Signal-Tech LSi Series Outdoor LED Backlit Monument Sign User manual

Category
Motorcycle Accessories
Type
User manual
Power & Communications
1. Turn off incoming power prior to
starting installation.
2. All terminations should be made using
the provided 5-conductor lever-nuts.
(No additional wire nuts required.)
3. A single Hot input is provided for
the backlighting
4. Brown Wires: Hot/ACL
5. Blue Wires: Neutral/ACN
(may be combined with white wire
from variable message inserts)
6. Green/Yellow Wires: Earth Ground
(sign cabinet and power supply
grounds combined)
Backlit Panel Wiring Connections
Last Revised 22 Mar 2021
Open Port
Lever
Wire stripped 11mm or about 7/16"
Hot
(Backlight)
Neutral
Earth Ground
Power Supplies
1. Strip the ends of your input wire to 11mm, using the
guide on the side of one of the lever-nuts.
2. To make a connection, use the wiring scheme
pictured to find the correct lever-nut.
a. Pull up on lever of an open port
b. Insert conductor
c. Push lever back down
Lever-nut Instructions
What You Need:
Phillips Head Screw Driver
Control Switch (ordered separately)
Voltage
This sign operates within an input range of 120VAC to 277VAC.
LSi SERIES
Outdoor LED Backlit Monument Sign
Installation Instructions
Always turn o
the power prior
to installation.
Be sure any metal
debris cleared
out of the cabinet.
Variable Message Displays
LED Backlit Face
Reverse side of the face showing
1. With the sign mounted, open sign cabinet by
removing the 2 (two) screws located on the bottom
of the front panel.
3. Reattach the cabinet to the brackets
with the hardware provided.
2. With the front hinged panel supported open
locate the variable message displays.
Each display will have its own wiring.
Variable Message Displays
LED Backlit Face
Variable Message Insert Wiring Connections
1. Each variable message insert will have a stripped-end wire
for each message. Be sure to reference the Wiring Label
on the back of each display panel.
(See General Wiring Guidelines below)
Note: Make appropriate wiring connections
per local code.
WARNING: Risk of Fire or Electric Shock. Do Not
interconnect output terminations.
AVERTISSEMENT: Risque d’incendie ou de choc électrique.
Ne pas interconnecter les terminaisons
de sortie.
Note: This unit contains a built-in CLASS 2
LED driver.
Note: Any holes drilled into sign cabinet MUST
be sealed. Failure to do so may cause a
short and void warranty.
Note: This sign is intended to be installed in
accordance with the requirements of
Article 600 of the National Electric Code
and/or other applicable local codes. This
includes proper grounding and bonding
of the sign.
Warning Statements
Hot
Neutral
Earth Ground
Power Supplies
Power Supply
Pigtail Connector
Pigtail Connector
removed
*Neutral is solid White
and Ground (if equipped)
is solid Green.
Typical Wire (Lead) Colors
Black with White Stripes
Black with Yellow Stripes
Black with Red Stripes
Black with Blue Stripes
Black with Gray Stripes
Black with Orange Stripes
Black with Purple Stripes
Black with Green Stripes
Black with Brown Stripes
4.
5.
6.
3. To make your electrical connections easier, gently unplug
the supplied wired pigtail connector from the power supply.
With your incoming power already running through the
mounted back you can easily make all connections to the
pigtail using wire connectors.
(See table below for General Wiring Guidelines)
Plug the pigtail connector back into the power supply to
finish off the electrical part of your installation. The connector
is “keyed” and can only be installed in one orientation
You’re done with the electrical! Time to close up the sign by
pushing the cabinet closed and replacing the two screws you
removed from the bottom of the cabinet.
(Some wires may
not be used)
Two Message Sign #1 Two Message Sign #2
Message 2
Black/Blue
Pigtail located
on sign back
Pigtail located
on sign back
Message 1
Black/Red
Message 2
Black/Yellow
Message 1
Black/White
General Wiring Guidelines*
Sample Wiring Label
Note: Refer to the wiring label inside the sign for the specific
instructions on wiring your sign. Some wires may not be used.
Wiring Label Sample for a typical 2 Message OPEN | CLOSED Sign
Note: Make appropriate wiring connections per local code.
SAMPLE
120 VAC
60Hz - 1PH
NOTES:
LINE
NEUTRAL
SIGN
1. SWITCH TYPE MAY
2. SIGN LEAD COLOR
CHART IS SHOWN
BELOW
3. INDICATOR LIGHTS
ARE OPTIONAL AND
WIRED IN PARALLEL
TO SIGN MESSAGES
VARY THIS IS ONLY A
TYPICAL
Product ID: 5887
Message
OPEN
CLOSED
COMMON
GROUND (IF EQUIPPED)
Wire Color
Black with White Stripes
Black with Red Stripes
White
Green
Sign connections are rated for 120-277 VAC
Wire colors not listed here are unused.
2. A common neutral is pre-wired; terminate neutral using the
lever-nut referenced in the Backlit panel Wiring Instructions.
  • Page 1 1
  • Page 2 2