Specifications PRIMO-II-48
PRIMO ll 48
Direct Vent Gas Fireplace
Scan QR code for
installation manual
for final dimensions
and requirements.
9-1/8"
[232]
18-1/4"
[464]
8" [203]
6" [152]
OUTSIDE AIR INTAKE
PRIMO-HEAT-DUCT
17-1/16"
[433]
5-3/8" [137]
9-7/16
"
[240]
2-3/4
"
[70]
7
"
[178]
2-7/16
"
[62]
GAS
ACCESS
ELECTRICAL
ACCESS
4" [102] 15-7/8"
[403]
18"
[457]
33-15/16"
[862]
40-13/16"
[1037]
9-5/16"
[237]
GAS / ELECTRIC CONNECTION
CARRY-HANDLE
BRACKETS
(BOTH SIDES)
5/8
"
[16] 5/8
"
[16]
64-3/8" [1635]
54-3/16" [1375]
48" [1219]
67-3/16" [1707]
44-5/8" [1134]
ACTUAL
DIMENSIONS
FRONT WIDTH HEIGHT DEPTH GLASS SIZE BTU/HOUR INPUT
64-3/8" [1635] 40-13/16" [1037] 18-1/4" [464] 48" x 18"
[1219 X 457]
31,500 - 45,000 BTUs (NG)
31,000 - 42,000 BTUs (LP)
TOP VIEW
FRONT VIEWLEFT SIDE RIGHT SIDE
FRAMING
DIMENSIONS
FRONT WIDTH HEIGHT DEPTH WEIGHT
66-3/4" [1695] 45" [1143] 18" [457] 375 LBS [170 KGS]
66-3/4"
[1695]*
DVP pipe 10" [254]
SLP pipe 9" [229]
HEADER
DEPTH**
45"
[1143]
18" [457]*
APPLIANCE MAY
BE INSTALLED
OFF OF FLOOR***
*Adjust framing dimensions for interior
chase sheathing (such as 1/2" drywall)
** Header depth not to exceed 5-1/2".
If header depth is greater than 3-1/2",
header must be notched in order to
maintain clearance to pipe.
*** If appliance is installed off of
floor, maintain required clearances to
combustibles. Construct platform in
accordance to local building codes.
64"
[1626]
28"
[711] 1" [25]
90-1/2" [2299]
1"
[25]
66-3/4" [1695]
Reference install manual for additional venting scenarios
BASIC CORNER INSTALLATION