LS1000R

Honeywell LS1000R User manual

  • Hello! I've analyzed the installation and operating instructions for the Honeywell LightSpot LS1000R motion sensor. This document covers the installation, operation, and technical details of the product. It explains features such as manual override, adjustable time and dusk level functions and different mounting options. I am ready to help with any questions you might have about this device.
  • What is the maximum switchable load for incandescent or halogen lamps?
    What is the warm-up time for the device?
    What is the detection range of the sensor?
    What is the time on adjustment range?
PACK CONTENTS
REQUIRED (Warning: Use only VDE Certified Tools)
MOUNTING/ INSTALLATION STEPS
Surface Mount
1
4
2
5
3
6
7
9
0FF
φ
5mm
50.8mm or 60mm
60mm
50.8mm
CAUTION:
OR
OR
‘CLICK’ ‘CLICK’
‘CLICK’
The device needs
20-50 seconds to
warm up.
1 x 2.5m
Cable entry
capability at
terminal block
2 x 1.0m
2 x 1.5m
Cut out
here
x1x1 x1 x1
M4 x 14mm
x2
(For Euro conduit box
installation)
M3 x 20mm
(For ceiling mout
installation)
M3 x 15mm
(For cable clamps
installation)
x2 x4 x2 x2
x1 x1 x1 x1 x1
Hole saw size:
x1
Ф75mm - 80mm
Ф5mm
4mm
No 2
Phillips
3mm
LS htSpot 360100 Lig0R ° Dual Mount PIR installation and operating instructions
Only suitably qualified personnel should install this equipment
!!
8
Remark: R terminals are Volt-Free output
(when link is removed)
Option1 (live out) Option2 (volt-free)
LLive
N
Brown
RSwitched Live Brown
Neutral Blue
Earth Green / Yellow
LLive
N
Brown
RVolt-Free
RRelay contact Brown
Neutral Blue
Earth Green / Yellow
N
N L
µ
R R
L
N
N L R R
L
R
R
µ
•To prevent electrocution, do not work on any appliance live. Turn off mains before commencing work, lock-out tag-out must be followed.
•The current editions of the IEE Wiring Regulations (BS7671) and Buildings Regulations must be followed for installation.
•Ensure all terminal screws are fully tightened and product is securely fixed to its mounting box prior to turning on the mains supply.
Load
Note: Remove the external link
RRLN
WALK TESTING
1 3
MANUAL OVERRIDE OPERATION
Activate Manual Override Operation
SWITCHABLE LOAD
TECHNICAL SPECIFICATIONS
Detection Range:
Detection Angle:
Power Supply:
Maximum Switchable Load:
Time On Adjustment:
Dusk Level Adjustment:
Operating temperature:
Environment Protection:
Up to 6 metres diameter (3m Radius)
at mounting height of 2.5m
36
230Vac 50Hz
Max load current 10A
Incandescent / Halogen Max 2000W
Fluorescent lamp (magnetic) Max 500W
Fluorescent lamp (electronic ballast) Max 400W
Low energy (CFL) Max 120W
LED lamp Max W400
Fan Max 75W
5 seconds - 15 minutes
Day & night or night only operation
0 to 40 degrees
For ceiling mount - IP44
For flush mount - IP44 (at sensor portion only)
- IP20 (ceiling board onwards)
Max 400W
Max 500W
Max 2000W @230V Max 120W
Max 400W
Max 75W
2
MIN. SUN.
warm up
20-50 SEC
Around
10 second
Lamp turn on
when reach Lux
setting level.
ON
OFF
ON
2 times within 2 seconds
DUSK
DAWN
Hrs
2 SEC
5
SEC
1
Deactivate Manual Override Operation
Manual deactivation before dawn
2Auto deactivation when
dusk to dawn
ON
Lamp turn off when
dusk to dawn.
OFF
ON
1 time within 1 second
1 SEC
5
SEC
OR
Auto Mode
Auto Mode
ON
At the end of their useful life the
packaging and product should
be disposed of via a suitable
recycling centre.
Do not dispose of with normal
GUARANTEE
The company undertake to replace or repair, at its discretion should it become defective within a period
household waste. Do not burn.
of 1 year after delivery, solely as a result of faulty materials and/or workmanship. Understandably, if
the product has not been installed, maintained or used appropriately, or if an attempt has been made to
rectify, dismantle or alter the product in any way, the guarantee will be invalidated.This guarantee states
the company's entire liability. It does not extend to cover consequential loss or damage or installation
cost arising from the defective product.This guarantee does not restrict or infringe the normal statuary
rights of the customer.
COMPLIANCE WITH E.U. DIRECTIVES
Apart from meeting the appropriate British standards, products are
manufactured in accordance with BS EN ISO 9002 and comply
with the LV (72/23/EEC) Directive.
C
M
Y
CM
MY
CY
CMY
K
EU contact for regulatory questions:
PEHA Elektro GmbH & Co.
KG Gartenstraße 49,
58511 Lüdenscheid Germany
Web: www.peha.de
Honeywell
St Marks Court, North Street
Horsham, West Sussex RH12 1BW
Tel: +44 (0)1942 719229
Web:www.buildings.honeywell.com/gb/e
n/brands/our-brands/ex-or
W6039 REVD 12/2/2023
MOUNTING/ INSTALLATION STEPS
Flush Mount
REMOVING
Surface Mount
REMOVING
Flush Mount
‘CLICK’
6 7 8
4 Opening hole
75mm~80mm diameter
Ceiling board
thickness
5mm-20mm
Power wire
9
‘CLICK’
Ceiling board The device need
20-50 seconds to
warm up.
5
1 2 3
0FF
230V
1 x 2.5m
Cable entry
capability at
terminal block
2 x 1.0m
2 x 1.5m
Remark: R terminals are Volt-Free output
(when link is removed)
Option1 (live out) Option2 (volt-free)
LLive
N
Brown
RSwitched Live Brown
Neutral Blue
Earth Green / Yellow
LLive
N
Brown
RVolt-Free
RRelay contact Brown
Neutral Blue
Earth Green / Yellow
N
N L
µ
R R
L
N
N L R R
L
R
R
µ
Load
Note: Remove the external link
RRLN
TOP VIEW
MOTION SENSOR DETECTION
When mounting
at 2.5m height
Dia. 6 METRE
SIDE VIEW
2.5 M
1 M
3 METRE 3 METRE
10
20
30
40
°C
40
LENS MASK
Lens mask
sticker
Restrict
short
detection
Restrict
long
detection
Restrict
detection
directly
under
sensor
Adjustment
30 MIN
SEC
-Can be adjusted by flat head screwdriver.
5 SEC
ON-TIME LUX
TESTING & OPERATION
10
20
30
40
°C
40
10
20
30
40
°C
40
C
M
Y
CM
MY
CY
CMY
K
3 METRE
3 METRE 3 METRE
3 METRE
3 METRE
3 METRE
3 METRE
3 METRE
/