Harrington Welf-Air 10kVA Cube Installation guide

Type
Installation guide

Harrington Welf-Air 10kVA Cube is a compact and powerful generator designed for a variety of applications. It is powered by a Kubota engine and features a water-cooled system for efficient operation. The generator has a maximum power output of 10kVA and is capable of providing reliable power for various electrical devices and appliances. It is equipped with a 63 Amp plug and lead for easy electrical connection and has a low fuel shutdown to prevent air from entering the fuel system. The generator is also designed with a keyless stop/start system for added convenience.

Harrington Welf-Air 10kVA Cube is a compact and powerful generator designed for a variety of applications. It is powered by a Kubota engine and features a water-cooled system for efficient operation. The generator has a maximum power output of 10kVA and is capable of providing reliable power for various electrical devices and appliances. It is equipped with a 63 Amp plug and lead for easy electrical connection and has a low fuel shutdown to prevent air from entering the fuel system. The generator is also designed with a keyless stop/start system for added convenience.

Ravenstor Road
Wirksworth
Derbyshire
DE4 4FY
ENGLAND
Sales Tel:
+44 (0) 1629 824 284
Sales Fax: +44 (0) 1629 824 613
Website: www.hgigenerators.com
Installation Guide
Welf-Air Cube
10.0kVA Water Cooled Diesel Generator
Build No: WA100H
Publication: 498-1075
© Harrington Generators International Limited
All rights reserved. No part of this publication may be reproduced in any material form (including photography or storing in
any medium by electronic means or other) without the written permission of the copyright holder except in accordance with
the provisions of the Copyright, Designs and Patents Act 1988.
Applications for the copyright holders written permission to reproduce any part of this publication should be addressed to
Harrington Generators International Limited at the address above.
Any reference to trademarked product names used within this publication is owned by their respective companies.
Harrington Generators International Limited reserves the right to change the contents of this document without prior notice.
Change Control
Date Version Author Reason for change
May 17 Provisional MC Draft for Review by NC
May 17 A MC Updated and released following review
Harrington Generators International
498-1075Welf-Air 10kVA Cube
Contents
Contents
1.0 INSTALLATION ............................................................................................1
1.1 General ......................................................................................................1
1.2 Ventilation .................................................................................................1
1.3 Hot Air Outlet ............................................................................................1
1.5 Fixing Skids ..............................................................................................2
1.6 Connecting Hot Air Outlet .......................................................................2
1.7 Fixing Down ..............................................................................................2
1.8 Cabin’s Exhaust Outlet ............................................................................2
1.9 Connecting the Exhaust ..........................................................................2
1.10 Electrical Connection ..............................................................................2
1.11 Clearance Space ......................................................................................2
2.0 CONTACT ....................................................................................................2
3.0 DRAWINGS ..................................................................................................3
3.1 General Arrangement ................................................................................3
3.2 Installation Drawing ..................................................................................5
4.0 MANUFACTURER’S SERVICE AND USER GUIDE LINKS .......................6
4.1 Kubota Engine Operators Manuals........................................................6
4.2 Deep Sea Electonics 3110 User Guide ...................................................6
4.3 Sincro SK160 User Manual .....................................................................6
Harrington Generators International
498-1075 Welf-Air 10kVA Cube
Harrington Generators International
498-1075Welf-Air 10kVA Cube
Welf-Air
WA100H
1500 RPM
Diesel Generator
Harrington Generators International
1 498-1075Welf-Air 10kVA Cube
Installation Guide
1.0 Installation
Installation of the generator is to be made by quali ed
personnel in accordance with the appropriate
regulations e.g., Electricity Safety, Quality and
Continuity Regulations 2002 (S.I. 2002/2665), and the
following Electrical Safety regulations:
I.E.E Regulations 17th Edition (BS 7671:2008)
Health and Safety Executive Publications GS27
Protection Against Electric Shock
Health and Safety Executive Publications GS24
Electricity On Construction Sites
Health and Safety Executive Publications PM53
Emergency Private Generation
1.1 General
The Welf-Air Compact range of generators has
been designed by HGI to perform exceptionally
well in the con nes of a small cabin. New type
mounts are used in the set, so that vibration is
kept to a minimum, when placed on a cabin oor.
Two silencers, special sound insulation, water
cooled engines and careful canopy design keep
noise level to an absolute minimum.
The integral base mounted tank gives many
hours of continuous operation, is easy to re ll and
has a low fuel shutdown to stop air entering the
fuel system. The access door is a lift-off type to
save space. The keyless stop/ start means no
lost keys.
The Welf-Air Compact has long service intervals
and its service items are on the outward facing
side, thus making servicing easy and economic.
Hot air exits the top quarter of the end panel
opposite the air inlet panel. The set is designed to
be pushed up to the right and against a cabin
wall, which should have a louvre panel cut into it.
Other louvres need to be made in the cabin to
allow cool air to enter the generator compartment.
The generators exhaust exits vertically. An
extension tube, brackets and heat wrap are
supplied. It is important that the heat wrap is
tted so that operatives do not burn themselves.
These instructions explain the installation of Welf-
Air Compact generators. Read completely before
installing.
The following notes are for the guidance of cabin
manufacturers and customers. Do not hesitate
to contact HGI Ltd for further advise and help.
The generators are supplied complete with:-
1. Approx 1 metre of exible exhaust pipe, two
exhaust pipe clamps and thermal insulation wrap.
2. A 63 Amp plug and lead to electrically connect to
the set.
3. Two oor brackets that secure one side of the
generator.
4. Quick Start Guides with Manuals available for
download.
5. Laminated care sheets.
In essence, to install the generator:
1. Prepare the cabin, including air exits, louvres,
brackets and exhaust exit.
2. Fork truck the generator into position.
3. Push the set against the skid brackets and push
against the hot air outlet cut into the
4. cabin.
5. Bolt front skids down.
6. Clamp exible to exhaust and cabin exhaust
outlet.
7. Connect cabin to the 63 Amp socket.
1.2 Ventilation
Adequate sized louvre panels should be built into the
cabin doors and cabin walls for generator ventilation
purposes.
NOTICE
Care must be taken to ensure that the machine
does not circulate its own exhaust fumes, the
machine must be able to take in cold air in order to
perform correctly.
1.3 Hot Air Outlet
A rectangular hole should be cut into the cabin wall
to allow the generator hot air to escape. The size
is 690mm wide by 973.5mm high and is positioned
112mm up from the top of the inside cabin oor (see
drawing PD901-908).
If at all possible, nish the interior of the cabins hot air
outlet with at ush metal so that the generators foam
seal has a suitable surface to seal against.
The outside nish is the responsibility of the cabin
manufacturer but should take into account:
• Weather ingress
Animals, pests and vermin
Health & Safety considerations
Harrington Generators International
498-1075 2 Welf-Air 10kVA Cube
Installation Guide
Security and vandalism
Allow a 210mm clearance to access the electrical
output socket at the front of the generator.
1.4 Positioning Generator
When you look into the cabins generator compart-
ment, the generator is positioned up against
the right hand cabin wall. The hot air escape
should be cut into the right hand wall.
1.5 Fixing Skids
The skids are tted ush front and back to the
generator and at 170mm from the sides of the
generator.
The skids are 200mm wide by 70mm high (see
drawing WG-WA100H).
1.6 Connecting Hot Air Outlet
The hot air outlet is on the right hand side of the set
which should be pushed up to the right hand cabin
wall, to within 25mm of the cabin wall. The foam seal
(supplied tted to the generator) around the hot air
exit will squash and act as an air seal. It does not
need to be perfectly air tight (see drawing PD901-
908)
Alternative arrangements for hot air outlet using
plenum connection to exit louvres can be provided by
HGI for installation into buildings.
1.7 Fixing Down
Fixing down is via the bolt holes in the skid pods on
the base of the generator. The xing down holes
are located 57.5mm from front and back and are are
675mm apart on the same skid and 560mm distant
from the corresponding hole on the second skid. The
See drawings WG-WA100H.
The generator, when being xed down using the
standard foam seal arrangement, will have the right
hand side xing down hole approx 300mm from the
wall (see PD901-908).
The type of xing will depend on the oor type,
thickness of oor material etc.
1.8 Cabin’s Exhaust Outlet
The exhaust pipe comes out of the top of the Welf-
Air generators canopy and is then turned through 90
degrees so that it comes out of the side wall of the
cabin. This is done so there are no problems with
water entry through the roof or stacking the cabins on
top of each other. The welded exit pipe can be cut
at an angle outside to stop rain getting in.
1.9 Connecting the Exhaust
Using the exible pipe and clamps supplied,
connect the exible pipe to the generator exhaust
stack and to the cabins exhaust outlet (see drawing
PD901-908).
Finally use the thermal insulating bandage supplied
to wrap around the exible exhaust pipe to insulate
it and protect people from touching the hot pipe. Use
steel wire ties or similar at each end to prevent the
bandage from becoming unwrapped.
NOTICE
Care must be taken to make a gas tight seal
when connecting the exhaust.
1.10 Electrical Connection
A 63 amp BS4343 socket is tted on the generator
adjacent to the fuel ll and below the socket panel.
This single socket supplies all the generators power
for the cabin. The additional sockets are for auxiliary
use for lights, tools or other cabins.
1.11 Clearance Space
The generators need to occupy a clear space within
the cabin compartment for ventilation and to allow
access for refuelling and service.
Cables, water pipes, pumps, tanks, waste and other
items should be located away from the generator.
2.0 Contact
If you are in any doubt or have any concerns about
the safe installation of the generator then please
consult with your service depot or contact HGI:
Technical Helpline: 01629 821 614
General Enquiries: 01629 824 284
Harrington Generators International
3 498-1075Welf-Air 10kVA Cube
Drawings
3.0 Drawings
3.1 General Arrangement
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
C
Checked
Material Finish
Title Drg No.
For insert & fabrication specifications refer to PD999-001
02.12.14
10kVA Welfair Cube
General Arrangement
WG-WA100H
A
M.A
02.12.14
B
N.N
28.07.15
C
R.W
19.05.16
D
R.W
27.04.17
E
R.W
19.05.17
WG-WA100H
Item
Description
Item
Pt No.
Item
Material
Sht
no.
Weight (kg)
1 /2
3D views are for illustration only.
495 kg max.
Cool Air
Inlet
Cool Air
Inlet
Fuel Filler
Neck
Hot Air
Outlet
Hot Air
Outlet
Hot Air
Outlet
2.5 Tonne
Lifting Eye Exhaust Outlet
Radiator
Access Cover
Forklift
Pods
Lift-off
Service Door
Hinged Control
Panel Door
Terminal
Cover
Hinged Access
Panel for Alternator
& Battery
Harrington Generators International
498-1075 4 Welf-Air 10kVA Cube
Drawings
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
C
Checked
Material Finish
Title Drg No.
For insert & fabrication specifications refer to PD999-001
02.12.14
10kVA Welfair Cube
General Arrangement
WG-WA100H
A
M.A
02.12.14
B
N.N
28.07.15
C
R.W
19.05.16
D
R.W
27.04.17
E
R.W
19.05.17
WG-WA100H
Item
Description
Item
Pt No.
Item
Material
Sht
no.
Weight (kg)
2 /2
3D views are for illustration only.
270.0 560.0
57.5
675.0
Cover Plate
over 32A 230V
socket
4 off -
Ø12.0 Bolt-down Holes
Lift-off Access
Door
790.0
844.4 max.
1283.0 max.
1151.0
70.0
170.0
200.0 200.0
560.0
360.0
1100.0
1104.6
89.0
84.0
1243.5
Harrington Generators International
5 498-1075Welf-Air 10kVA Cube
Drawings
3.2 Installation Drawing
A-A
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
C
Checked
Material Finish
Title Drg No.
For insert & fabrication specifications refer to PD999-001
11.05.17
WA100H 10kVA Welfair
Installation Drawing
PD901-908
A
R.W
11.05.17
B
R.W
19.05.17
PD901-908
Item
Description
Item
Pt No.
Item
Material
Sht
no.
Weight (kg)
1 /1
A
A
3D views are for illustration only.
Front
Face
Rear
Face
Cabin Floor
Foam seal
112.0
973.5
450.0 approx.
690.0
300.0560.0457.5 675.0
Hot Air
Outlet
Internal Dimensions
of Foam Seal
690.0 450.0 approx.
Cabin Internal Wall
112.0973.5
Air inlet open area
required in cabin
is 0.087m²
Air outlet open area
required in cabin
is 0.132m²
Note:
Louvres to be kept clear from obstruction
inside & outside
Foam seal
for access
for access
489 approx.
114.0
1243.5
Harrington Generators International
498-1075 6 Welf-Air 10kVA Cube
Manufacturer’s Service and User Guides
4.0 Manufacturers Service and User Guide Links
Every effort is made to ensure that the manufacturer’s user and service guides contained in this manual are the
latest available at the time of publication. If in doubt about the recency of the documents then please contact the
manufacturer or visit their website for the latest information.
4.1 Kubota Engine Operators Manuals
- http://www.kubota.co.uk/after-sales-support/publication/
4.2 Deep Sea Electonics 3110 User Guide
- http://www.deepseaplc.com
4.3 Sincro SK160 User Manual
- http://www.sogagroup.com/
If you are still unsure then please contact HGI Technical Helpline: +44 (0) 1629 821 614 or 821 652
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Harrington Welf-Air 10kVA Cube Installation guide

Type
Installation guide

Harrington Welf-Air 10kVA Cube is a compact and powerful generator designed for a variety of applications. It is powered by a Kubota engine and features a water-cooled system for efficient operation. The generator has a maximum power output of 10kVA and is capable of providing reliable power for various electrical devices and appliances. It is equipped with a 63 Amp plug and lead for easy electrical connection and has a low fuel shutdown to prevent air from entering the fuel system. The generator is also designed with a keyless stop/start system for added convenience.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI