Xilinx KC705 Si570 User manual

Type
User manual
October 2012
KC705 Si570 Fixed
Frequencies
XTP187
© Copyright 2012 Xilinx, Inc. All Rights Reserved.
XILINX, the Xilinx logo, the Brand Window and other designated brands included herein are trademarks of Xilinx, Inc. All other trademarks are the property of
their respective owners.
NOTICE OF DISCLAIMER: The information disclosed to you hereunder (the “Information”) is provided “AS-IS” with no warranty of any kind, express or implied.
Xilinx does not assume any liability arising from your use of the Information. You are responsible for obtaining any rights you may require for your use of this
Information. Xilinx reserves the right to make changes, at any time, to the Information without notice and at its sole discretion. Xilinx assumes no obligation to
correct any errors contained in the Information or to advise you of any corrections or updates. Xilinx expressly disclaims any liability in connection with technical
support or assistance that may be provided to you in connection with the Information. XILINX MAKES NO OTHER WARRANTIES, WHETHER EXPRESS,
IMPLIED, OR STATUTORY, REGARDING THE INFORMATION, INCLUDING ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, OR NONINFRINGEMENT OF THIRD-PARTY RIGHTS.
Revision History
Date Version Description
10/23/12 4.0 Recompiled for 14.3.
07/25/12 3.0 Recompiled for 14.2. Added AR50886.
05/30/12 2.1 Added FMC Si570.
05/08/12 2.0 Recompiled for 14.1.
03/02/12 1.0 Initial version for 13.4.
KC705 Si570 Fixed Frequency Overview
Xilinx KC705 Board
Software Requirements
Setup for the KC705 Si570 Fixed Frequency
KC705 Si570 Fixed Frequency
Changing an Si570 from 156.25 to 19.440 MHz
Other Fixed Frequencies
KC705 FMC Si570 Fixed Frequency
References
Note: This presentation applies to the KC705
KC705 Si570 Fixed Frequency Overview
Description
The KC705 board has a Silicon Labs Si570 Programmable Oscillator that
defaults to 156.25 MHz. Via a series of bitstreams, the frequency of this device
can be changed. This tutorial shows how to change the output frequency of this
device.
Note: Presentation applies to the KC705
Xilinx KC705 Board
ISE Software Requirement
Xilinx ISE 14.3 software
Note: Presentation applies to the KC705
ChipScope Pro Software Requirement
Xilinx ChipScope Pro 14.3 software
Note: Presentation applies to the KC705
KC705 Setup
Connect a USB Type-A to Mini-B cable to the USB
UART connector on the KC705 board
Connect this cable to your PC
KC705 Setup
Connect a USB Type-A to Micro-B cable to the USB
JTAG (Digilent) connector on the KC705 board
Connect this cable to your PC
Power on the KC705 board for UART Drivers Installation
KC705 Setup
Install USB UART Drivers
CP210x_VCP_Win_XP_S2K3_Vista_7.exe
Note: Presentation applies to the KC705
KC705 Setup
Reboot your PC if necessary
Right-click on My Computer
and select Properties
Select the Hardware tab
Click on Device Manager
Note: Presentation applies to the KC705
KC705 Setup
Expand the Ports
Hardware
Right-click on Silicon Labs
CP210x USB to UART
Bridge and select Properties
Note: Presentation applies to the KC705
KC705 Setup
Under Port Settings tab
Click Advanced
Set the COM Port to an open Com Port setting from COM1 to COM4
Note: Presentation applies to the KC705
KC705 Setup
Board Power must be on before starting Tera Term
Start the Terminal Program
Select your USB Com Port
Set the baud to 9600
Note: Presentation applies to the KC705
Setup for KC705 Si570 Fixed Frequency
Unzip the KC705 Si570 Fixed Frequencies Design Files (14.3 C) to
your C:\ drive
Available through http://www.xilinx.com/kc705
Note: Presentation applies to the KC705
KC705 Si570 Fixed Frequency
Open ChipScope Pro and select JTAG Chain Digilent USB Cable…
(1)
Verify 30 MHz operation and click OK (2)
Note: Presentation applies to the KC705
1
2
KC705 Si570 Fixed Frequency
Click OK (1)
Note: Presentation applies to the KC705
1
KC705 Si570 Fixed Frequency
Right-click DEV:0 MyDevice0 (XC7K325T) and select Configure…
Select frequency_monitor.bit
Note: Presentation applies to the KC705
KC705 Si570 Fixed Frequency
Select File Open Project…
Select <Design Path>\ready_for_download\
kc705_si570_freq_monitor.cpj
Note: Presentation applies to the KC705
KC705 Si570 Fixed Frequency
The VIO Console will now show 200 MHz for the system clock, and
156.25 MHz for the User Clock
Note: Presentation applies to the KC705
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Xilinx KC705 Si570 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI