Sensio LED0003 Installation guide

Type
Installation guide
Sensio House, Unit 7, Speedwell Road, Whitwood, Castleford, West Yorkshire, WF10 5PY
www.sensio.co.uk
Technical drawings for illustraon purposes only, Sensio has the right to change any informaon without
prior noce.
Waste Electrical & Electronic Equipment (WEEE)
The symbol on the product, or on the document accompanying the product, the crossed out wheelie
bin symbol, indicates that this product may not be treated as household waste.
Instead it shall be handed over to the applicable collecon point for the recycling of electrical and
electronic waste.
3. Never exceed the total output of a LED driver or receiver.
4. Suitable for furniture lighng.
5. Class III safety extra low voltage (SELV).
1. This product is only suitable for connecng to Sensio LED lights and
ngs.
2. Always read the installaon guide of any product used in conjuncon
with this product.
Safety Instrucons
Please read these instrucons carefully before aempng to install this
product. It is advisable to keep these instrucons in a safe place for future
reference.
We recommend that you consult a qualied electrician. All electrical
installaon must be carried out in accordance with current IEE wiring
regulaons (BS7671).
These p
These products must not be modied, if any modicaon are made, it may
invalidate the warranty and may render the product unsafe. These LED
lights operate low voltage (24V).
• Install on smooth at surface(s) only.
• Do not exeed or stretch the cable length of each wire.
This product is IP20 Rated.
Important Safety Informaon
Technical Specicaon
Screwdriver
1 x Instrucons
Manual
2 x Screws
(SE79095 &
SE79195 Only)
Magnet & Reed Switch
( SE79095 & SE79295 Only)
Receiver
(SE79095 & SE79195 Only)
Tools Required
Components
IMPORTANT: Please read these instrucons before commencing installaon and retain for future reference.
INSTALLATION
INSTRUCTIONS
Product Codes:
SE79095 - Link-S - Receiver, Magnet and Reed Switch
SE79195 - Link-S - Receiver
SE79295 - Link-S - Magnet & Reed Switch
Link-S - Receiver, Magnet
and Reed Switch
Lighng Control
Sensio V3
UK Address: Sensio Ltd, Unit 7, Speedwell Road, Castleford, West Yorks, WF10 5PY
EU Rep.: Sensio Lighting Dublin Ltd, The Black Church, St. Mary's Place, Dublin, Ireland, D07 P4AX
Sensio - V4
Technical drawings for illustraon purposes only, Sensio has the right to change any informaon
without prior noce.
Sensio V3
www.sensio.co.uk
Sensio House, Unit 7, Speedwell Road, Whitwood, Castleford, West Yorkshire, WF10 5PY
Ensure that the power is disconnected prior to cleaning.
To keep the nish of this product, wipe over with so cloth periodically.
Do not use harsh chemical solvents, this may dis-colour or damage the nish.
Do not over-ghten screws on the terminal block.
Maintenance & Care
Connect your light to the receiver by inserng
the male-ended JB4 cable into the female-end.
Receiver - Underside View
Synchronizaon BuonSignal LED
To clear the memory of the
receiver, press the
synchronizaon buon with
a sharp object for ve
seconds. The signal LED will
icker once.
2
Move the magnet apart
from the reed switch
and then touch them
again. The signal LED
will icker once when
pairing is complete.
Press the synchronizaon
buon on the underside of
the receiver with a sharp
object. The signal LED will
icker once.
1
Each receiver can connect with up to ve
magn
magnets and reed switches. The recommended
scenario for this setup would be to have a
magnet and reed switch on a series of cabinet
doors. Opening each cabinet door would then
trigger all the lights connected to the receiver.
For example, a series of in-cabinet lights.
E
Each magnet and reed switch can be connect
with up to ve dierent receivers. The
recommended scenario for this setup would be
to install the magnet and reed switch on the
door to a room. Opening the door will then
trigger all the lights connected to the receivers.
For example, all of the lighng in that room.
Operaon
Driver
Receiver
4
Secure the receiver in posion using the screws
included. Finally, connect the driver to the
mains supply.
Receiver
5
Connect the male-ended cable from the
receiver into the LED Driver.
Driver
Receiver
3
Peel the adhesive backing tape o of the
magnet and sck it into a posion where it will
make contact with the Reid switch when the
doors are closed. Note: The magnet can make
contact with the side of the Reid switch.
Reid
Switch Magnet
Magnet
2
Peel the adhesive backing tape o of the Reid
switch and sck it in your desired locaon.
Note: The product is suitable for installaon in
many scenarios, please ensure that you
measure and plan before installaon.
1
Reid Switch
Installaon
Link-S - Receiver, Magnet and Reed Switch
If you are installing a Sensio Wireless Magnec
Contact and Receiver with mulple Reid switch-
es and magnets, simply follow stages 1 and 2
for installaon. Once installed, each switch will
trigger the lighng when the two components
break contact.
UK Address: Sensio Ltd, Unit 7, Speedwell Road, Castleford, West Yorks, WF10 5PY
EU Rep.: Sensio Lighting Dublin Ltd, The Black Church, St. Mary's Place, Dublin, Ireland, D07 P4AX
Sensio - V4
  • Page 1 1
  • Page 2 2

Sensio LED0003 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI