Leica PELORIS Owner's manual

Type
Owner's manual
Easy to use Unique ActivFlo technology
Consumables,
Capacity and throughput Consistent quality
Cassettes Maximum reagent fl ow No block scraping
Solid wax blocks
safer, simpler, smarter.
Rapid processing,
high quality results, any tissue.
It’s about time
Peloris has unmatched speed. Its unique ActivFloTM system creates
rapid temperature rise and active reagent exchange. The result is
rapid processing for all tissue.
It’s about workflow
With speed, fl exibility and capacity, Peloris creates
the perfect Lean workfl ow in any lab.
It’s about patient care
ActivFlo generates ideal retort conditions (no hot spots or
stratifi cation). Pathologists enjoy consistent staining.
Patients benefi t from accelerated diagnosis.
Flexible protocols Peloris leads a new era of rapid tissue processing. It is fast, fl exible and produces high quality results for any tissue.
Now all laboratories can confi dently accelerate their entire diagnostic workfl ow.
System Specifications
Leica PELORISTM
Rapid Tissue Processing
Leica Microsystems - an international company
with a strong network of customer services
Peloris is available through the following offi ces:
Asia/Pacifi c
Sales orders/Customer support Aus 1800 246 797
Sales orders/Customer support NZ 0800 400 589
Europe/Middle East/Africa
Sales orders/Customer support UK 0800 298 2344
Sales orders/Customer support ROI 1800 242 612
Sales orders/Customer support EU +44 1908 246 246
North America
Sales orders/Customer support USA 800 248 0123
Sales orders/Customer support Canada 800 205 3422
The statement by Ernst Leitz in 1907, “with the user, for the user,” describes the fruitful collaboration
with end users and driving force of innovation at Leica Microsystems. We have developed fi ve
brand values to live up to this tradition: Pioneering, High-end Quality, Team Spirit, Dedication to
Science, and Continuous Improvement. For us, living up to these values means: Living up to Life.
Leica Microsystems operates globally in four divisions,
where we rank with the market leaders.
Life Science Division
The Leica Microsystems Life Science Division supports the
imaging needs of the scientifi c community with advanced
innovation and technical expertise for the visualization,
measurement, and analysis of microstructures. Our strong
focus on understanding scientifi c applications puts Leica
Microsystems’ customers at the leading edge of science.
Industry Division
The Leica Microsystems Industry Division’s focus is to
support customers’ pursuit of the highest quality end
result. Leica Microsystems provide the best and most
innovative imaging systems to see, measure, and analyze
the microstructures in routine and research industrial
applications, materials science, quality control, forensic
science investigation, and educational applications.
Biosystems Division
The Leica Microsystems Biosystems Division brings
histopathology labs and researchers the highest-quality,
most comprehensive product range. From patient to
pathologist, the range includes the ideal product for each
histology step and high-productivity workfl ow solutions for
the entire lab. With complete histology systems featuring
innovative automation and NovocastraTM reagents, Leica
Microsystems creates better patient care through rapid
turnaround, diagnostic confi dence, and close customer
collaboration.
Surgical Division
The Leica Microsystems Surgical Division’s focus is to
partner with and support surgeons and their care of
patients with the highest-quality, most innovative surgical
microscope technology today and into the future.
www.leica-microsystems.com
© Leica Microsystems GmbH HRB 5187 05/2009 95.7792 Rev C
Instrument
Instrument dimensions (h x w x d) . . . . . . . . . . . 1,500 x 857 x 721 mm
59 x 33.7 x 28.4 in
Cassette capacity . . . . . . . . 600 (maximum) 432 (spaced/xylene-free)
Retorts . . . . . . . . . . . . . . . . . 2 (allows for continuous processing)
Reagent stations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Embedding Molds
Stainless steel box of 12, 5 sizes . . . . . . . . No block scraping reusable
Disposable box of 500, 4 sizes . . . . . . . . No block scraping no cleaning
Reagents
Wax blocks box of 5 . . . . . . . Solid wax blocks rapid melt, easy handling
WaxsolTM 5 L (europe) 10 L (rest of world) . . . Xylene-free cleaning solution
Living up to Life
Preparation
Rapid Processing
Tissue Care
Diagnosis
Lab Management
Lean Workfl ow
Cytokeratin 7 (RN7)
and beyond...
C
os
t
Cos
CH3
CH3
Skin H&E
Conventional
Processor
T
em
p
T
T
Ti
me
Peloris
Mins
˚C/˚F
Estrogen Receptor 6F11 (ER-6F11)
ActivFlo with Peloris cassettes
More time at ideal temperature
Reduce reagent costs
PELORIS
TM
Peloris accelerates the diagnostic process. Processing
times are reduced, diagnostic clarity is enhanced, the
entire laboratory is streamlined. Speed, quality, fl exibility.
When the work fl ows, new possibilities emerge. Lean
management, same-day diagnosis, better patient care.
Eliminate xylene
Rapid Setup
Any tissue type or size
No additional grossing
No pre-processing step
Intelligent system
Very easy to use
Ve
ry
y
Fewer reagent changes
Sm
art consumable
s
Eliminate biopsy p
ad
s
(biopsy cassette
s)
Ea
sy wax transfer and rapid me
lt
(w
ax blocks)
Unmatched Speed
Accelerated protocols
40 – 60% faster than conventional
processors
Faster than microwaves
Fatty breast in 5 – 6 hours
Ideal Retort Conditions
Unique ActivFlo
Unique ActivFlo
TM
TM
System
System
No temperature stratifi cation
No temperature stratification
No hot spots
Active reagent exchange
High quality results
Morphology preservation
Eliminate reprocessing
Easier sectioning
uous Processing
Contin
u
es
ss
cient
Fa
st and E
ffi
mall-batch processing
Rapid
sm
roc
ess
ant sample stream
A
cons
ta
ple
rea
Control
Co
mplete
C
Contr
ide protocol duration
Yo
u deci
You de
You decide
ide each batch size (1 to 600)
Yo
u de
ci
e the Entire Laboratory
St
reamli
ne
te workfl ow peaks
Elim
in
at
s ready when they’re needed
Sample
s
e more output with existing
Ac
hiev
e
ome and embedding stations
microt
o
Everybody Benefi ts
Fl
exib
le
Workfl ow choices – continuous processing
an
d
overnight ru
ns
Reagent choices – xylene-free or xylene
Match runs to staff availabi
li
ty
Lean
Maximize reagent life
Eliminate workfl ow bottlenecks
Safe
Xylene-free processing
Eliminate molten wax transfe
r
Confi dence and Clarity
Id
eal for any stain
Routine, special, IHC and ISH
No
change to staining protocol
s
Constant quali
ty
N
ew Possibilities
Be
tter Patient Car
e
Eliminate repeat procedures
Same-day diagnosis
Reduce patient anxiety
S
tart treatment soone
r
Improved hospital administration
Earlier patient admission/dischar
ge
Reduced inpatient time
R
ed
uc
ed
i
np
at
ie
nt
time
50 mins
80 mins
1 hr 2 hrs
8 hrs
2 hrs 4 hrs
Rapid
processing
Peloris
Microwave
Conventional
1.5 mm
3 mm
6 mm 3 hrs
  • Page 1 1
  • Page 2 2

Leica PELORIS Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document