Amana High Capacity Room Air Conditioner Installation guide

Type
Installation guide
Introduction
Amana High Capacity Room Air Conditioners can be
installed through a wall or in a window. Window
installations require an Instant Mount Mounting Kit (model
number RAWK2). Window mounting kits are available at
(or through) Authorized Amana Dealers.
This instruction sheet provides guidelines for installing air
conditioner through an outside wall.
CAUTION
!
Installing air conditioner through a wall requires
extensive carpentry and/or masonry experience.
Through wall installations performed by inexperienced
or unqualified individuals can result in costly damage
to home.
Air Conditioner Dimensions
The following figures show the outside dimensions of air
conditioner with chassis installed, and dimensions of outer
case with chassis removed. Dimensions shown are with
the top rail removed (bottom rail on case is permanently
attached and is included in height dimensions).
31¼"
26¾"
Air Conditioner Dimensions
(with chassis installed)
Thru-wall Installation Instructions
for Amana High Capacity Room Air Conditioner
June 1998
25
3
/
8
"
28½"
14¾
17
3
/
16
"
19½"
Outer Case Dimensions
(chassis removed)
General Instructions
All Amana High Capacity Room Air Conditioners feature a
slide-out chassis. Chassis must be removed from outer
case for installation.
A finished opening 25
7
/8-inches wide x 20-inches high is
recommended (this provides a finished opening ¼-inch
larger than the outer case on all sides). The lower left
inside corner of opening must be within 5 feet of an
appropriate electrical outlet (see Use and Care manual for
air conditioner electrical requirements.)
Install outer case with a
3
/8-inch slope to the outside to
ensure proper condensate drainage. Caulk completely
around outside of unit to ensure it is properly sealed.
Depending upon wall construction and opening location, a
lintel (not included) may be required.
Outer case must extend into room at least ¾-inch beyond
inside wall to properly seat and attach air conditioner front
frame. If finished opening is framed by decorative molding
or other material, outer case must extend ¾-inch beyond
molding.
When wall thickness exceeds 14 inches, opening must be
modified to allow air to enter side louvers on case (see
special instructions on back ). Do not install air conditioner
in walls thicker than 17-inches.
20"
25
7
/
8
"
Electrical outlet must
be located within 5-feet
of this point.
Dimensions of Finished Opening
Masonry Construction
In masonry walls, cut or build a finished opening 20-inches
high by 25
7
/8-inches wide. Secure outer case in wall with
mortar or concrete nails driven through holes in sides of
outer case (predrill holes in case before securing).
Brick Veneer or Frame Wall Construction.
Cut or build rough opening large enough to allow a framed,
finished opening 20-inches high and 25
7
/8-inches wide.
Secure outer case to framing material with nails or screws
driven through holes in sides of outer case (predrill holes in
case before securing).
Framing
lumber
25
7
/
8
"
20"
Framed/Finished Opening
(brick veneer or frame wall construction)
Placement of Outer Case in Opening
Center outer case in finished opening. Front of case must
project ¾-inch (minimum) beyond inside wall in order to
attach air conditioner front frame.
If framing indoor side of finished opening with wood molding
(or other decorative material), outer case must extend
¾-inch (minimum) beyond molding in order to attach air
conditioner front frame.
Part No. 20086303 ©1998 Amana Appliances
Printed in USA Amana, IA 52204
Back of case (outdoor side) must be at least
3
/8-inch lower
than front of case to ensure proper condensate drainage.
Ensure case has proper slope before securing in place.
Caulk all
sides
Lintel and
flashing
(if required)
Outercase must project
a minimum ¾"
beyond inside wall
or molding to attach front frame
14¾"
Install case
with
3
/
8
"
slope to outside
for condensate
drainage
Front of outer case
to side air louvers
Optional
molding
(not provided)
Installed Case
(brick veneer or frame wall construction shown)
Installation in Wall Thicker Than 14 Inches
The side louvers in outer case provide ventilation to air
conditioner compressor and fan motor and must not be
blocked. When installing unit in a wall over 14-inches thick,
provisions must be made in wall opening to ensure free air
flow to the side louvers. This can be accomplished by
chamfering the vertical portions of the outside opening as
shown.
Ventilation louvers on top of case must not be obstructed.
Do not attempt to install unit in walls thicker than
17-inches.
Front of
outercase
4"
4"
Side air
louvers
(both sides)
¾" minimum
projection
17
3
/
16
"
14¾"
33
3
/
8
"
25
3
/
8
"
Chamfering Walls Thicker Than 14-inches
(top view)
  • Page 1 1