Dell PowerEdge T710 User guide

Type
User guide
Intel Xeon 5600 Series Processors—
Information Update
Important Information
Your system requires a BIOS and iDRAC firmware upgrade to support Intel
Xeon 5600 series processor (less than 130 W). You can download the BIOS and
iDRAC firmware for the Intel Xeon 5600 series processor at
support.dell.com
.
NOTE: A BIOS and iDRAC firmware update only supports a limited feature set of
the Intel Xeon 5600 series processor.
The following new Dell PowerEdge systems marked with the Roman Numeral
II on the chassis support the complete feature set of Intel Xeon 5600 series
processors:
R410
R510
R610
R710
T410
T610
T710
M610
M710
NOTE: The PowerEdge R410, T410, and R510 systems do not support 130 W
Intel Xeon 5600 series processors.
NOTE: The modular systems, PowerEdge M610 and M710, support the 130 W
Intel Xeon X5680 only in the 130 W processor category.
NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to
support the 130 W Intel Xeon 5600 series processors.
Mixing of Intel Xeon 5500 and 5600 series processors is not supported.
Systems with the Intel Xeon 5600 series processors support memory sparing.
2011 - 12 A02
Low Voltage Memory Modules (DDR3L DIMMs)
Intel Xeon 5600 series processors
support DDR3L DIMMs enabling a lower
operating voltage (1.35 V) that ensures memory power savings up to 20% per
DIMM. DDR3L memory is backward-compatible to Intel Xeon 5500 series and
operates at standard voltage (1.5 V) without any limitations.
Operating the system memory at a lower voltage may cause restrictions to
additional frequency and memory population capabilities. For example,
populating three memory modules per channel is not supported at 1.35 V.
Systems with
1.35 V DDR3L memory
operates the memory modules at 1.5 V
if any of the following conditions exist:
Intel Xeon 5500 series processors
Two 1333 MHz DIMMs per channel
A combination of both standard and low voltage memory modules
For information on the memory configuration guidelines, see your system’s
Hardware Owner’s Manual at support.dell.com/manuals.
NOTE: BIOS setup options allow the user to control frequency and voltage
configuration within allowable limits.
New BIOS Setup Options
Integrated Devices Screen
Option Description
SR-IOV-Global Enable
(
Disabled
default)
Enables/disables BIOS configuration of Single Root
I/O Virtualization (SR-IOV) devices.
NOTE: Applies to PowerEdge R410, R510, R610, R710, R910,
T410, T610, and T710 systems only.
Memory Settings Screen
Processor Settings Screen
Option Description
System Memory Voltage Displays the system memory voltage.
Memory Operating Voltage
(Auto Default)
Sets the system memory voltage selection.
Memory Operating Mode Displays the type of memory operation if a valid memory
configuration is installed. When set to Optimizer mode, the
memory controllers run independent of each other for
improved memory performance. When set to Mirror mode,
memory mirroring is enabled. When set to Advanced ECC
Mode, two controllers are joined in 128-bit mode running
multi-bit advanced ECC. The Spare mode option is present
on systems with the Intel Xeon 5600 series processors only.
Option Description
C1E (Enabled default) Sets the processor performance state to minimum
when the system is idle.
Intel QPI Bandwidth Priority
(Compute default)
Sets the bandwidth priority to compute or I/O.
Recommended for HPC applications.
Adjacent Cache Line Prefetch
(Enabled default)
Enables high utilization of sequential memory access.
NOTE: Disable this option for applications that require
high utilization of random memory access.
Hardware Prefetcher
(Enabled default)
Enables or disables the hardware prefetcher.
DCU Streamer Prefetcher
(Enabled default)
Enables Data Cache Unit streamer prefetcher.
Recommended for HPC applications.
Data Reuse
(Enabled default)
Enables or disables data reuse. Recommended
for HPC applications.
System Security Screen
New POST Messages
The following are the new POST messages for the Intel Xeon 5600 series
processors.
Option Description
Intel(R) TXT (Disabled
default)
Enables/disables Trusted Execution Technology. To enable
TXT, enable & activate VT & TPM with pre-boot
measurement.
Message Description
System Memory Size:
X.X GB, System Memory
Speed: XXX MHz,
Voltage: 1.5V or 1.35V
Displays the amount of system memory, system
memory speed, and current system memory
operating voltage.
This CPU power rating
is not supported
This message displays when either of the following
occurs:
The Intel Xeon 5600 130 W series processor is
detected on an old system board (systems not marked
with roman numeral II). For a list of the supported
systems, see Important Information.
The Intel Xeon X5677 130 W series quad-core
processor is detected on PowerEdge M610 and
M710.
Non-ECC DIMM detected
on DIMM XX
Displays when the system detects a non-ECC
memory module.
Enabling Dell BIOS Intelligent Turbo Mode
The Dell BIOS Intelligent Turbo Mode feature allows the operating system to set
the processor performance in the turbo mode. Based on the processor utilization,
this feature delays the processor turbo mode initiation for better power
management. When the turbo mode is enabled in the Processor Settings screen
of the system setup, the feature can be enabled or disabled using the following
BIOS setup options:
NOTE: The Dell BIOS Intelligent Turbo Mode is disabled when the turbo mode is
disabled in the processor system setup screen.
____________________
Information in this publication is subject to change without notice.
© 2010–2011 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is
strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc. Intel
®
and Xeon
®
are registered trademarks of Intel Corporation in the U.S. and other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade
names other than its own.
Setup Screen Field Field value Intelligent Turbo
Power Management CPU Power and
Performance Management
OS DBPM Enabled
Power Management CPU Power and
Performance Management
System DBPM Disabled
Power Management CPU Power and
Performance Management
Maximum
Performance
Disabled
Intel Xeon 5600
系列处理器—信息
更新
重要信息
系统需进行
BIOS
iDRAC
固件更新才能支持
Intel Xeon 5600
系列处理器
(小于
130 W
)。要下载适用于
Intel Xeon 5600
系列处理器的
BIOS
iDRAC
固件,请登录
support.dell.com
注:BIOS iDRAC 固件更新仅支持 Intel Xeon 5600 系列处理器的有限功能
组。
以下机箱上标有罗马数字“
II
”的新
Dell PowerEdge
系统支持
Intel Xeon
5600
系列处理器的完整功能组:
R410
R510
R610
R710
T410
T610
T710
M610
M710
注:PowerEdge R410T410 R510 系统不支持 130 W Intel Xeon 5600 系列处
理器。
注:模块化系统 PowerEdge M610 M710 仅支持 130 W 处理器类别中的 130
W Intel Xeon X5680
注:PowerEdge R610 M710 系统需使用特定散热器才能支持 130 W Intel
Xeon 5600 系列处理器。
不支持混合使用
Intel Xeon 5500
5600
系列处理器。
配有
Intel Xeon 5600
系列处理器的系统支持内存备用功能。
2011 12
A02
System Security
(系统安全保护)屏幕
新的
POST
信息
以下是启动
Intel Xeon 5600
系列处理器时出现的新的
POST
信息。
选项 说明
Intel(R) TXT
(默认为
Disabled [
已禁用
]
启用
/
禁用受信任的执行技术。要启用
TXT
,启用并激活
VT
TPM
,并进行预引导测量。
信息 说明
System Memory Size:
X.X GB, System Memory
Speed: XXX MHz,
Voltage: 1.5V or 1.35V
显示系统内存容量、系统内存速率以及当前系统
内存的操作电压。
This CPU power rating
is not supported
发生以下任一情形时,会显示此信息:
在旧主机板 (没有标罗马数字
II
”的系统)
上检测到
Intel Xeon 5600 130 W
系列处理器。
有关支持的系统的列表,请参阅重要信息。
PowerEdge M610
M710
上检测到
Intel
Xeon X5677 130 W
系列四核处理器。
Non-ECC DIMM detected
on DIMM XX
系统检测到非
ECC
内存模块时会显示此信息。
启用
Dell BIOS
智能
Turbo
模式
Dell BIOS
智能
Turbo
模式功能允许操作系统在
turbo
模式下设置处理器性能。
为实现更好的电源管理,该功能会根据处理器使用情况,延迟处理器
turbo
式的启动。如果在系统设置的
Processor Settings
(处理器设置)屏幕中启用了
turbo
模式,则可使用以下
BIOS
设置选项启用或禁用该功能:
注:如果在处理器系统设置屏幕中禁用了 turbo 模式,则会禁用 Dell BIOS 智能
Turbo 模式。
____________________
本出版物中的信息如有更改,恕不另行通知。
© 2010
2011 Dell Inc.
版权所有,翻印必究。
未经
Dell Inc.
书面许可,严禁以任何形式复制这些材料。
本文中使用的商标
Dell
DELL
徽标和
PowerEdge
Dell Inc.
的商标。
Intel
®
Xeon
®
Intel Corporation
在美国
和其它国家
/
地区的注册商标。
本出版物中可能使用其它商标和产品名称提及拥有相应商标和产品名称的实体或其制造的产品。
Dell Inc.
对其它公司的商标和产品名称不拥有任何所有权。
设置屏幕 字段 字段值 智能
Turbo
Power Management
(电源管理)
CPU Power and
Performance Management
CPU
电源和性能管理)
OS DBPM Enabled
(已启用)
Power Management
(电源管理)
CPU Power and
Performance Management
CPU
电源和性能管理)
System DBPM
(系统
DBPM
已禁用
Power Management
(电源管理)
CPU Power and
Performance Management
CPU
电源和性能管理)
Maximum
Performance
(最佳性能)
已禁用
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Dell PowerEdge T710 User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI