  • Hello! I am an AI chatbot trained to assist you with the Omega RD200 and RD2800 Series Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Basic Manual for
RD200
,
RD2800 Series Recorder
1 Back Terminal connection
Power Su
pp
l
y
2. Sensor Connection
Thermocou
p
le
DC Volta
g
e and Current**
***4/20mA connect 250ohm
resister to the terminal.
RTD
(
PT100ohm
)
***Make sure all terminals are ti
g
htl
y
connected.
3. Date
,
time
,
Year
(
Clock Settin
g)
(
See manual under Time settin
g)
3A. Push SHIFT + CLOC
K
ke
at same time
You will see Dis
p
la
y
-Ori
g
inal set at factor
y
time
)
C
.1.998 01.01 00:00
Yea
r
Month Date Time
3B. Push SET ke
y
You will see curser under first di
g
it of the month
Use Arrow ke
y
to move curse
r
3C. Chan
g
e each di
g
it to toda
y
s month
,
date
,
and time
Exam
p
le Jul
y
4
,
2007 at 4:15PM
C
.2.007 07.04 16:15
3D. Push ENTR
Y
Ke
y
4. In
p
ut
(
Ran
g
e
)
Settin
g
(
See manual under Ran
g
e/
p
rintin
g
ran
g
e
)
4A. Choose In
p
ut and ran
g
e close to
y
our in
p
ut t
yp
e
Exam
p
le:K thermocou
p
le for 0/1000 F. Choose No. 22
4B. Push SHIFT + RANGE Ke
y
at same time
You will see Dis
p
la
y
of ori
g
inal factor
y
settin
g
R
.01:0700.00 5.00
Ran
g
e
Tem
p
erature com
p
ensation
(
CJ
)
Thermocou
p
le 1 other 0
Ran
g
e Number form above chart
In
p
ut channel number: RD2800= 2 di
g
it RD200= 1 di
g
it
4C. Push SET Ke
y
You will see Curser under Channel number.
Use Arrow ke
y
to move curse
r
4CA. Exam
p
le 1. settin
g
of Thermocou
p
le
(
K t
yp
e 0 to 2000 F
)
R
.01:2210 200.0
Push SPAC ke
y
to remove decimal
Thermocou
p
le alwa
y
s 1
Now Push ENTR
Y
ke
y
Dis
p
la
y
will chan
g
e to channel 02 and factor
y
settin
g
.
To chan
g
e the in
p
ut
,
re
p
eat of ste
p
1.
(
Re
p
eat 4CA
)
Alwa
y
s
p
ush ENTR
Y
ke
y
after each channel
p
ro
g
ram.
If all channel in
p
ut is same as Channel 1
,
then
,
after
p
ro
g
ramin
g
Channel 1 and
p
ush ENTR
Y
ke
y,
p
erform COPY
4CB. Push SHIFT + COPY ke
y
at same time
Curser under referance channel: move curser b
y
Arrow ke
y
S
.C o:P
Y
01=02. 12
Co
p
ied chnnel 1 settin
g
to channel 2 to 12
Push: Entr
y
Ke
y
dis
p
la
y
g
oes back to:
R
.12:2210 200.0
Show last channel
p
ro
g
ramed.
When all channel are
p
ro
g
ramed: Push SHIFT + END ke
y
***ENTRY Ke
y
onl
y
tos tore the chan
g
e
,
Shift + End ke
y
to chan
g
e
the
p
ro
g
ram and store.
4CD: Defult tem
p
erature is alwa
y
s de
g
rees C. If De
g
rees F is needed:
Push SHIFT + F ke
y
for lon
g
er then 3 second
.d EG.C d EG.F d EG.C
Push SE
T
Ke
y
Youw will see curser under dEG.C
To chan
g
e to De
g
. F
,
Push U
p
/down Arrow ke
y
.d EG.C d EG.F d EG.F
Push ENTR
Y
ke
y
(
no need to
p
ush SHIFT + END ke
y)
Push Dis
p
la
y
ke
y
to
g
o back to
p
ro
g
am dis
p
la
y
.
4CA
A
. mV
,
Volta
g
e and Current
(
4/20mA
)
in
p
ut
(
4/20mA in
p
ut
,
make sure 250 ohm resister is connected to the terminal
)
Push SHIFT + RANGE Ke
y
at same time
R
.01:0700.00 5.00
This is DC volta
g
e in
p
ut
Exam
p
le 4/20mA in
p
ut
Push Set Ke
y
You will see curser under channel nummber
,
move curser b
y
Arrow ke
y
. 4/20mA with 250ohm Resiter is 1-5V
R
.01:0701.00 5.00
Ran
g
e of 1 to 5V onl
y
use
CJ is alwa
y
s 0 for volta
g
e
,
current and RTD
Ran
g
e number form the chart -5 to 5 V
Push ENTR
Y
Ke
y
**After Entr
y
ke
y,
Channel chan
g
e to next channel number
**If not same in
p
ut
,
then enter the in
p
ut number and ran
g
e
(
4CA
)
**If all channel to be same in
p
ut
,
p
erform Co
py
function as above.
(
4CB
)
After all channel are
p
ro
g
ram
,
Push SHIFT + END ke
y
5. Scale
(
Min. and Max readin
g
of in
p
ut ran
g
e
)
(
see manual under Scale
)
**Thermocou
p
le Scale is noramll
y
same as Ran
g
e so no need to
p
erform
Scale
p
ro
g
rammin
g
.
5A. Exam
p
le 4/20mA in
p
ut with scale of 0 to 100
Push SHIFT + SCAL
E
ke
at same time
(
4/20mA was set as 1 to 5V
)
You will see dis
p
la
y
:
S
.1 5
Push SET ke
y
(
You will see curser under 1
)
Chan
g
e to followin
g,
movin
g
curser usin
g
Arrow ke
y
S
.0 100
Push ENTRY Ke
y
Channel number chan
g
e to next channel
**If next channel is different then
p
revious
,
p
erform chan
g
e then
p
ush ENTRY
***If all cahnnel Scale to be same
,
Perform Co
py
(
4CB
)
function
When all channela re
p
ro
g
ramed
,
Push SHIFT + END ke
at same time.
6. Chart S
p
eed
Factor
y
set chart S
p
eed is 20mm
p
er hour
To chan
g
e chart S
p
eed: Push SHIFT + CHAR
T
ke
at same time
H
CS 0020
Push SET ke
y
Chart S
p
eed
You will see curser under chart s
p
eed
Exam
p
le: chan
g
e to 2 inches
(
50mm
)
p
er hour
H
CS 0050
Push Entr
y
Ke
y
. This will store the chan
g
e
(
no need to
p
ush END ke
y
basic
p
ro
g
rammin
g
done
,
p
ush recorder ON and start recordin
g
/