INSTALLATION INSTRUCTIONS FOR
CENTRAL MOTOR RESET MECHANISM (pre 2000 series)
1. Looking from front of unit, loosen the two bolts on the right side of motor mount.
2. Align slots on reset mechanism mounting bracket with loosened bolts and slide
mounting bracket under bolt heads but on top of base plate of motor.
3. Push reset mechanism guide block tight against motor base plate and retighten bolts
while holding in place.
4. Pull rod to check alignment with motor reset button.
SECTION A-A
1. LOOSEN BOLTS
REAR VIEW
FRONT VIEW
TOP VIEW
FILTER MOTOR REF.
2. SLIDE BRACKET
OVER MOTOR BASE &
UNDER BOLT HEADS.
3. HOLD GUIDE BLOCK
TIGHT AGAINST
MOTOR BASE WHILE
TIGHTENING BOLTS.
4. CHECK ALIGNMENT
FILTER MOTOR RESET
PULL HANDLE
MOTOR RESET MECHANISM
ASSEMBLY #023798
LABEL #024117
“FILTER MOTOR RESET
PULL HANDLE”
FILTER
PUMP
PULL ROD
RESET MECHANISM
SERVICE INSTRUCTIONS
www.keatingofchicago.com 1-800-KEATING