Vivax cool ACP-24CH70GEEO User manual

Category
Split-system air conditioners
Type
User manual
ACP-24CH70GEEO
Service
manual
ENG
RoHS
NNO-1/09
COOLING HEATING
22000 24000
05420532
05130513
6.416.41
tinU roodnI fo ledoM
Fan Motor Speed (r/min)
(SH/H/M/L)
)W( rotoM naF fo tuptuO
)W( retaeH fo tupnI
Fan Motor Capacitor (μ)F
)A(ALR rotoM naF
epyT naF
Diameter-Length (mm)
rotaropavE
Pipe Diameter (mm)
)mm(paG niF-woR
Coil length (l) x height (H) x coil
width (L)
Swing Motor Model
Output of Swing Motor (W)
Fuse (A)
Sound Pressure Level dB (A)
(SH/H/M/L)
Sound Power Level dB (A)
(SH/H/M/L)
Dimension (W/H/D) ( mm)
Dimension of Package (L/W/H) (
mm)
Net Weight /Gross Weight (kg)
Air Flow Volume (m3/h) (SH/H/M/L)
Dehumidifying Volume (l/h)
EER / C.O.P (W/W)
Energy Class
Total Capacity (W/Btu/h)
Power Input (W)
Rated Input (W)
Rated Current (A)
Model
Function
Rated Voltage
Rated Frequency
Product Code
2.0
2.74/2.87
/
ACP-24CH70GEEO
220-240V
50 Hz
950/800/700/600
CA16300472
35
/
2.5
Indoor
unit
Cool1250/1100/950/800
Heat1300/1150/1000/850
0.31
Cross flow fan
Φ98X 765
Aluminum fin-copper tube
Φ7
2-1.5
765X342.9X25.4
MP35XX
1007X315X219
1076X398X328
15.5/20.5
2.5
PCB 3.15A
46/43/40/35
56/53/50/45
ACP-24CH70GEEO
ACP-24CH70GEEO
CA155W2742
Hitachi
SHV33ZC1-S
rotary
60
10.1
2175
BUILT IN
Capillary
Capacitor
-7T48
Aluminum fin-copper tube
Φ7.94
2-1.4
853X660X38.1
690
60
0.56
3.5
3200
Axial fan
Φ520
/
T1
I
IP24
2.5
0.6
57
67
955 X700X396
1029X458X750
56/61
R22/2.15
4
50
Liquid Pipe (mm) Φ6
Gas Pipe (mm) Φ16
Height (m) 10
Length (m) 25
Connectio
n
Pipe
Length (m)
Gas additional charge(g/m)
Outer Diameter
Max Distance
Model of Outdoor Unit
Compressor Manufacturer/trademark
Compressor Model
Compressor Type
Product Code
L.R.A. (A)
Compressor RLA(A)
Compressor Power Input(W)
Overload Protector
Throttling Method
Starting Method
Working Temp Range ()
Condenser
Pipe Diameter (mm)
Rows-Fin Gap(mm)
Coil length (l) x height (H) x coil width (L)
Fan Motor Speed (rpm)
Output of Fan Motor (W )
Fan Motor RLA(A)
Fan Motor Capacitor (μF)
Air Flow Volume of Outdoor Unit(m3/h)
Permissible Excessive Operating Pressure for
the Suction Side(MPa)
Fan Type
Fan Diameter (mm)
Defrosting Method
Climate Type
Net Weight /Gross Weight (kg)
Refrigerant Charge (kg)
Outdoor
unit
Sound Pressure Level dB (A) (H/M/L)
Sound Power Level dB (A) (H/M/L)
Dimension (W/H/D) ( mm)
Dimension of Package (L/W/H)( mm)
Isolation
Moisture Protection
Permissible Excessive Operating Pressure for
the Discharge Side(MPa)
The above data is subject to change without notice. Please refer to the nameplate of the unit.
ACP-24CH70GEEO
CA155W2740
ihcatiH
SHV33ZC1-S
yrator
06
1.01
5712
NI TLIUB
yrallipaC
Capacitor
-7 T48
Aluminum fin-copper tube
Φ7.94
2-1.4
853X660X38.1
690
60
0.56
3.5
3200
Axial fan
Φ520
/
T1
I
IP24
2.5
0.6
57
67
955 X700X396
1029X458X750
56/61
R22/2.15
4
50
Liquid Pipe (mm) Φ6
Gas Pipe (mm) Φ16
Height (m) 10
Length (m) 25
Connectio
n Pipe
Length (m)
Gas additional charge(g/m)
Outer Diameter
Max Distance
Model of Outdoor Unit
Compressor Manufacturer/trademark
Compressor Model
Compressor Type
Product Code
L.R.A. (A)
Compressor RLA(A)
Compressor Power Input(W)
Overload Protector
Throttling Method
Starting Method
Working Temp Range ()
Condenser
Pipe Diameter (mm)
Rows-Fin Gap(mm)
Coil length (l) x height (H) x coil width (L)
Fan Motor Speed (rpm)
Output of Fan Motor (W)
Fan Motor RLA(A)
Fan Motor Capacitor (μF)
Air Flow Volume of Outdoor Unit(m3/h)
Permissible Excessive Operating Pressure for
the Suction Side(MPa)
Fan Type
Fan Diameter (mm)
Defrosting Method
Climate Type
Net Weight /Gross Weight (kg)
Refrigerant Charge (kg)
Outdoor
unit
Sound Pressure Level dB (A) (H/M/L)
Sound Power Level dB (A) (H/M/L)
Dimension (W/H/D) ( mm)
Dimension of Package (L/W/H)( mm)
Isolation
Moisture Protection
Permissible Excessive Operating Pressure for
the Discharge Side(MPa)
The above data is subject to change without notice. Please refer to the nameplate of the unit.
Part name
Part name
3
Indoor unit
Outdoor unit
Front Panel
Air in
Power cord
Filter Guide louver
Air out
Remote Controller
Wall Pipe
Wrapping Tape
Heat
Cooling
Set Temp
Run
DRY LED displayer
Air in
Air out
epip noitcennoC
Drainage hose
Tube exit
Air inlet
Rear View
Right
Left
Ceiling
Wall-Mounting Plate
05K 07K 09K
12K
18K
24K
05K
07K
09K
12K
18K
24K
W
D
H
QR S
MODEL W( ) H( ) D( ) Q( ) R( ) S( )
790 265 170 36 605 149
845 275 180 130 542 173
940 298 200 54 694 192
1007 315 219 138 685 184
4.1 Outline and installation dimensions of indoor unit
4Outline and installation dimension
Outline and installation dimension
24K Outdoor unit
Bolt
Nut
Wrench
Over 60cm
revO mc06
revO mc06
mc06revO
955
560
007
891 341
396
463
ACP-24CH70GEEO
PCB function manual and operation method
66
66
6PCB function manual and operation method
6.1 ¿ØÖÆÆ÷¹¦ÄÜÊÖ²á 1
Function Manual
Basic functions (the centigrade is used in the following function manual. If there will be Fahrenheit degree,that will
be Tf=TcX1.8+32).
1. Temperature Parameters
ƹIndoor preset temperature (
T
preset)
ƹIndoor ambient temperature (
T
amb.)
2. Basic Functions
Once energized, the compressor shall never be restarted except 3-min interval at least. For the first energization, if the
unit with memory function is off before power failure, the compressor can be restarted without 3-min delay. But if the unit
is at ON status before power failure, the compressor shall be restarted with 3-min delay. Once started, the compressor
won't stop within 6 min with the change of room temp.
˄˄1˅Cooling mode
ķCooling conditions and process
When Tamb. Tpreset+1ć, the unit will run in cooling mode. In this case, the compressor and the outdoor fan run and
the indoor fan runs at setting speed.
When Tamb. Tpreset-1ć, the compressor and the outdoor fan will stop while the indoor fan will run at setting speed.
When Tpreset-1ć˘Tamb. ˘Tpreset+1ć, the unit will maintain its previous running state.
In this mode, the four-way valve is de-energizing, and setting temperature range is 16̚30ć. Running and cooling
marks and setting temperature are displayed.
ĸProtection
ƹAntifreezing potection
If it is detected that the system is in antifreezing protection, the compressor and the outdoor fan will stop running, and
the indoor fan will run at setting speed. If the antifreezing protection is released and the compressor has been stopped
for 3 min, the unit will resume its previous running state.
T
preset
+1
T
preset
-1
Compressor
Outdoor fan
Indoor fan Preset speed
Run
T
amb
Stop
Stop cooling
Start cooling
Original operating status
6 min. 3 min. 6 min.
During antifreeze protection
3 min.
Stop
Run
Preset speed
Compressor
Outdoor fan
Indoor fan
35
Overcurrent Protection(applicable to some models)
If it is detected that the system amperage exceeds the specified value in 3s successively, the outdoor unit will enter into
the state that only the fan is running. If the overcurrent protection is released, the complete unit will resume its previous
running state. If 6 times of protection successively occur (if the compressor has been running over 6mins continuously,
the protection times will be cleared), the complete unit will stop except the indoor fan is running. In this case, the unit can
be normally restarted only after turning off the unit by remote controller. The nixie tube displays error code E5 and the
running LED blinks (pauses 3s and blinks 5s).
2Dry Mode
Dry Conditions and Process
When Tamb. Tpreset+2 , the unit will run in dry and cooling mode. In this case the compressor and outdoor fan will
run and the indoor fan will run at low speed.
When Tamb. Tpreset-2 , the compressor and the outdoor fan will stop working and the indoor fan will run at low
speed.
In this mode, the four-way valve is de-energizing, and setting temperature range is 16 30 . Running and cooling
marks and setting temperature are displayed.
Protection
Antifreezing potection
If antifreezing protection of the system is detected in dry and cooling mode, the compressor and the outdoor fan will stop
running and the indoor fan will run at low speed. When the antifreezing protection is released and the compressor has
been stopped for 3 min, the complete unit will resume its previous running state. Upon the condition that the compresso
r
runs for 6 min and stops for 4 min is met and antifreezing protection is detected, the compressor and the outdoor fan will
stop running and the indoor fan will run at low speed. When the antifreezing protection is released and the compressor
has been stopped for 4 min, the complete unit will resume its previous running state.
Other protection
Other protections are the same as those in cooling mode.
3 Heating mode (cooling only unit is not available)
Heating conditions and process
When Tamb. Tpreset+2 , the unit will run in heating mode. In this case, the four-way valve, the compressor and the
outdoor fan will run simultaneously. The indoor fan will delay at most 2mins to run.
When Tamb≥ Tpreset+4 , the compressor and the outdoor fan will stop while the four-way valve will keep energizing
T
preset
+2
T
preset
-2
T
amb
Compressor
Outdoor fan
Indoor fan
Cooling
Dry
Stop
6 min
.
6 min
.
4 min. 4 min.
low speed
Run Stop
When Tpreset-2 ≤Tamb.≤Tpreset+2 , it runs with dry, and indoor fan motor runs with low speed, the compressor and
outdoor fan motor stop to run after they run 6min, and turn on them again 4min later, the dry process runs regarding to
above cycle.
36
and the indoor fan will blow residual heat.
When Tpreset +2 T amb. T
preset +4 , the unit will maintain its previous running state.
Under this mode, the four-way valve is energized, and setting temperature range is 16 30 . The displayer will displa
y
running and heating marks and setting temperature.
Defrosting Conditions and Process
The unit with intelligent defrosting function can defrost according to frosting conditions. Dual8 displays H1.
Protection Function
High Temp Resistant Protection
If it is detected that the evaporator tube temperature is superheating, the outdoor fan will stop working. When the tube
temperature resumes to normal condition, the outdoor fan will resume running.
Noise Silencing Protection
If the unit is stopped by pressing ON/OFF or during switchover of modes, the reversing valve will be stopped after 2 min.
Overcurrent Protection
This protection is the same as that in cooling mode (but indoor fan will blow residual heat).
4Fan mode
In this mode, indoor fan runs at setting speed, and the compressor, the outdoor fan, the four-way valve and the electric
heating tube (will) stop running. In this mode, temperature setting range is 16 30? . Displayer displays running marks
and the setting temperature.
5 Auto Mode
In this mode, the air conditioner will automatically select its running mode (cooling, heating or fan) with the change of
ambient temperature. The displayer will display the running marks, actual running mode mark and setting temperature.
There is 30s delay protection for mode switching. Protection functions are the same as those in any other mode.
3 Other Control
1Timer function
The mainboard combines general timer and clock timer functions. Timer functions are selected by equipping remote
controller with different functions.
General Timer
Timer ON can be set under off state of unit. If timer ON reaches, the controller will run under previous setting mode.
Timing interval is 0.5hr and the setting range is 0.5-24hr.
Timer OFF can be set under on state of unit. If timer OFF reaches, the unit is turned off. Timing interval is 0.5hr within
the range of 0.5-24hr.
Tse t
Tse t
Compressor
Outer fan
Inner fan
Reversal valve
Running Stop
Stop heating
Original running state
Start heating
Tamb.
6Min. 3Min. 6Min.
2Min. Setting
fan speed 2Min. Setting
fan speed
Clock Timer
If timer on is set under running state of unit, the system will continue running. If timer on is set under off state of unit, the
system will run in presetting mode when timer on reaches.
If timer off is set under off state of unit, the system will keep standby state. If timer off is set under on state of unit, the
system will stop running when timer off reaches.
Timer Change
If the system is under timer state, the unit can be turned on/off by ON/OFF button of remote controller. Timing can also
be reset and then the system runs according to the final setting.
If timer on and timer off is set at the same time under running state of system, the system will keep current running state
till timer off reaches and then it will stop running.
If timer on and timer off are set at the same time under off state of system, the system will keep stopping till timer on
reaches and then it will start running.
In the future, the system will run in presetting mode when timer on reaches and stop when timer off reaches every day. I
f
timer on and timer off have the same setting, timer off is prevails.
2 Auto Button
If press this button, the system will run in auto mode, and the indoor fan motor will run at auto speed; meanwhile, the
swing motor will be running. Repress this button to turn off the unit.
3 Buzzer
Upon energization or operation, the buzzer will give out a beep.
4 Sleep Function
The mode can provide different selection of the setting temperature curve for sleeping.
5 Turbo Function
This function can be set in cooling or heating mode.
6Dry Function
This function can be set in cooling or dry mode.
7 Automatic Control of Fan Speed
In this mode, the indoor fan will automatically select high, medium or low speed with the change of ambient temperature.
8Up & Down Swing
A
fter energization, up & Down swing motor will rotate guide louver anticlockwise to position 0 to close air outlet. After
turning on the unit, if swing function has not been set, up & down guide louver will clockwise turn to position D in heating
mode, or clockwise turn to level position L in other modes.
If the unit is turned on with swing function setting, the guide louver will swing between L and D.
There are 7 kinds of swing states of guide louver: There are position L, A, B, C, D, and it swings
and stops between L and D ( angle between L and D is equiangular).
Upon stop of unit, the guide louver will close to position O. Swing action is valid only when swing
command is set and indoor fan is running.
Note: If the position is set between L and B, A and C or B and D by remote controller, the guide
louver will swing between L and D.
L
A
B
C
D
O(0°)
38
9Display
Running mark and Mode mark
Upon energization, the unit will display all marks. Under standby state, running indicating mark is displayed in red. If the
unit is started by remote controller, running indicating mark gives off light; meanwhile, the current setting running mode
mark will be displayed(mode LED: cooling, heating and dry mode). If the light button is turned off, all marks display will
be closed.
Dual-8 Display
10 Locked protection to PG motor
When starting the fan, if motor’s rotational speed is slow for a period of time, the unit will display Locked and stop
running to avoid auto protection for motor. If the unit is on currently, error code H6 will be displayed by the Dual-8
Display. If the unit is off currently, this locked malfunction information won’t be displayed.
11 Power-off memory
Memory content includes mode, up&down swing, light, setting temp and setting fan speed.
Upon power failure, the unit after power recovery will automatically start to run according to memory content. The
system, last remote-control command without timer setting, will memorize the last remote-control signal and run
according to it. If the last remote-control command has general timer function and the system is de-energized before
setting time, the system will memorize the last timer function in remote controller command after re-energization and
time will be recalculated. If there is function in the last remote controller command but setting time has reached, the
system will act as timer on/off setting before de-energization. After re-energization, the system memorizes the running
states before power failure without timer action. Clock timer can not be memorized.
4 Special functions
1Health function
When the indoor fan motor is running, the Health function is set by pressing remote controller (If there is no Health
button on the remote controller, the Health function opening is defaulted).
2 I Feel function
If the remote controller receives the I Feel order, the controller will work at the ambient temperature value which is sent
by remote controller (Except the defrosting and anti-cool wind, which still adopts the sampling value of AC itself ambient
temperature sensor), the remote controller will send ambient temperature value to controller at intervals. If the controller
hasn’t received the ambient temperature value from the remote controller for long time, then it will run accroding to the
current ambient temperature of AC. If the function has not been set, the ambient temperature will adopt the sensor
sampling value of AC itself. If power off happens, this function will not be memorized.
The current setting temperature will be displayed if the user sets setting temperature display;
The ambient temperature display
status switched from other status will keep 5s and then setting temperature display starts. For the first startup of the unit,setting
temperature display is a default. C5 will be displayed for jumper cap malfunction, F1 for ambient temperature sensor malfunction
and F2 for internal tube temperature sensor malfunction; H1 will be displayed during defrosting and H6 during PG motor lock.
39
3Temperature sensor malfunction detection
F1 is displayed when the indoor ambient sensor malfunction is detected and F2 is displayed when the indoor tube sensor
malfunction.
LIGHT button
LIGHT
ON/OFF button
Signal transmitter
AUTO
COOL
DRY
FAN
HEAT
MODE button
SLEEP button
SLEEP
FAN button
FAN
CLOCK button
CLOCK
Operation of remote controller
Names and functions of buttons
Note: Be sure that there are no obstructions between receiver and remote controller;
Don't drop or throw the remote control; Don't spill any liquid on the remote controller;
Don't put the remote controller directly in sunlight or hot environments.
Press SLEEP button into SLEEP operation.
Press SLEEP button again to cancel SLEEP.
This function only can be used in COOL ,
HEAT (applicable to heat pump unit) or DRY
mode , to maintain the most comfortable
temperature for you.
ƽ
ƽEvery press of FAN button changes the
fan speed in the following order:
AUTO
Low speed Medium speed
High speed
Note:In Dry mode, the fan speed is not
adjustable, and low fan speed is forced.
Pressing CLOCK button, the icon blinks.
During 5 seconds blinking, pressing + or -
button adjusts present time.Holding down
either button above 2 seconds increases
or decreases the time by 1 minute every
0.5 second. If you are still pressing the
button after 10 minutes increased or
decreased, the time will be changed by
10 minutes every 0.5 second.During
blinking, press the CLOCK button again,
the icon will be constantly displayed
and it indicates that clock setting has been
finished.
ƽ
Pressing LIGHT button turns on/off the
display 's light. If LIGHT is tunrned on ,
is displayed . If LIGHT is turned off,
the icon disappears.
ƽ
Remote controller
Press ON/OFF button to start the unit
operation.Press the button again to stop
the unit operation.Upon start or stop of
operation, TIMER settingwon't be canceled
but SLEEP setting.
ƽ
Each time you press the button,a mode
is selected in a sequence that goes from
AUTO,COOL,DRY, FAN,and HEAT* as the
following:
ƽ
*Note:Only for models with heating function.
Pressing this button, you can select displaying
the indoor setting temperature or indoor
ambient temperature.When the indoor unit
firstly power on, it will display the setting
temperature, if the temperature's displaying
status is changed from other status to" ",
it will displays the ambient temperature, 5s later
or within 5s, if it receives other remote control
signal, it will return to display the setting
temperature. If the users haven't set up the
temperature displaying status, it will
display the setting temperature.
Remote control
BLOW button
BLOW
TEMP button
TEMP
+ button
+
- button
-
TURBO button
TURBO
After powered on, the setting temperature
displaying is defaulted, (according to
customers requirements to display, if
there is no requirement , it will default
to display the setting temperature
and there is no icon displayed on wireless
remote control). After pressing this button,
(When displaying ) , it will display
setting temperature; (when displaying )
it will display indoor ambient temperature,
current displaying status will not be
changed. When it current displays indoor
ambient temperature, if it received other
remote controller's signal, it will display
setting temperature. 5s later, it will turn back
to display the ambient temperature.
(This function is applicable to some models)
(This function is applicable to some models)
Pressing + button increases the set
temperature. Holding down button
above 2 seconds rapidly increases set
temperature. In AUTO mode,set
temperature is not adjustable.
Pressing-button decreases the set
temperature.Holding down this button
above 2 seconds rapidly decreases
set temperature. In AUTO mode,set
temperature is not adjustable.
Pressing BLOW button in COOL or DRY
mode, "BLOW "is displayed and the
indoor fan continues operation for 10
minutes in order to dry the indoor unit
even though you have turned off the unit.
After energization, BLOW OFF is defaulted.
BLOW is not available in AUTO, FAN or
HEAT mode.
Pressing TURBO button in COOL or
HEAT mode turns on/off Turbo function.
After TURBO function is set , its icon is
displayed. When switching operation
mode or changing fan speed, this
function will be canceled automatically.
SWING UP AND DOWN button
TIMER ON
TIMER ON button
TIMER OFF button
TIMER OFF
Remote controller
indicates the guide louver swings as:
Names and functions of buttons
Notice: The remote controller is universal and it could be used for many units. Some
buttons on this control are not applicable to this unit.
ƽ
Pressing TIMER ON button, "ON" blinks
and disappears. Within 5 seconds,
every press of + or - button increases or
decreases the ON time setting by 1 minutes.
Holding down either button above 2.5 seconds
rapidly changes the time setting by 1 minute
and then by 10 minutes . Within 5 seconds
after setting, press TIMER ON to confirm.
To cancel the TIMER ON operation,
press TIMER ON buton.
ƽPress TIMER OFF button to set TIMER OFF.
The setting method is the same as TIMER
ON.
Every press of button changes
swing angle in the following order:
This remote controller is universal . If any
command , or is sent out,
the unit will carry out the command as:
If the unit is turned off during swing operation,
the louver will stop at present position.
Introduction for special function
Guide for operation- General operation
Guide for operation- Optional operation
1. Press On/Off button to start or stop operation.(Note:When it is powered
off, the guide louver of main unit will close automatically.)
2. Press MODE button to select desired running mode, or press COOL or
HEAT button into the corresponding operation directly.
3. Pressing +or - button to set the desired temperature. (It is unnecessary
to set the temperature in AUTO mode.)
4. Press FAN button to set fan speed among AUTO FAN, LOW, MID
and HIGH.
5. Press button to select the swing method.
1. Press SLEEP button to set sleep.
2. Press TIMER ON or TIMER OFF button to set the scheduled timer on or
timer off.
3. Press LIGHT button to switch On or Off the display on the main unit.
(This function may be not available for some models).
4. Press TURBO button to switch ON and OFF.
About BLOW function
About BLOW function
About AUTO RUN
This function indicates the fan will continue to blow after the unit is stopped to remove moisture
on evaporator of indoor unit to avoind mould.
1. Having set BLOW function on: After turning off the unit by pressing ON/OFF button indoor
fan will continue running for about 10 min at low speed. In this period, press Blow button
to stop indoor fan directly.
2. Having set BLOW function off: After turning off the unit by pressing ON/OFF button, the
complete unit will stop directl and the BLOW function is not operated.
When AUTO RUN mode is selected, the set temperature will not be displayed on the LCD.
the unit senses the room temperature automatically to select a suitable running method for
room comfort.
If TURBO mode is selected , the unit will run at super-high fan speed to cool or heat quickly
so that the ambient temperature approachs the preset value as soon as possible.
ƾ
ƾ
ƾ
About LOCK
Press +and - buttons simultaneously to lock or unlock the keyboard. If the remote controller
is locked, the mark will be displayed on it.In this case, pressing any button, the mark will
flicker three times. If the keyboard is unlocked, the mark will disappear.
Replacement of batteries
About SWING UP and DOWN
About switchover between Fahrenheit and Centigrade
1. To set the guide louvre to a desired position, press Swing Up and Down button ( button)
continuously for more than 2s and hold until desired position is achieved. Releasing the button
now stops the swinging at the desired position.
2. After Swing Up and Down mode is switched on, pressing the button again within 2s,
circulates between the various settings.If button is pressed more than 2s later, the
function is switched off.
Under status of unit off, press MODE and - buttons simultaneously to switch and .
1.Remove the battery cover plate from the rear of the remote controller.
(As shown in the figure)
2.Take out the old batteries.
3.Insert two new AAA1.5V dry batteries, and pay attention to the polarity.
4. Replace the battery cover plate.
Notes:
When changing the batteries, do not use old or different batteries,
otherwise, it may cause malfunction of the wireless remote control.
If the wireless remote controller will not be used for a long time, please
remove batteries to prevent damage from leaking batteries.
The operation should be performed in its receiving range.
It should be kept 1m away from the TV set or stereo sound sets.
If the wireless remote controller does not operate normally, please take
the batteries out and replace them after 30 s. If still not operating properly,
replace the batteries.
Sketch map for
changing batteries
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

Vivax cool ACP-24CH70GEEO User manual

Category
Split-system air conditioners
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI