Aruba JL585A User guide

Category
Networking
Type
User guide

This manual is also suitable for

HPE 5710-CMW710-R2612P11 Usage Guidelines
i
HPE 5710-CMW710-R2612P11
Usage Guidelines
Keywords: Version Information, Version changed, Unresolved Problems and Avoidance Measures, List of
Solved Problems
Abstract: Provide all details about the application version file, include: Version Information, Version
changed, Unresolved Problems and Avoidance Measures, List of Solved Problems
Abbreviations:
Abbreviations
Full spelling
IRF
Intelligent Resilient Framework
AAA
Authentication, Authorization and Accounting
ARP
Address Resolution Protocol
CMW
Comware
DHCP
Dynamic Host Configuration Protocol
LACP
Link Aggregation Control Protocol
MIB
Management Information Base
MSTP
Multiple Spanning Tree Protocol
SNMP
Simple Network Management Protocol
TCP
Transmission Control Protocol
VLAN
Virtual Local Area Network
RIP
Routing Information Protocol
ECN
Explicit Congestion Notification
HPE 5710-CMW710-R2612P11 Usage Guidelines
ii
Contents
Version information ···········································································1
Version number ··························································································································· 1
Version history ···························································································································· 1
Release reason ··························································································································· 1
Restrictions and cautions ···································································1
Open problems and workarounds ························································2
List of solved problems ······································································2
Resolved problems in R2612P11 ···································································································· 2
Resolved problems in R2612P10 ···································································································· 3
Resolved problems in R2612P08 ···································································································· 9
Resolved problems in R2612P06 ·································································································· 10
Resolved problems in R2612P05 ·································································································· 20
Resolved problems in R2612P03 ·································································································· 22
Resolved problems in R2612P01 ·································································································· 23
Resolved problems in R2612········································································································ 26
Resolved problems in R2611········································································································ 32
Software upgrade guidelines ···························································· 32
HPE 5710-CMW710-R2612P11 Usage Guidelines
1
Version information
Version number
Version number (outer): HPE Comware Software, Version 7.1.070, Release 2612P11
Version number (inner): V300R009B01D024SP26
Version history
Table 1 Version history
Version
number(inner)
Version
Number(outer)
Based Version
Number
Release Date
V300R009B01D0
24SP26
5710-CMW710-R
2612P11
5710-CMW710-R
2612P10
2022-10-15
V300R009B01D0
24SP25
5710-CMW710-R
2612P10
5710-CMW710-R
2612P08
2021-11-15
V300R009B01D0
24SP23
5710-CMW710-R
2612P08
5710-CMW710-R
2612P06
2020-02-17
V300R009B01D0
24SP20
5710-CMW710-R
2612P06
5710-CMW710-R
2612P05
2019-10-31
V300R009B01D0
24SP17
5710-CMW710-R
2612P05
5710-CMW710-R
2612P03
2019-03-18
V300R009B01D0
24SP16
5710-CMW710-R
2612P03
5710-CMW710-R
2612P01
2018-10-24
V300R009B01D0
24SP12
5710-CMW710-R
2612P01
5710-CMW710-R
2612
2018-08-24
V300R009B01D0
24SP09
5710-CMW710-R
2612
5710-CMW710-R
2611
2018-06-01
V300R009B01D0
24SP07
5710-CMW710-R
2611
First Release
2018-04-27
Release reason
Fixed bugs.
Restrictions and cautions
None.
HPE 5710-CMW710-R2612P11 Usage Guidelines
2
Open problems and workarounds
202110120988
Symptom: When a MAC authentication user comes online, the user matches an incorrect ACL.
Condition: This symptom occurs if the following operations are performed:
a. The device performs remote MAC authentication, and the server issues ACLs.
b. Multiple MAC addresses are issued to a port and they match multiple ACLs separately.
Workaround: Issue only one ACL to one port.
List of solved problems
Resolved problems in R2612P11
202209291102
Symptom: The MACsec process is abnormal.
Condition: This symptom occurs if the server NICs use the jumbo frame mode and the iNode
software with the MACsec function is customized on a client-oriented MACsec network.
202206240060
Symptom: When you use the display diagnostic-information command to collect diagnostic
information, the information collected is incomplete.
Condition: This symptom occurs if the display diagnostic-information command is used to
save diagnostic information.
202112240195
Symptom: All dynamic MAC address entries of the device cannot age out.
Condition: This symptom occurs if ARP entries with the same MAC address frequently move
between different ports, so the MAC address entry is frequently added and deleted on ports.
202203301472
Symptom: The subordinate IRF member device reboots unexpectedly.
Condition: This symptom occurs if the PTP master repeatedly changes the system time and
patches are installed and uninstalled on the subordinate IRF member device.
202112300661
Symptom: When NETCONF is used to read the /device/base node, an error is returned.
HPE 5710-CMW710-R2612P11 Usage Guidelines
3
Condition: This symptom occurs if NETCONF is used to read the /device/base node.
202112131411
Symptom: When NETCONF is used to read the /api/v1/Device/Transceivers node, an error is
returned.
Condition: This symptom occurs if NETCONF is used to read the /api/v1/Device/Transceivers
node.
Resolved problems in R2612P10
202006150267
Symptom: When a 10-GE interface on a 5710-30HT switch connects to a peer GE interface,
packet loss occurs.
Condition: This symptom occurs if a 10-GE interface on a 5710-30HT switch connects to a peer
GE interface.
202110271360
Symptom: CRC packets might be lost.
Condition: This symptom occurs if 100G IRF physical interfaces are connected through cables.
202109300800
Symptom: The return packets are not forwarded over the same path as the originating packets.
Condition: This symptom occurs if the originating packets are MPLS packets and are
decapsulated before being forwarded at Layer 3.
202003020695
Symptom: The system displays a message that reports incompatibility of two power modules.
Condition: This symptom occurs if either of the following conditions exists.
Two power modules of different models are installed on the device.
The system fails to read information from the EEPROM of a power module.
202109300799
Symptom: The display transceiver manuinfo command might fail to obtain the transceiver
module information with a low probability.
Condition: This symptom occurs if the following operations are performed:
a. Use a 10KM 10-Gbps BIDI transceiver module made by XGIAG.
b. Plug and unplug the transceiver module multiple times.
HPE 5710-CMW710-R2612P11 Usage Guidelines
4
202109300759
Symptom: 5710 switches are used to form an IRF fabric, and one end uses one of the first four
40-GE interfaces and the other end uses one of the last two 40-GE interfaces to form an IRF
physical link. CRC errors occur on the IRF link.
Condition: This symptom occurs if the following operations have been performed:
a. 5710 switches are used to form an IRF fabric.
b. One end uses one of the first four 40-GE interfaces and the other end uses one of the last
two 40-GE interfaces to form an IRF physical link. The IRF physical interfaces are
connected through copper cables.
202109300570
Symptom: The last six ports of the device fail to forward packets.
Condition: This symptom occurs if the following operations are performed:
a. Assign the first 48 10G ports to a VLAN as access ports or trunk ports. Assign one or
multiple of the last six 40G ports to the same VLAN as trunk ports.
b. Save the configuration file and reboot the device.
202109300496
Symptom: The Web interface does not display the interface management panel after the
Network > Interfaces > Panel or Network > Storm Constrain page is accessed.
Condition: This symptom might occur if the Network > Interfaces > Panel or Network > Storm
Constrain page is accessed.
202109300694/202109300687
Symptom: A user might fail to remotely log in to the switch.
Condition: This symptom occurs if the user logs in to the switch by using SSH or Telnet.
202109300560
Symptom: The device cannot be logged in through the console port or by using Telnet or SSH.
Condition: This symptom might occur if the following operations are performed:
a. A non-console user logs in to the device and enters FTP client view. Then, the user exits
from the view and closes the console at the same time. After the operations, the device has
residual FTP processes.
b. Configure AAA commands on the device. AAA processes are stuck.
202109300735
Symptom: The device reboots unexpectedly.
Condition: This symptom occurs if the following operations are performed:
a. Access the device through SSH repeatedly.
HPE 5710-CMW710-R2612P11 Usage Guidelines
5
b. Configure the device to permit SSH packets and then configure the device to deny SSH
packets repeatedly.
202109300806
Symptom: The device cannot ping a directly connected device.
Condition: This symptom occurs if the VXLAN hardware resource mode of the device is l2gw
and the interface connected to the interface on the directly connected device has QinQ settings.
202109300803
Symptoms:
No NQA operation result is available if you display the result immediately after the NQA
operation starts.
The NQA result shows that the delay time is relatively long.
Conditions:
The first symptom occurs if you display the result immediately after the NQA operation
starts.
The second symptom occurs when a large number of NQA operations are running
simultaneously.
202109300793
Symptom: Few MPLS packets are dropped.
Condition: This symptom occurs if the routes are updated after session protection is enabled in
LDP view.
202109300790
Symptom: IPC packets cannot be forwarded between IRF master and subordinate devices. The
original master device cannot join the IRF fabric after a reboot. In addition, users cannot log in
to the IRF fabric through the console port.
Condition: This symptom might occur if the IRF physical interfaces and other common network
interfaces are flapping.
202109300722
Symptom: The device might reboot unexpectedly.
Condition: This symptom occurs if multiple task request MBUF resources at the same time.
202109300552
Symptom: On the Web interface, the available member ports that can be assigned to a Layer 3
aggregation group are Layer 2 physical interfaces.
Condition: This symptom might occur if a Layer 3 aggregate interface is modified to add
member ports to it on the Web interface.
HPE 5710-CMW710-R2612P11 Usage Guidelines
6
202109151249
Symptom: The device mistakenly reports that the memory usage reaches the early warning
threshold.
Condition: This symptom occurs if you modify the memory alarm threshold multiple times.
202109300755
Symptom: During cross-chassis VXLAN packet forwarding, IRF physical interfaces discard runt
frames (the packet length is less than 64 bytes), which causes incorrect statistics of runt
frames.
Condition: This symptom might occur if a subordinate device decapsulates VXLAN packets and
then forwards the packets to the master device during cross-chassis VXLAN packet forwarding.
202110080350/202103241343
Symptom: A VXLAN tunnel cannot forward traffic.
Condition: This symptom occurs if the source or destination IP of the VXLAN tunnel is
repeatedly modified.
202109300801
Symptom: Some of the traffic between a spine device and a leaf device might be lost.
Condition: This symptom occurs if the following operations are performed:
a. Two leaf devices form an IRF fabric. Two spine devices form an IRF fabric.
b. Connect each leaf device to the two spine devices to form a network with four uplinks and
four downlinks.
c. Execute the shutdown command on the user-side interfaces of the leaf devices.
202109300792
Symptom: In a VXLAN network, VMs in the same subnet might fail to ping one another after
certain operations are performed.
Condition: This symptom might occur if the following operations are performed:
a. Create an Ethernet service instance on an interface, configure the SVLAN ID match
criterion for it, and set the PVID of that interface to be the same as the SVLAN ID in the
match criterion.
b. Delete the Ethernet service instance.
c. Repeat steps a and b.
202109300788
Symptom: The broadcast or unknown unicast packets forwarded over a VXLAN tunnel are lost.
Condition: This symptom might occur if the VXLAN tunnel has multiple ECMP routes and the
nexthops for some of the routes flap.
HPE 5710-CMW710-R2612P11 Usage Guidelines
7
202109300779
Symptom: The switch is in an EVPN network. When receiving untagged packets from an AC,
the switch fails to send the packets to the controller.
Condition: This symptom might occur if the VSI interfaces on the switch are assigned IPv6
addresses and the switch receives untagged packets from an AC.
202109300805
Symptom: The traffic accounting units change from bytes and packets to only bytes in the traffic
accounting action of an applied QoS policy.
Condition: This symptom occurs if the following operations are performed:
a. Configure two QoS policies. In the two QoS policies, associate different traffic classes with
the same traffic behavior that is configured with the traffic accounting action. The traffic
accounting action counts packets in both bytes and packets.
b. Apply one QoS policy in the inbound direction of an interface, and apply the other QoS
policy in the outbound direction of the interface.
The traffic accounting units of the first applied QoS policy change from bytes and packets to
only bytes.
202109300794
Symptom: On a distributed EVPN gateway, traffic is not forwarded to the expected next hop
based on a PBR policy.
Condition: This symptom might occur if VSI interfaces receive continuous ARP request traffic.
202109300789
Symptom: A PBR policy does not take effect on an aggregate interface after certain operations
are performed.
Condition: This symptom might occur if the following operations are performed:
a. Apply a PBR policy to an aggregate interface and its member ports.
b. Delete the PBR policy from the aggregation member ports.
202109300749
Symptom: Transient packet loss occurs on an interface when the undo packet-filter command
is executed to remove an ACL from the interface.
Condition: This symptom might occur if the ACL has multiple rules and the action is set to deny
in the last rule.
202110100063
Symptom: 10-GE breakout interfaces fail to learn ARP entries.
HPE 5710-CMW710-R2612P11 Usage Guidelines
8
Condition: This symptom occurs if 10-GE breakout interfaces on an 5710 device are connected
to peer ports.
202109300802
Symptom: The device has a route, but it does not have an ARP entry for the next hop address in
the route and the device fails to ping the next hop address.
Condition: This symptom might occur if a route with a reachable next hop address is configured
and then the next hop address is changed to another IP address.
202109300791
Symptom: On a distributed EVPN gateway, traffic is not forwarded to the expected next hop
based on a PBR policy.
Condition: This symptom might occur if VSI interfaces receive continuous ARP request traffic.
202109300797
Symptom: Output from the display l2vpn mac-address command does not contain
information about some VSIs, which does not affect forwarding entry learning or traffic
forwarding.
Condition: This symptom might occur if SPBM configuration exists.
202109300795
Symptom: On an IRF fabric deployed with PBR policies, resources on a subordinate device are
insufficient and packet forwarding exceptions occur on the device.
Condition: This symptom might occur if the following conditions exist:
Service chain rules are configured in PBR actions.
The next hops of PBR policies are flapping.
202109300771
Symptom: The switch cannot ping a server that is connected to an interface AC.
Condition: This symptom might occur if an interface is removed from an aggregation group and
then configured as an AC.
202111091539
Symptom: An ACL applied to an aggregate interface for packet filtering does not take effect.
Condition: This symptom occurs if the following operations are performed:
Apply an ACL with many rules to the aggregate interface. This ACL occupies the resources
of slice 6 and slice 7.
Apply a second ACL to the aggregate interface. This ACL occupies the some resources of
slice 4.
Delete some rules from the first applied ACL to release some resources of slice 6.
HPE 5710-CMW710-R2612P11 Usage Guidelines
9
Apply a third ACL to the aggregate interface. This ACL occupies the remaining resources of
slice 4 and the released resources of slice 6. This ACL does not take effect.
202111091536
Symptom: uRPF cannot be enabled or disabled on an aggregate interface when the device is
operating in l2gw hardware resource mode.
Condition: None.
202111091527
Symptom: For a 40-GE interface manually shut down, a 10-GE transceiver module inserted into
this interface by using a 40-GE to 10-GE adapter can transmit optical signal correctly. After the
transceiver module is removed and reinstalled in the 40-GE interface, the interface comes up.
Condition: This symptom occurs when the following operations have been performed:
a. Execute the shutdown command on the 40-GE interface.
b. Insert a 40-GE to 10-GE adapter into the 40-GE interface.
c. Insert a 10-GE transceiver module into the adapter and connect the interface to a peer
device.
d. Remove and reinstall the 10-GE transceiver module in the interface.
202111080580
Symptom: A backup device in a VRRP group mistakenly reserves a VRRP virtual MAC address
as an interface MAC address
Condition: This symptom might occur if VRRP is configured to operate in non-preemptive mode
on the device and the VRRP process is restarted in a specific order.
202111121583
Symptom: Packet statistics on VSI interfaces cannot be displayed.
Condition: This symptom occurs if the display interface vsi-interface command is used to
display information about VSI interfaces.
Resolved problems in R2612P08
202001070563
Symptom: Some of the traffic between a spine device and a leaf device might be lost.
Condition: This symptom occurs if the following operations are performed:
a. Two leaf devices form an IRF fabric. Two spine devices form an IRF fabric.
b. Connect each leaf device to the two spine devices to form a network with four uplinks and
four downlinks.
c. Execute the shutdown command on the user-side interfaces of the leaf devices.
HPE 5710-CMW710-R2612P11 Usage Guidelines
10
202001061065
Symptom: The configuration file of the subordinate IRF member device is lost. As a result, the
IRF fabric fails to be established.
Condition: This symptom occurs if one of the following conditions exists:
Execute the save command on the device. Exit the console before the save operation is
completed.
Execute the save command through NETCONF. Disconnect the NETCONF session before
the save operation is completed.
201912230025
Symptom: The packet statistics for VLAN interfaces and VSI interfaces are incorrect.
Condition: This symptom occurs if packet statistics are collected for VLAN interfaces and VSI
interfaces.
202001100912
Symptom: Interfaces on an LSWM124XGT2Q expansion module cannot be used.
Condition: This symptom occurs if an LSWM124XGT2Q expansion module is
unplugged/plugged or restarted.
201908120355
Symptom: An interface cannot come up after going down.
Condition: This symptom occurs if the following operations are performed:
a. The interface has MACsec enabled and operates at 1 Gbps.
b. The interface goes down.
201912310648
Symptom: The dbmd process might exit abnormally with an extremely low probability. As a
result, the configuration of the device might become empty.
Condition: This symptom occurs if a command is repeatedly executed to view the memory
usage of the dbmd process.
Resolved problems in R2612P06
201910080441
Symptom: Transient packet loss occurs on an interface when the undo packet-filter command is
executed to remove an ACL from the interface.
Condition: This symptom might occur if the ACL has multiple rules and the action is set to deny
in the last rule.
HPE 5710-CMW710-R2612P11 Usage Guidelines
11
201908020287
Symptom: Some settings of a PBR policy do not take effect after the PBR policy is modified.
Condition: This symptom might occur if the match criteria of multiple nodes are configured and
new nodes are added for the PBR policy.
201910291002
Symptom: The vtep access port command configuration is lost on an aggregate interface.
Condition: This symptom occurs after you modify the system name of the server after the switch
comes online through automatic deployment.
201907011027
Symptom: After a server migrates from a DR interface to a non-DR interface on the primary
member device of a DR system, the server cannot ping the gateway attached to the DR system.
Condition: This symptom might occur if a server migrates from a DR interface to a non-DR
interface on the primary member device of a DR system.
201902220722
Symptom: In a VCF fabric, IP addresses are re-assigned to Loopback 0 interfaces after leaf
nodes automatically form an IRF fabric.
Condition: This symptom might occur if the switch as a leaf node joins the IRF fabric
automatically formed by other leaf nodes.
201909020134
Symptom: In a VXLAN network, VMs in the same subnet might fail to ping one another after
certain operations are performed.
Condition: This symptom might occur if the following operations are performed:
a. Create an Ethernet service instance on an interface, configure the SVLAN ID match
criterion for it, and set the PVID of that interface to be the same as the SVLAN ID in the
match criterion.
b. Delete the Ethernet service instance.
c. Repeat steps a and b.
201908260088
Symptom: An NMS cannot access the switch through SNMP after accessing the
hh3cTunnelVxlanIfEntry node.
Condition: This symptom might occur if the switch has VXLAN-DCI tunnels and an NMS
accesses the hh3cTunnelVxlanIfEntry node.
HPE 5710-CMW710-R2612P11 Usage Guidelines
12
201908130087
Symptom: A VXLAN VTEP forwards the ARP packets received from a VXLAN tunnel to other
VXLAN tunnels.
Condition: This symptom might occur if a VXLAN VTEP receives ARP packets from a VXLAN
tunnel.
201907080547
Symptom: A peer cannot learn the management IP address of the switch through LLDP after
the LLDP process restarts on the switch.
Condition: This symptom might occur if the LLDP process restarts on the switch.
201907080194
Symptom: After the qos trust dscp command is executed on an interface, the interface
modifies the 802.1p priority of outgoing packets.
Condition: This symptom might occur if the qos trust dscp command is executed on an
interface.
201907110305
Symptom: When MAC authentication is disabled on an interface, the MAC address entries
generated for MAC authentication are not deleted from the interface, but these entries can age
out.
Condition: This symptom might occur if MAC authentication is disabled on the interface where
MAC authentication has been performed on users.
201907050600
Symptom: The switch does not respond to commands issued through NETCONF.
Condition: This symptom occurs if the commands are issued quickly without delays between
them.
201907060001
Symptom: The switch fails IRF fabric setup when certain conditions exist.
Condition: This symptom might occur if the following conditions exist on the switch:
The maximum number of ECMP routes is set to a non-default value.
When the switch is rebooted without loading a configuration file, the current maximum
number of ECMP routes is inconsistent with the value that will take effect at next startup.
201907050681
Symptom: After the LLDP process is restarted, the vtep access port configuration on aggregate
interfaces is lost.
HPE 5710-CMW710-R2612P11 Usage Guidelines
13
Condition: This symptom occurs if the device is automatically configured and the LLDP process
is restarted.
201907050645
Symptom: After the IRF fabric is automatically configured and then the subordinate IRF
member device is rebooted, the shutdown configuration of interfaces on the subordinate IRF
member device is lost.
Condition: This symptom occurs if the IRF fabric is automatically configured and then the
subordinate IRF member device is rebooted.
201907050643
Symptom: A memory leak occurs on the SNMP process.
Condition: This symptom occurs if the following conditions exist:
a. SNMP notifications for system logs are disabled.
b. The NMS walks the SYSLOG-MSG-MIB to obtain data.
201908120212
Symptom: Traffic might fail to be forwarded between VXLANs.
Condition: This symptom occurs if the following operations are performed:
a. The VCFC controller deploys configurations to spine and leaf devices.
b. On a leaf device, multiple VXLANs are configured, and a large number of VMs come online.
c. A large number of VMs migrate to other VXLANs.
201907300713
Symptom: An interface configured with a PBR policy flaps and the PBR policy no longer takes
effect when ECMP is configured on the interface.
Condition: This symptom might occur if ECMP is configured on an interface where a PBR policy
is applied.
201907050725
Symptom: Interface flapping might cause route refresh failure and forwarding failure.
Condition: This symptom might occur if interface flapping occurs.
Remarks: After patch installation, shut down and bring up related interfaces to resolve this
problem.
201907050723
Symptom: Layer 3 packets of a VSI fail to be forwarded out of a different VSI on another device.
Condition: This symptom occurs in a distributed VXLAN IP gateway deployment.
HPE 5710-CMW710-R2612P11 Usage Guidelines
14
201907050651
Symptom: The BGP process might exit and the service is interrupted at a low probability.
Condition: This symptom occurs if the following conditions exist:
ND flood suppression is configured on a VSI.
The device receives a large number of ND packets on the corresponding AC interface,
generates ND flood suppression entries and synchronizes the entries to the remote end.
The corresponding VXLAN is repeatedly created and deleted on the remote end.
201907020286
Symptom: A user fails MAC authentication on an interface if its MAC address has been learned
by another interface of the switch.
Condition: This symptom might occur if a MAC authentication user accesses an interface and
its MAC address has been learned by another interface of the switch.
201908300426
Symptom: An Ethernet fiber port installed with a transceiver module fails to come up.
Condition: This symptom occurs with a low probability if the Ethernet fiber port is on the device
or on an interface module and has a transceiver module installed.
201908060024
Symptom: The status of the interface on the switch becomes inconsistent with that of the peer
interface on the directly connected device after the peer interface goes down and then
immediately comes up.
Condition: This symptom might occur if the peer interface on the directly connected device goes
down and then immediately comes up.
201907050641
Symptom: Interface flapping might cause route refresh failure and forwarding failure.
Condition: This symptom might occur if interface flapping occurs.
Remarks: After patch installation, shut down and bring up related interfaces to resolve this
problem.
201909100470
Symptom: Some VMs attached to a DRNI system have traffic loss.
Condition: This symptom might occur if the RARP protocol packets sent by VMs are forwarded
through the IPL.
201907080567
Symptom: Multiple Telnet users exist and cannot be deleted after certain operations are
performed.
HPE 5710-CMW710-R2612P11 Usage Guidelines
15
Condition: This symptom might occur if the following operations are performed:
a. Telnet to the switch from multiple terminals.
b. On each terminal, execute the telnet 127.0.0.1 command multiple times and press Ctrl + K.
c. Execute the display users command on the switch.
201906280854
Symptom: Both CLI-configured and controller-issued VSIs exist on the switch. When the
running configuration is saved and then the switch is rebooted, some CLI-configured VSIs are
lost.
Condition: This symptom might occur if VSIs are configured both at the CLI and from the
controller and the switch is rebooted.
201908270381
Symptom: After an 802.1X passes authentication, the issued authorization ACL does not take
effect.
Condition: This symptom occurs if 802.1X authentication is configured and an authorization
ACL is specified.
201908050996
Symptom: The switch learns the source MAC address of LLDP packets.
Condition: This symptom occurs if LLDP is enabled on an interface.
201908010131
Symptom: A 10-GE breakout interface on an 5710 switch fails to establish an LLDP neighbor
relationship with the peer interface.
Condition: This symptom occurs if the switch is configured with LLDP and uses a 10-GE
breakout interface to establish an LLDP neighbor relationship with the peer interface.
201907080541
Symptom: The console is stuck after a large number of ACLs and VPN instances are
configured.
Condition: This symptom occurs if the following operations are performed:
a. Create a large number of ACLs and configure a large number of rules for them.
b. Create a large number of VPN instances.
201910100184
Symptom: The switch reboots when it synchronizes the clock from an NTP server.
Condition: This symptom might occur if the year on the NTP server is later than year 2068.
HPE 5710-CMW710-R2612P11 Usage Guidelines
16
201907310567
Symptom: The VFC interface on the master device in an IRF fabric is displayed as physically up
and protocol down on the subordinate after an IRF split.
Condition: This symptom occurs in an IRF fabric formed by FCF switches.
201907160049
Symptom: After MPLS is disabled on an interface, packets forwarded by the interface still carry
labels.
Condition: This symptom occurs if the LDP session flaps.
201907160048
Symptom: In an MPLS network, switching operations between ECMP routes take different
amounts of time, ranging from 0 to 30 seconds.
Condition: None.
201907080633
Symptom: The switch reboots when a subinterface is deleted repeatedly.
Condition: This symptom might occur if the subinterface is configured with the TCP MSS.
201907080562
Symptom: In a weak-control ADDC network, the spine device cannot obtain a loopback address
from the controller.
Condition: This symptom occurs if the spine device is connected to two or more leaf devices
that do not have automatic topology discovery capabilities.
201907080542
Symptom: A BFD session on an MPLS TE tunnel interface is created and deleted repeatedly
when the tunnel interface flaps.
Condition: This symptom might occur if the MPLS TE tunnel is created through RSVP and BFD
for RSVP is enabled on the tunnel interface by using the rsvp bfd enable command.
201903210604
Symptom: The device might reboot unexpectedly.
Condition: This symptom might occur if multiple users concurrently log in to the device and the
display transceiver information interface or display transceiver moduleinfo interface
command is executed in probe view.
201907290487
Symptom: A host fails to ping the gateway.
Condition: This symptom might occur if a PBR policy is configured to specify the next hop of the
route for the network segment where the host resides.
HPE 5710-CMW710-R2612P11 Usage Guidelines
17
201907080584
Symptom: The device might reboot unexpectedly.
Condition: This symptom might occur if the device is obtaining information about an ARP entry
through SNMP while the kernel is deleting the ARP entry.
201904100945
Symptom: On a DRNI network, the packet loss duration on a DR interface exceeds 200 ms.
Condition: This symptom might occur after the DR interface switches to a different interface.
201906170899
Symptom: L2PT for UDLD does not take effect.
Condition: This symptom might occur if the l2protocol udld tunnel dot1q command is
executed to enable L2PT for UDLD.
201903210129
Symptom: Part of the mirroring group configuration gets lost after an ISSU upgrade.
Condition: This symptom might occur if ISSU is performed to upgrade the software version from
R2510P01 to R2612P02 or later.
201907080553
Symptom: An LSP on an interface still remains after LDP is disabled on the interface.
Condition: This symptom might occur if two LSPs are primary and backup LSPs for the same
network segment and LDP is disabled on the interface of the primary LSP.
201907080537
Symptom: The server is permanently blocked and cannot recover to the active state.
Condition: This symptom occurs if the authentication server state is set to block and two
active/standby switchovers are performed before the server recovers to the active state.
201907080523
Symptom: When the controller deploys abnormal entries to the OpenFlow device, the
OpenFlow device reboots unexpectedly.
Condition: This symptom occurs if the following operations have been performed:
a. Enable the global mode for an OpenFlow instance.
b. Configure an MAC-IP flow table.
c. Connect the device to the controller.
d. Activate the OpenFlow instance.
201907080505
Symptom: The CLI gets stuck when link aggregation-related commands are executed.
HPE 5710-CMW710-R2612P11 Usage Guidelines
18
Condition: This symptom occurs if the following operations have been performed:
a. Enable BFD for an aggregation group.
b. The corresponding aggregate interface receives Layer 2 broadcast traffic, which causes
BFD session flapping.
201910120649
Symptom: PBR configuration does not take effect.
Condition: This symptom occurs if the following operations have been performed:
a. Create a multi-hop service chain on the controller.
b. Execute the apply service-chain command for a PBR policy node.
201908010004
Symptom: The VRRP group virtual MAC addresses cannot be successfully deployed.
Condition: This symptom occurs if the total number of VRRP groups on the device exceeds
512.
201909170276
Symptom: On an OVSDB network, the controller might mistakenly delete the Ethernet service
instance configuration of interfaces.
Condition: This symptom occurs if the following operations have been performed:
a. Use the Nuage controller on the network. The devices form an IRF fabric to
act as a VTEP.
b. Execute the vtep access port command on interfaces of the active MPU and standby
MPU.
c. Perform a master/subordinate switchover on the IRF fabric.
201909100187
Symptom: The drni mad exclude command configuration does not take effect. The keepalive
link and DR member device role flap repeatedly.
Condition: This symptom occurs if the following operations have been performed:
a. Exclude the interfaces used for keepalive detection from the shutdown action by DRNI MAD,
save the configuration, and recover the configuration from an .mdb configuration file.
b. Restart the drni process.
201907080635
Symptom: An IRF fabric gets into deadlock.
Condition: This symptom occurs with a low probability if a larger number of tunnels are created
and the IRF fabric repeatedly performs master/subordinate switchover .
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Aruba JL585A User guide

Category
Networking
Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI