance.
OWON HDS Series Handheld DSO & DMM 5-Input Connections
7
5.Input Connections
5.1 Input Connections
See the following figure 2:
figure 2
Description:
1. The power adapter is supplied for AC power supply and battery recharging.
2. Multimeter test lead.
3. Multimeter input jacks, including three circular banana jacks and tow square jacks.
The three circular jacks are used for voltage, current and resistance inputs, while
the two square jacks are used for capacitance inputs.
OWON HDS Series Handheld DSO & DMM 5-Input Connections
8
4. Oscilloscope probes.
5. Oscilloscope channel inputs: the upper one is for Channel 1 (CHI1), while the lower one is for
Channel 2 (CH2).
5.2 Description for Front Panel and Keys
See the following figure 3:
figure 3
Description:
1. Power adapter jack.
2. Serial port.
3. USB jack.
OWON HDS Series Handheld DSO & DMM 5-Input Connections
9
4. Backlight switch .
5. POWER: Power switch.
6. A: Multimeter current measurement key.
7. V: Multimeter voltage measurement key.
8. R: Multimeter resistance, triode, On/Off and capacitance measurement key.
9. OSC : Oscilloscope left-direction adjustment key.
10. OSC : Oscilloscope right-direction adjustment key.
11. OSC OPTION: Oscilloscope setting key.
z With the combination application of the four keys OSC , OSC , OSC and OSC , the
users can make the following settings circularly by pressing OSC OPTION. The settings
include: Voltage Unit Scale of Channel 1 (CH1 VOL); Voltage Unit Scale of Channel 2 (CH2
VOL); Primary Time base (TIME BASE), zero point position of channel 1(CH1 ZERO), zero
point position of channel 2(CH2 ZERO), trigger horizontal position (TIME) and trigger level
position (TRIG).
z When performing Waveform Calculation, the users can also adjust and calculate the Display
Multiplying Factor of waveform (CHM VOL) and the vertical display position (CHM ZERO).
z In cursor measurement mode, the users can adjust the positions of Cursor 1 (V1 or T1) and
Cursor 2 (V2 or T2).
12. OSC : Oscilloscope display downward adjustment key.
13. OSC : Oscilloscope display upward adjustment key.
14. OSC/DMM: Operation mode switching key between oscilloscope and multimeter.
15. AUTO SET:
z Under the Multimeter Mode, when performing the current or voltage measurement, you can
make a measurement switch between AC and DC with this key pressed; when performing the
resistance measurement, you can select resistance, diode, On/Off or capacitance measurement
circularly with this key.
z While this key is used for auto setting under the oscilloscope operation mode.
16. RUN/STOP: key for running or stopping the operation.
17. MENU : Choose the lower item on the menu list.
18. MENU: Show / Hide the menu
19. MENU : Choose the upper item on the menu list.
20. F1
F5: Switch or Adjust options for each menu.
21. the 5v output port with a frequency of 1 kHz as the test-signal.(only for the HDS1022M )
OWON HDS Series Handheld DSO & DMM 6-Using the Scope
10
6.Using the Scope
6.1 About this Chapter
This chapter provides a step-by-step introduction to the scope functions. The introduction does not
cover all of the capabilities of the scope functions but gives basic examples to show how to use the
menus and perform basic operations.
6.2 Power-Up the Oscilloscope
Connect oscilloscope to AC power via a power adapter as shown in Figure 1. (The oscilloscope
may still work with built-in Li-ion battery even without AC power supply)
Turn the oscilloscope on by pressing down the power on/off key POW.
The instrument then performs selfchecking after power on. A greeting window and a sentence
“press any key to continue……” will display on the screen when the system finishes selfchecking.
The users can press any key to enter the measuring function.
The oscilloscope is powered up in its last setup configuration.
6.3 Oscilloscope Operation Window
See the following figure 4:
figure 4: Oscilloscope Operation Window
OWON HDS Series Handheld DSO & DMM 6-Using the Scope
11
Description:
1. Battery electric quantity indicating symbols, including
, , and .
2. Auto measurement window 1, in which “f ”means frequency, “T” means cycle, “V” means
the average value, “Vp” the peak-peak value ,“Vk” the root-mean-square value,. “MAX” the
maximum amplitude value, “MIN” the minimum amplitude value, “VT” the Voltage value of
the waveforms flat top value, “VB” the Voltage value of the waveform’s flat base, “AMP”
the amplitude value, “OS” the overshoot value, “PS” the Preshoot value, “RT” the rise time
value, “FT” the fall time value, “NW” the +width value, “PW” the -Width value, “+D” the
+Duty value, “-D” the -Duty value, “PD” the DelayA
B value and “ND” the
DelayA
B value.
3. Auto measurement window 2.
4. The pointer indicates the horizontal triggering position.
5. This reading gives the Time Difference between the horizontal triggering position and the
screen centerline. It reads zero when the pointer is in the center of the screen.
6. The trigger state indicates the following information.
Auto: The oscilloscope is working in the automatic mode and displaying the waveform
under the non-trigger state.
Trig’d: The oscilloscope has detected a trigger and collecting the information generated
after the trigger.
Ready: All pre-triggered data have been captured and the oscilloscope has been ready to
receive trigger signals.
Scan: The oscilloscope can gather and display the waveform data continuously in scanning
mode.
Stop: The oscilloscope has stopped collecting the waveform data.
7. The green pointer shows the trigger voltage level.
8. A hidden-style menu: With the MENU key pressed, you can view or hide the menu.
9. Menu setting options: There are different setting options for different menus.
10. It reads the value of trigger voltage level.
11. The display shows the trigger signal source.
12. The reading gives the value of primary time base.
13. These graphics present the coupling modes of channel 2(CH2). The graphic “” indicates
AC, the graphic “” indicates DC.
14. This reading shows the vertical Voltage Unit Scale of CH2.
15. These graphics show the coupling mode of CH1, among which the graphic “” express
OWON HDS Series Handheld DSO & DMM 6-Using the Scope
12
indicates AC, the graphic “” indicates DC.
16. This reading shows the vertical Voltage Unit Scale of CH1.
17. The blue pointer gives the grounding datum point of the waveform on CH2, which is the zero
position of CH2. No display of this pointer indicates that the channel has not been opened.
18. OSC OPTION operation prompt: There are different prompts for different OSC OPTION
operations.
19. The red pointer gives the grounding datum point of the waveform on CH1, which is the zero
position of CH1. No display of this pointer indicates that the channel has not been opened.
20. Waveform display area. Red waveform represent CH1, blue waveform represent CH2.
6.4 Navigating a Menu
The following example shows how to use the tool’s menus to select a function, as shown in the
following figure.
1. Press the MENU key to display the Function Menu on the right of the screen and the
corresponding optional settings on the bottom. Press MENU again will hide the Function
Menu.
2. Press the MENU or MENU key to select different function menus.
3. Choose one key from F1 to F5 and press it to change function setting.
See the following figure 5:
figure 5: the Tool’s Menus
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74

OWON HDS1022M-N User manual

Category
Measuring, testing & control
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI