This manual is also suitable for

SAP1000
Active Probe
User Manual
UM60010-E01A
SAP1000 Active Probe User Manual
2 / 19 WWW.S IGLENT.COM
Contents
CONTENTS ............................................................................................................................................................................ 2
1 INTRODUCTION ................................................................................................................................................... 3
2 GENERAL SAFETY SUMMARY ....................................................................................................................... 4
2.1 SAFETY TERMS AND SYMBOLS ........................................................................................................................... 4
2.2 WORKING ENVIRONMENT................................................................................................................................... 5
2.3 CALIBRATION ...................................................................................................................................................... 6
2.4 CLEANING ........................................................................................................................................................... 6
2.5 ABNORMAL CONDITIONS .................................................................................................................................... 6
3 FIRST STEPS........................................................................................................................................................... 8
3.1 DELIVERY CHECKLIST ........................................................................................................................................ 8
3.2 FUNCTIONAL CHECK........................................................................................................................................... 8
3.3 QUALITY ASSURANCE ........................................................................................................................................ 9
3.4 MAINTENANCE AGREEMENT ............................................................................................................................ 10
4 INTRODUCTION ................................................................................................................................................. 11
5 STANDARD ACCESSORIES ............................................................................................................................. 12
6 PROBE OPERATION .......................................................................................................................................... 16
6.1 CONNECTING THE PROBE TO AN OSCILLOSCOPE .............................................................................................. 16
6.2 CONNECTING THE PROBE TO THE TEST CIRCUIT .............................................................................................. 17
7 CONTACT SIGLENT .......................................................................................................................................... 18
SAP1000 Active Probe User Manual
3 / 19 WWW.S IGLENT.COM
1 Introduction
This user manual includes important safety information related to the SAP1000
active probe and simple tutorials for basic operation of the probe.
SAP1000 Active Probe User Manual
4 / 19 WWW.S IGLENT.COM
2 General Safety Summary
This chapter contains information and warnings that must be followed to keep
the probe operating under the appropriate safety conditions. In addition to the
safety precautions specified in this section, you must also follow recognized
safety procedures.
Connect and disconnect properly. Connect probe to the measurement
instrument before connecting the test leads to a circuit/signal being tested.
Use indoors only.
Keep product surfaces clean and dry.
Use only within operational environment listed. Do not use in wet or
explosive environments.
Be careful with sharp tips. The tips may cause bodily injury if not handled
properly.
Connect the signal wire correctly. The potential of the signal wire
ground is equal to the earth; therefore, do not connect the signal wire to a
high voltage. Do not touch the exposed contacts or components.
Only qualified technical personnel should service this instrument.
Do not operate with suspected failures. Do not use the probe if any part
is damaged. Cease operation immediately and remove the probe from
use.
2.1 Safety Terms and Symbols
This symbol may appear on the probe body or in this manual to alert you to
SAP1000 Active Probe User Manual
5 / 19 WWW.S IGLENT.COM
important safety considerations.
CAUTIONPotential for damage to probe or instrument it is connected
to. Attend to the accompanying information to protect against personal
injury or damage. Do not proceed until conditions are fully understood
and met.
2.2 Working Environment
The accessory is intended for indoor use and should be operated in a clean,
dry environment. Before using this product, ensure that its operating
environment is maintained within these parameters:
Temperature: 5 to 40° C.
Humidity: Maximum relative humidity 80% for temperatures up to 30 °C
decreasing linearly to 50% relative humidity at 40° C.
Altitude: Up to 10,000 ft (3,048 m).
Note: Direct sunlight, radiators, and other heat sources should be taken into
account when assessing the ambient temperature.
WARNING: Do not operate the probe in an explosive atmosphere or wet
and damp conditions.
CAUTION: Do not exceed the specified input maximum voltage levels.
Refer to Specifications for more details.
SAP1000 Active Probe User Manual
6 / 19 WW W.SIGLENT.COM
2.3 Calibration
The recommended calibration interval is one year. Calibration should be only
performed by qualified personnel.
2.4 Cleaning
The exterior of the probe and cable should be cleaned, using a soft cloth
moistened with water. The use of abrasive agents, strong detergents, or other
solvents may damage the probe. Always ensure that the input leads are free of
debris. To avoid electrical shock, unplug the probe from the scope before
cleaning.
No operator serviceable parts inside. Do not remove covers.
Refer servicing to qualified personnel
2.5 Abnormal Conditions
Only operate the probe for the purposes specified by the manufacturer.
Do not operate the probe if there is any visible sign of damage or if it has been
subjected to severe transport stresses.
If you suspect the probe has been impaired, disconnect the probe from the
scope and secure the probe against any unintended operation.
SAP1000 Active Probe User Manual
7 / 19 WW W.SIGLENT.COM
Proper use of the probe depends on careful reading of all instruction and
labels.
Warning: Any use of the probe in a manner not specified by the
manufacturer may impair the probe. This probe should not be directly
connected to human subjects or used for patient monitoring.
SAP1000 Active Probe User Manual
8 / 19 WW W.SIGLENT.COM
3 First steps
3.1 Delivery Checklist
First, verify that all items listed on the packing list have been delivered. If you
note any omissions or damage, please contact your nearest SIGLENT
customer service center or distributor as soon as possible. If you fail to contact
us immediately in case of omission or damage, we will not be responsible for
replacement.
3.2 Functional Check
The functional check verifies the basic functional of the probe functions.
1. Turn the oscilloscope on and allow at least 30 minutes warm-up time
before functional check.
SAP1000 Active Probe User Manual
9 / 19 WW W.SIGLENT.COM
2. Connect the SAP1000 probe to channel 1 of the oscilloscope.
3. Touch Probe in the C1 menu, and then check the information of the probe,
including the probe type, probe SN, bandwidth, resistance, capacitance
and attenuation.
4. Set the vertical scale of channel 1 to 2 V/div.
5. Set the offset of channel 1 to zero.
6. Measure the average voltage of channel 1.The measurement should be
within ± (1.5% * full screen reading + 10 mV).
7. Set the vertical scale of channel 1 to1 V/div, 500 mV/div, 200 mV/div, 100
mV/div, 50 mV/div, 20 mV/div, 10 mV/div, and repeat step 6.
3.3 Quality Assurance
The probe has a 3-year warranty (1-year warranty for probe attachments) from
the date of shipment, during normal use and operation. SIGLENT can repair or
replace any product that is returned to the authorized service center during the
warranty period. We must first examine the product to make sure that the
SAP1000 Active Probe User Manual
10 / 19 WWW.SIGLENT.COM
defect is caused by the process or material, not by abuse, negligence, accident,
abnormal conditions or operation.
SIGLENT shall not be responsible for any defect, damage, or failure caused by
any of the following:
a) Attempted repairs or installations by personnel other than SIGLENT.
b) Connection to incompatible devices/incorrect connection.
c) For any damage or malfunction caused by the use of non-SIGLENT
probe power supplies.
3.4 Maintenance Agreement
SIGLENT provides various services on the basis of maintenance agreements.
We offer extended warranties as well as installation, training, enhancement
and on-site maintenance and other services through specialized
supplementary support agreements. For details, please consult your local
SIGLENT customer service center or distributor.
SAP1000 Active Probe User Manual
11 / 19 WWW.SIGLENT.COM
4 Introduction
The SAP1000 is a compact, high impedance active probe designed to meet
today’s increasing demand for measurements on a variety of tests. Thanks to
its low input capacitance and high input resistance, the circuit loading is
minimized.
With the SAPBus interface, the SAP1000 becomes a part of the oscilloscope
system. The probe can be controlled from the oscilloscope. The oscilloscope
provides power to the probe, so there is no need for a separate power supply
or batteries.
Key Benefits:
Probe Bandwidth > 1 GHz
DC Input Resistance 1 MΩ
Input Capacitance 1.2 pF
Input Dynamic Range ±8 V
Probe Offset Range ±12 V
SAPBus interface
SAP1000 Active Probe User Manual
12 / 19 WWW.SIGLENT.COM
5 Standard Accessories
The SAP1000 probe is shipped with the following standard accessories:
Standard Accessory
Quantity
Straight Tip
5
Pogo Tip
5
L-adapter
1
Z-Ground
1
Y-Lead Adapter
1
50 Right Angle Pin Lead
1
60 Straight Pin Lead
1
100 Right Angle Pin Lead
1
120 Straight Pin Lead
1
Colored Clip
8
SAP1000 Active Probe User Manual
13 / 19 WWW.SIGLENT.COM
Straight TipThe straight tip is rugged and designed for general probing.
Pogo TipThe pogo tip provides z axis compliance. The tip can fit into a socket
or via and onto an IC leg.
SAP1000 Active Probe User Manual
14 / 19 WWW.SIGLENT.COM
L-adapterThis adapter has a socket on one end and a square pin with a right
angle on the other to connect to the input or ground socket of the probe body,
and may be used for high frequency applications.
Z-GroundThe Z-Ground is designed to be attached to either socket of the
probe head. The Z-Ground is the highest quality grounding solution and is
recommended in high frequency applications.
Y-Lead Adapter This lead is used for both ground and input lead
simultaneously. It has two sockets on one end and two round pins on the other
and may be used for general purpose probing.
60/120 Straight Pin LeadThese leads have a socket on one end and a round
pin on the other to connect to the input or ground socket of the probe body,
and may be used for general purpose probing.
SAP1000 Active Probe User Manual
15 / 19 WWW.SIGLENT.COM
50/100 Right Angle Pin Lead :These leads have a socket on one end and a
round pin with a right angle on the other to connect to the input or ground
socket of the probe body, and may be used for general purpose probing.
Colored Clips: These colored clips can be used to distinguish a specific probe
from other similar probes being used in the measurement.
SAP1000 Active Probe User Manual
16 / 19 WWW.SIGLENT.COM
6 Probe Operation
The SAP1000 probe is a precision test instrument. Exercise care when
handling and storing the probe. Always handle the probe by the probe body or
compensation box. Avoid putting excessive strain or exposing the probe cable
to sharp bends.
ESD Sensitive: The tips of the probes are sensitive to Electrostatic
Discharge (ESD). Avoid causing damage to the probe by always
following anti-static procedures when using or handling the probe.
6.1 Connecting the Probe to an Oscilloscope
The SAP1000 probe has been designed for being used with SIGLENT’s
SDS5000X oscilloscope equipped with the SAPBus interface. When you
attach the probe output connector to the oscilloscope’s input connector, the
oscilloscope detects the probe automatically.
When the SAP1000 probe is connected to any compatible SIGLENT
oscilloscope, the displayed scale factor and measurement values are
automatically adjusted. The probe can be controlled through the oscilloscope
graphical user interface. Turning the Volts/div knob controls the oscilloscope’s
scale factor to give full available dynamic range up to 2 V/div (16 V peak to
peak). Turning the channel offset knob controls the probe input offset circuit
over its range of ±12 V.
SAP1000 Active Probe User Manual
17 / 19 WWW.SIGLENT.COM
6.2 Connecting the Probe to the Test Circuit
To maintain the high-performance capability of the probe in measurement
applications, care must be exercised in connecting the probe to the test circuit.
Increasing the parasitic capacitance or inductance in the input paths may
introduce a “ring” or slow the rise time of fast signals. Input leads which form a
large loop area will pick up any radiated electromagnetic field which passes
through the loop and may induce noise into the probe input.
SAP1000 Active Probe User Manual
18 / 19 WWW.SIGLENT.COM
7 Contact SIGLENT
America
SIGLENT Technologies NA, Inc
6557 Cochran Rd Solon, Ohio 44139
Tel: 440-398-5800
Toll Free:877-515-5551
Fax: 440-399-1211
info@siglent.com
www.siglentamerica.com
Headquarters
SIGLENT TECHNOLOGIES CO., LTD.
Blog No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an District,
Shenzhen, 518101, China.
Tel:+ 86 755 3688 7876
Fax:+ 86 755 3359 1582
market@siglent.com
www.siglent.com/ens
Europe
SIGLENT TECHNOLOGIES EUROPE GmbH
Liebigstrasse 2-20, Gebaeude 14, 22113 Hamburg Germany
Tel: +49(0)40-819-95946
Fax: +49(0)40-819-95947
info-eu@siglent.com
www.siglenteu.com
SAP1000 Active Probe User Manual
19 / 19 WWW.SIGLENT.COM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

SIGLENT SAP1000 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI