Miller LJ40081C Owner's manual

Category
Welding System
Type
Owner's manual

This manual is also suitable for

Processes
Description
OM-241 101B 200903
Junction Box For Welding System
Junction Box
File: MIG (GMAW)
Visit our website at
www.MillerWelds.com
Includes System Connection Information
Multiprocess Welding
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual specification sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owners Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
parts list will then help you to decide the
exact part you may need to fix the problem.
Warranty and service information for your
particular model are also provided.
Miller is the first welding
equipment manufacturer in
the U.S.A. to be registered to
the ISO 9001:2000 Quality
System Standard.
Working as hard as you do
every power source from
Miller is backed by the most
hassle-free warranty in the
business.
From Miller to You
Mil_Thank 4/05
TABLE OF CONTENTS
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 CONSIGNES DE SÉCURITÉ LIRE AVANT UTILISATION 5. . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Symboles utilisés 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers relatifs au soudage à l’arc 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance 7. . . . . .
2-4. Proposition californienne 65 Avertissements 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Principales normes de sécurité 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Information EMF 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 DEFINITIONS 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Symbols And Definitions 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 SPECIFICATIONS 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Welding System Description 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Junction Box Description 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Welding System Specifications 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Junction Box Specifications 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 INSTALLATION 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Typical Equipment Location Wire Feeder Mounted On Boom 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Typical Equipment Location Wire Feeder Mounted On Post 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Mounting Junction Box 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-4. Junction Box Components 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5. Connecting Weld Cables To Junction Box 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-6. Connecting Remote Control Cables 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-7. Remote 16 Receptacle RC3 Information 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-8. Remote 14 Receptacle RC4 Information 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-9. Connecting AC Power Cable 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-10. Connecting Compressed Air To Junction Box 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-11. Connecting Welding Gas To Junction Box 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 OPERATION 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Junction Box Components 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 MAINTENANCE AND TROUBLESHOOTING 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-1. Routine Maintenance 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 ELECTRICAL DIAGRAM 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 PARTS LIST 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-241 101 Page 1
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING
som _200704
7
Protect yourself and others from injury — read and follow these precautions.
1-1. Symbol Usage
DANGER! Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or ex-
plained in the text.
NOTICE Indicates statements not related to personal injury.
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult sym-
bols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the follow-
ing electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoid-
able or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit volt-
age. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Always verify the supply ground check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conduc-
tor first double-check connections.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord for damage or bare wiring
replace cord immediately if damaged bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not drape cables over your body.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding ma-
chines at the same time since double open-circuit voltage will be
present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists in inverter-type
welding power sources after removal of input
power.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can cause severe burns.
D Do not touch hot parts bare handed.
D Allow cooling period before working on gun or
torch.
D To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and
clothing to prevent burns.
OM-241 101 Page 2
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
FUMES AND GASES can be hazardous.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases.
D If ventilation is poor, wear an approved air-supplied respirator.
D Read and understand the Material Safety Data Sheets (MSDSs)
and the manufacturer’s instructions for metals, consumables,
coatings, cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
ARC RAYS can burn eyes and skin.
D Wear an approved welding helmet fitted with a proper shade of fil-
ter lenses to protect your face and eyes when welding or watching
(see ANSI Z49.1 and Z87.1 listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant mate-
rial (leather, heavy cotton, or wool) and foot protection.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
WELDING can cause fire or explosion.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material.
D Protect yourself and others from flying sparks and hot metal.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Do not weld where the atmosphere may contain flammable dust,
gas, or liquid vapors (such as gasoline).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
D Use only correct fuses or circuit breakers. Do not oversize or by-
pass them.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
FLYING METAL or DIRT can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut off shielding gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
MAGNETIC FIELDS can affect Implanted
Medical Devices.
D Wearers of Pacemakers and other Implanted
Medical Devices should keep away.
D Implanted Medical Device wearers should consult their doctor
and the device manufacturer before going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
CYLINDERS can explode if damaged.
D Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder explosion will result.
D Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and
associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient num-
ber of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
OM-241 101 Page 3
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING UNIT can cause injury.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
OVERUSE can cause OVERHEATING
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
FLYING SPARKS can cause injury.
D Wear a face shield to protect eyes and face.
D Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
D Sparks can cause fires — keep flammables away.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
MOVING PARTS can cause injury.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
WELDING WIRE can cause injury.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
MOVING PARTS can cause injury.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
D Read Owner’s Manual before using or servic-
ing unit.
D Use only genuine replacement parts from the
manufacturer.
H.F. RADIATION can cause interference.
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
D The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
D If notified by the FCC about interference, stop using the
equipment at once.
D Have the installation regularly checked and maintained.
D Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
ARC WELDING can cause interference.
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
D To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
D Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
D Be sure this welding machine is installed and grounded
according to this manual.
D If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
OM-241 101 Page 4
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
Battery posts, terminals and related accessories contain lead
and lead compounds, chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
For Gasoline Engines:
Engine exhaust contains chemicals known to the State of
California to cause cancer, birth defects, or other reproduc-
tive harm.
For Diesel Engines:
Diesel engine exhaust and some of its constituents are
known to the State of California to cause cancer, birth
defects, and other reproductive harm.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers and Piping, American Welding Society Standard
AWS F4.1, from Global Engineering Documents (phone:
1-877-413-5184, website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, P.O. Box 9101, Quincy, MA 02269-9101 (phone:
617-770-3000, website: www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 4221 Walney Road, 5th Floor,
Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 5060 Mississauga,
Ontario, Canada L4W 5NS (phone: 800-463-6727 or in Toronto
416-747-4044, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protec-
tion, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036–8002 (phone:
212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
P.O. Box 9101, Quincy, MA 02269-9101 (phone: 617-770-3000, web-
site: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Indus-
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Super-
intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 Regional Offices—phone for
Region 5, Chicago, is 312-353-2220, website: www.osha.gov).
1-6. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
Welding current, as it flows through welding cables, will cause electro-
magnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to power-
frequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
To reduce magnetic fields in the workplace, use the following
procedures:
1. Keep cables close together by twisting or taping them, or using a
cable cover.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from opera-
tor as practical.
5. Connect work clamp to workpiece as close to the weld as possi-
ble.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recom-
mended.
OM-241 101 Page 9
2-5. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
de Global Engineering Documents (téléphone : 1-877-413-5184, site
Internet : www.global.ihs.com).
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers and Piping, American Welding Society Standard
AWS F4.1 de Global Engineering Documents (téléphone :
1-877-413-5184, site Internet : www.global.ihs.com).
National Electrical Code, NFPA Standard 70, de National Fire Protec-
tion Association, P.O. Box 9101, Quincy, MA 02269-9101 (téléphone :
617-770-3000, site Internet : www.nfpa.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de Compressed Gas Association, 4221 Walney Road, 5th Floor, Chan-
tilly, VA 20151 (téléphone : 703-788-2700, site Internet :
www.cganet.com).
Code for Safety in Welding and Cutting, CSA Standard W117.2, de
Canadian Standards Association, 5060 Mississauga, Ontario, Canada
L4W 5NS (téléphone : 800-463-6727 ou à Toronto 416-747-4044, site
Internet : www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protec-
tion, ANSI Standard Z87.1, de American National Standards Institute,
11 West 43rd Street, New York, NY 10036-8002 (téléphone :
212-642-4900, site Internet : www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, de National Fire Protection Association,
P.O. Box 9101, Quincy, MA 02269-9101 (téléphone : 617-770-3000,
site Internet : www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General Indus-
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, de U.S. Government Printing Office, Superin-
tendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(téléphone : 1-866-512-1800) (il y a 10 bureaux régionaux−−le télépho-
ne de la région 5, Chicago, est 312-353-2220, site Internet :
www.osha.gov).
2-6. Information EMF
Considérations sur le soudage et les effets de basse fréquence et des
champs magnétiques et électriques.
Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir exa-
miné plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National
Research Council a conclu : « L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine ». Toutefois, des études sont toujours en
cours et les preuves continuent à être examinées. En attendant que les
conclusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.
Pour réduire les champs magnétiques sur le poste de travail, appliquer
les procédures suivantes :
1. Garder les câbles ensemble, les torsader, les scotcher, ou les
recouvrir d’une housse.
2. Disposer les câbles d’un côté et à distance de l’opérateur.
3. Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
4. Garder le poste de soudage et les câbles le plus loin possible de
vous.
5. Connecter la pince sur la pièce aussi près que possible de la
soudure.
En ce qui concerne les implants médicaux :
Les porteurs d’implants doivent d’abord consulter leur médecin avant
de s’approcher des opérations de soudage à l’arc, de soudage par
points, de gougeage, du coupage plasma ou de chauffage par induc-
tion. Si le médecin approuve, il est recommandé de suivre les
procédures précédentes.
OM-241 101 Page 11
SECTION 3 DEFINITIONS
3-1. Symbols And Definitions
A
Amperes
V
Volts Output
Hz
Hertz
Circuit Breaker High Temperature Positive Negative
Alternating Current
(AC)
Input Remote
SECTION 4 SPECIFICATIONS
. Also see the power source, wire feeder, and boom Owner’s Manuals for additional information.
4-1. Welding System Description
The HM welding system provides Constant Voltage (CV) and Constant Current (CC) weld output for multiprocess
welding. Each weld station (cell) includes a welding power source (CV or CC/CV), wire feeder, floor-mounted
boom or pedestal supports, a junction box, and the dedicated weld cables, gas hoses, air hoses, 115 volt AC
power cable, and remote control cables. The power sources for each weld station, typically installed in the plant
mezzanine adjacent to the welding operation, supply weld current to the junction box. Secondary weld cables,
control cables, and gas hoses from the junction box are connected to the boom or pedestal-mounted wire feeder.
Depending on the weld output desired, the user has the option of connecting to either power source. The wire
feeder can be mounted on the overhead boom or easily moved to the pedestal. For increased mobility, an option-
al bracket allows the wire feeder to be installed on a cart-mounted power source. See Section 5 for typical
installations.
4-2. Junction Box Description
The junction box is the connection
point for components of the welding
system. The box provides input and
output connections for weld cables,
welding gas, compressed air, and
remote control cables. An AC re-
ceptacle in the junction box sup-
plies 115 volt AC power for operat-
ing tools. The junction box com-
pressed air connection can be used
for Carbon Arc Cutting and Gou-
ging (CAC-A) or for operating pneu-
matic equipment.
. Weld output stops when the
junction box door is opened.
Power is still available at the
115 volt AC receptacle.
805 398
OM-241 101 Page 12
4-3. Welding System Specifications
Specification Description
System Components Constant Current/Constant Voltage (CC/CV) Welding Power Source, Constant Voltage (CV) Power
Source, Constant Voltage Wire Feeder, Boom, Pedestal, Junction Box, Weld Cables, Air Hoses And
Fittings
Welding Processes MIG (GMAW) Welding, Pulsed MIG (GMAW-P) Welding, Stick (SMAW) Welding, Air Carbon Arc
(CAC-A) Cutting and Gouging
Welding Circuit Rating 100 Volts, 400 Amperes, 100% Duty Cycle
4-4. Junction Box Specifications
Specification Description
Input Power
(For AC Receptacle And Wire Feeder)
115 Volts AC, 20 Amperes, Single-Phase, 50/60 Hz
Output Power For Wire Feeder 24 Volts AC, 8 Amperes, Single-Phase, 50/60 Hz
Output Power For AC Receptacle 115 Volts AC, 20 Amperes
Overall Dimensions 20 x 9 x 14 in. (508 x 229 x 356 mm)
Weight 34 lb (15.4 kg)
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-241 101 Page 13
SECTION 5 INSTALLATION
. Customer must supply welding gas and compressed air.
. See Section 8 for junction box and welding system electrical diagrams.
5-1. Typical Equipment Location Wire Feeder Mounted On Boom
805 399-B
1 Welding Power Source
2 Boom
3 Wire Feeder
4 Junction Box
5 115 Volt AC Cable
6 Weld Cables
7 Remote Control Cable
(Remote 14)
8 Welding Gas Hose
9 Compressed Air Hose
10 MIG Gun (Not Shown)
1
5
4
7
2
3
8
9
6
5-2. Typical Equipment Location Wire Feeder Mounted On Post
805 399-B
1 Welding Power Source
2 Post
3 Wire Feeder
4 Junction Box
5 115 Volt AC Cable
6 Weld Cables
7 Remote Control Cable
(Remote 14)
8 Welding Gas Hose
9 Compressed Air Hose
10 MIG Gun (Not Shown)
1
5
4
7
2
3
8
9
6
OM-241 101 Page 14
5-3. Mounting Junction Box
1 Junction Box
2 Boom
3 3/8 16 x 1-1/2 in. Screw
To mount junction box, install 3/8 in.
hardware in pre-drilled holes in
boom, or post bracket.
Tools Needed:
805 400
1
2
3
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-241 101 Page 15
5
-4. Junction Box Components
. Weld output and 115 volt AC out-
put (at the junction box) stops
when the remote control cable is
disconnected anywhere in the
system.
. Weld output stops when the junc-
tion box door is opened. Power is
still available at the 115 volt AC
receptacle.
1 Circuit Breaker CB1
2 Weld Gas Inlet Connection
3 Weld Gas Outlet Connection
4 Weld Gas Control Switch
Use switch to turn weld gas on and off.
5 Safety Interlock Switch
Switch stops weld output when door
is open. Power is still available at the
115 volt AC receptacle.
6 AC Receptacle LED
LED lights when 115 volts AC is avail-
able at the receptacle.
7 115 Volt, 20 A 60 Hz AC
Receptacle
8 High Temperature Shutdown
LED
9 Positive (+) Weld Cable Input
Receptacle
10 Negative () Weld Cable Input
Receptacle
11 Positive (+) Weld Cable Output
Receptacle
12 Negative () Weld Cable Output
Receptacle
13 Remote 16 Input Receptacle
RC3
14 Remote 14 Output Receptacle
RC4
15 Compressed Air Input
Connection
16 Compressed Air Output
Connection
17 115 Volt, 20 A AC Input
Connection (Twistlock)
805 401
Front
2
3
4
5
6
7
8
1
11 12
91013
1415 16
17
Bottom View
OM-241 101 Page 16
5-5. Connecting Weld Cables To Junction Box
! Turn Off welding power
source(s) and disconnect
input power before making
connections.
. See power source and wire
feeder Owners Manuals for
additional information.
. Weld output and 115 volt AC
output (at the junction box)
stops when the remote con-
trol cable is disconnected
anywhere in the system.
. Weld output stops when junc-
tion box door is opened.
Power is still available at the
115 volt AC receptacle.
Open access door.
Route cables through opening in
bottom of box prior to making con-
nections.
1 Positive (+) Weld Cable
Input And Output
Receptacles
2 Negative () Weld Cable
Input And Output
Receptacles
Connect weld input cables (from
power source) to Positive and
Negative input receptacles first.
. The weld input cables (from
power source) have camlock
connectors and are installed
in the back receptacles.
The weld output cables (to
feeder) have Dinse connect-
ors and are installed in the
front receptacles.
Connect weld output cables (to
wire feeder) to Positive and Neg-
ative output receptacles.
Tools Needed:
1
2
805 402
OM-241 101 Page 17
! Turn Off welding power
source(s) and disconnect in-
put power before making
connections.
. See power source and wire
feeder Owner’s Manuals for
additional information.
. See Section 5-8 for Remote 14
receptacle information.
Route cables through opening in
bottom of box prior to making con-
nections.
1 Remote 16 Input Receptacle
(Back)
2 Remote 14 Output Receptacle
(Front)
Connect remote 16 input cable
(from power source) to input re-
ceptacle first. Connect remote 14
output cable (to feeder) to output re-
ceptacle.
To connect cable to receptacle,
align keyway, insert plug, and
tighten threaded collar.
5-6. Connecting Remote Control Cables
Tools Needed:
805 403
12
OM-241 101 Page 18
5-7. Remote 16 Receptacle RC3 Information
. Remote receptacle RC3 is
behind remote receptacle RC4.
REMOTE 16
Socket* Socket Information
24 VOLTS AC
1 24 volts AC. Protected by supplementary protector
CB2.
2 Contact closure to A completes 24 volts AC contac-
tor control circuit.
REMOTE
OUTPUT
CONTROL
3 +10 volts DC (referenced to pin 4) for remote com-
mand control.
4 Remote control circuit common.
5 0 to +10 volts DC input command signal (refer-
enced to pin 4) from remote control.
8 To remote On/Off circuit. Connect to chassis com-
mon to energize power source.
11 CC/CV select. Defaults to CV. Connect to pin 4 for
CC.
A/V
AMPERAGE
VOLTAGE
6 Current feedback; +1 volt DC per 100 amperes ref-
erenced to pin 4.
7 Voltage feedback; +1 volt DC per 10 arc volts refer-
enced to pin 4.
10 Wirefeed speed feedback; +1 volt DC per 100 IPM
(inches per minute) referenced to pin 4.
Remote Voltage
Sensing
9 Voltage sensing input from Negative () sense
point.
12 Voltage sensing input from Positive (+) sense point.
13 For future use.
*The remaining sockets are not used.
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-241 101 Page 19
5-8. Remote 14 Receptacle RC4 Information
AJ
B
K
I
C
L
NH
D
M
G
E
F
. Remote receptacle RC4 is in
front of remote receptacle RC3.
Socket Socket Information
24 VOLTS AC
A 24 volts AC. Protected by supplementary protector
CB2.
B Contact closure to A completes 24 volts AC contac-
tor control circuit.
REMOTE
OUTPUT
CONTROL
C +10 volts DC (referenced to pin D) for remote com-
mand control.
D Remote control circuit common.
E 0 to +10 volts DC input command signal (refer-
enced to pin D) from remote control.
I To remote On/Off circuit. Connect to pin K to ener-
gize power source.
M CC/CV select. Defaults to CV. Connect to pin D for
CC.
A/V
AMPERAGE
VOLTAGE
F Current feedback; +1 volt DC per 100 amperes ref-
erenced to pin D.
H Voltage feedback; +1 volt DC per 10 arc volts refer-
enced to pin D.
L Wirefeed speed feedback; +1 volt DC per 100 IPM
(inches per minute) referenced to pin D.
GND
G Circuit common for 24 volt AC circuits.
J Ground current sense output to wire feeder.
K Chassis common.
Remote Voltage
Sensing
N Voltage sensing signal from Positive (+) sense
point.
Notes
BUTT
BUTT
BUTT
BUTT
TJOINT
TJOINT
TJOINT
TJOINT
FILLET
GROOVE
FLAT VERTICALHORIZONTAL OVERHEADWELD POSITION:
WELD JOINT
TYPES
Ref. AWS/ANSI D1.1
1G
1F
2G
2F
3G
3F
4G
4F
Ref. 804 248-A
OM-241 101 Page 20
5-9. Connecting AC Power Cable
! Turn Off welding power
source(s) and disconnect
input power before mak-
ing connections.
. See power source and wire
feeder Owner’s Manuals
for additional information.
Route cable through opening in
bottom of box prior to making
connection.
1 115 Volt, 20 A AC Input
Connection (Twistlock)
Connect 115 volt AC input
power cable (from power
source) to twistlock receptacle.
Tools Needed:
805 404
1
OM-241 101 Page 21
5-10. Connecting Compressed Air To Junction Box
Tools Needed:
! Turn Off welding power
source(s) and disconnect
input power before mak-
ing connections.
! Do not use compressed
air for breathing. Use
only for cutting, gouging,
and tools.
! Do not direct air stream
toward others.
. See power source and wire
feeder Owner’s Manuals
for additional information.
Route air hoses through open-
ing in bottom of box prior to mak-
ing connections.
1 Compressed Air Input
Connection
2 Compressed Air Output
Connection
Connect compressed air input
hose (from supply) to air input
connection first.
Connect compressed air output
hose (to pneumatic equipment)
to air output connection.
805 405
12
OM-241 101 Page 22
5-11. Connecting Welding Gas To Junction Box
! Turn Off welding power
source(s) and disconnect
input power before mak-
ing connections.
. See power source and wire
feeder Owner’s Manuals
for additional connection in-
formation.
Route hoses through opening in
bottom of box prior to making
connections.
1 Weld Gas Inlet Connection
(5/8-18 UNF)
2 Weld Gas Outlet
Connection (5/8-18 UNF)
Connect welding gas input hose
(from supply) to inlet connection
first.
Connect welding gas output
hose (to feeder) to outlet con-
nection.
Tools Needed:
805 406
1
2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Miller LJ40081C Owner's manual

Category
Welding System
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages