SCAN 5003 S FR User manual

Category
Stoves
Type
User manual

This manual is also suitable for

5003-S FR
/
FL
UK
SCAN
ASSEMBLY AND INSTRUCTION MANUAL SCAN 5003-S FR
/
FL
UK - ASSEMBLY AND INSTRUCTIONS MANUAL
SCAN
5003-S FR
/
FL
5003-S FR
/
FL
2
You have purchased a product by one of Europe’s leading manufacturers of wood-bur-
ning stoves, and we are sure that you will have years of pleasure from your purchase.
To make the best possible use of your stove, it is important that you follow our advice
and instructions. Read through this Assembly and Instruction Manual carefully before
you start to assemble your stove.
UK
SCAN
CONGRATULATIONS
ON YOUR NEW SCAN
BUILT-IN STOVE
SCAN 5003-S FR SCAN 5003-S FL
3
CONTENTS
¬¬
TECHNICAL DATA 4
Installation 4
Safety 4
Technical data and dimensions 5
Dimension sketch Scan 5003-S FR/FL 6
Type plate 7
Product registrationumber 7
¬¬
ASSEMBLY 8
Tools for the mounting of the built-in stove 8
Loose parts 8
Additional accessories 8
Disposal of packaging 8
Load-bearing foundation 8
Floor plate 9
Convection air 9
Existing chimney and pre-fabricated element chimney 10
Connection between built-in stove and steel chimney 10
Requirements for chimney 10
Balanced flue 10
Minimum distance to flammable materials 10
Building in the stove at a fire wall 10
Safety distance 10
Distance to flammable materials 11
Fresh air intake 12
Closed combustion system 12
Fresh air box for floor 12
Clips for Norway (Large rooms) 13
Heat-storage system 13
Mounting of the heat shields/convection covers 14
Before mounting of surrounding 18
Mounting of surrounding 19
¬¬
INSTRUCTIONS FOR USE 26
Baffle plates 26
Ash container 26
Combustion air 26
¬¬
INSTRUCTIONS FOR HEATING 27
Environmentally friendly operation 27
Lighting 27
Using the stove in various weather conditions 27
Continuous operation 28
Warning about over-firing 28
Firing in the spring or autumn 28
General notes 28
The function of the chimney 28
Chimney fire 28
¬¬
HANDLING OF THE FUEL 29
Selecting wood/fuel 29
Preparation 29
Storing 29
Moisture 29
Use of the following as fuel is illegal 29
Calorific value of the wood 29
¬¬
MAINTENANCE 30
Sweeping the chimney and cleaning the stove 30
Checking the stove 30
Servicing 30
Combustion chamber lining 30
Gaskets 31
Painted surfaces 31
Cleaning the glass 32
Disposal of stove parts 32
¬¬
TROUBLESHOOTING 33
¬¬
WARRANTY 34
4
YOU GET THE BEST USE OF
THE STOVE BY USING
A TOP-DOWN
LIGHTING METHOD
SEE
"INSTRUCTIONS FOR HEATING"
PLEASE NOTE!
TECHNICAL DATA
INSTALLATION
¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local
building regulations as well as the information provided in this Assembly and Instructions Manual.
¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition
you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning.
¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your Scan
dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
SAFETY
Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as
intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case
if parts that are necessary for the operation and safety of the stove are dismantled or removed.
5
TECHNICAL DATA AND DIMENSIONS
Test in compliance with EN 13240
CO Emission at 13% O
2
0,08
%
CO
Emission at 13% O
2
940
mg/Nm
3
Dust @ 13% O
2
11
mg/Nm
3
No
x
@ 13% O
2
118
mg/Nm
3
Efficiency
85
%
Energy efficiency index
114,3
Energy efficiency class
A+
Nominel output
5,7
kW
Chimney temperature EN 13240
206
°C
Temperature in flue conn. piece
246
°C
Amount of smoke
4,4
g/sek
Sub-pressure EN 13240
12
Pa
Recommended sub-pressure in
connecting piece
16-20 Pa
Required combustion air supply
10-25
m
3
/h
Fuel
Wood
Fuel consumption 2 kg/h
Amount of fuel required to light 2 kg
Amount of fuel, max. 2,5 kg
Materials
Silicate plate
Steel plate
Cast iron
Galvanised sheet
Chamotte
Surface treatment Senotherm
Max. log length 45 cm
Weight Scan 5003-S FR/FL 199 kg
Flue conn. piece internal diameter 132 mm
Flue conn. piece external diameter 149 mm
Approval type Intermittend*
* Intermittent operation in this context means normal use of
a built-in stove. In other words, you should let the fire die
down until only the embers are left before refuelling.
This built-in stove is produced in accordance with type
approval for the product, which also covers the product’s
Assembly and Instruction Manual.
The Declaration of Performance (DoP) is available from
www.scan.dk
B B
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003065.idw
95003065
Målskitse
17-06-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
1
8
0
0
7
5
4
4
6
4
5
8
2
6
0
0
2
1
2
,
5
3
0
7
,
5
370
692
3
9
0
1
2
5
4
A
B
C
6
DIMENSION SKETCH SCAN 5003-S FR/FL
All measures are in mm
*NB – remember to check the distance to flammable materials.
A
Height to the beginning of flue connecting piece at top outlet
B
Centre of fresh air intake - Inside measure: 103 mm, Outside measure: 120 mm
C
Flue conn. piece - Inside measure: 132 mm, Outside measure: 149 mm
SCAN 5003
- SCAN 5003
206A1X0032
2 / 109915
206A1X0032
7
Type plate Scan 5003-S FR/FL
Product registration number Scan 5003-S FR/FL
PRODUCT REGISTRATIONUMBER
All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of
this manual; you will always need to quote it when contacting your dealer or Scan A/S.
The product registration number is placed loose in the fireplace.
TYPE PLATE
All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials.
The eco energy label and type plate are placed in the box with steel parts and must replace the existing labels, which are located
in the built-in oven.
8
ASSEMBLY
TOOLS FOR THE MOUNTING OF THE BUILT-IN STOVE
¬ Spirit level ¬ Cordless electric drill
¬ Tape measure/foot rule ¬ Rubber hammer
LOOSE PARTS
The following loose parts are located in the built-in stove's combustion chamber:
¬ Oven mitt ¬ Flue connection piece
¬ Gasket for flue connecting piece ¬ Screws for fastening the flue connection piece
¬ Product registration number ¬ Combustion chamber lining
¬ Brackets for baffles plates
Extra parts for Scan 5003-S:
¬ Type plate ¬ Eco energy label
¬ Calcium Silicate Surround ¬ Steel base
¬ Glue cartridge ¬ 1 l. primer
¬ 10 Lamello P-14 - female ¬ 10 Lamello P-14 - male
¬ 10 Lamello P-14 pre-load clips ¬ 1 Tenso P-14 pre-load tool
¬ 4 Brackets ¬ 4 M5x10 screws
¬ 34 Metal pins ¬ 96 Screws Ø4x25/Ø8 (PAN TX20)
¬ 4 Adjustment screws ¬ 4 Steel bars
¬ 4 Washers Ø5 3/20x1,5 (HV140)
ADDITIONAL ACCESSORIES
¬ Floor plates (see page 9) ¬ Fresh air box (see page 12)
¬ Connection pipe Ø 100 mm ¬ Heat-storage stones (see page 13)
¬ Heat shields/convection covers (see page 14)
DISPOSAL OF PACKAGING
Your Scan built-in stove may come supplied with the following packaging:
Wood packaging
The wood packaging can be reused and after final use can be incinerated as a CO
2
neutral
product or sent for recycling.
Foam Send for recycling or waste disposal.
Plastic bags Send for recycling or waste disposal.
Stretch/plastic film Send for recycling or waste disposal.
LOAD-BEARING FOUNDATION
All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any
reinforcement of the beam structure. They can be positioned on ordinary beams/floor.
You should of course make sure that the foundation on which the stove is positioned can indeed support the weight of the stove
and, where applicable, a steel chimney, if you have opted for this solution. In case of doubt about the carrying capacity of the
floor, please consult a building expert.
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003222.idw
9500322217-06-2019
sr
Weight:
Area:
N/A N/A
1
8
M
i
n
m
m
Scan 5004-S FRL Scan 5003-S FL
Minimum frihøjde over gulvplader:
2
4
M
i
n
.
m
m
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003222.idw
9500322217-06-2019
sr
Weight:
Area:
N/A N/A
1
8
M
i
n
m
m
Scan 5004-S FRL Scan 5003-S FL
Minimum frihøjde over gulvplader:
2
4
M
i
n
.
m
m
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003070.idw
95003070
Gulvplader
20-08-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
10,10 kg
1349432 mm^2
202 352
8
2
0
1142
552 352
1
0
2
0
1492
9
FLOOR PLATE
If you are placing the stove on a flammable floor, you must comply with the national and local regulations on the size of any
non-flammable subsurface required to cover the floor around the stove.
Your local Scan dealer can advise you on regulations concerning protection of flammable materials in the vicinity of your stove.
The floor plate’s function is to protect the floor and flammable material against any sparks that may occur.
CONVECTION AIR
Convection means that there is an air circulation ensuring that the heat is equally
distributed in the room. It is important that the demands concerning convection
areas are observed.
¬ Min. area for ingoing convection air: 500 cm
2
¬ Min. area for outgoing convection air: 760 cm
2
If there is not enough convection air, the covering may be damaged.
Do not obstruct the convection holes.
Large shaped floor plate in clear or
smoke-coloured glass
Small floor plate in clear or
smoke-coloured glass
10
EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY
If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim-
ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
¬ When connecting a pre-fabricated element chimney, follow the manufacturer’s connection instructions for the
relevant chimney type.
CONNECTION BETWEEN BUILT-IN STOVE AND STEEL CHIMNEY
Your Scan dealer, or local chimney sweep, can advise you on choosing a make and type of steel chimney. This ensures that the
chimney will match your wood-burning stove.
REQUIREMENTS FOR CHIMNEY
The chimney must have a minimum internal diameter of 148 mm and have a T400 designation, with G for the soot fire test. The
length must be min. 5 metres.
If you opt to connect the built-in stove with an elbow pipe, you should use a curved elbow, as this gives a better draught.
If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the
horizontal part can be cleaned through here.
The requirements to the chimney and the flue pipe in terms of safety distances must be met.
¬ Choosing the wrong length or diameter of steel chimney could impair functionality
¬ Always comply exactly with the instructions provided by the steel chimney supplier
BALANCED FLUE
If the stove is connected with a balanced flue, we recommend the use of a 100 mm Lindab tube and a chimney length of min. 5 m.
MINIMUM DISTANCE TO FLAMMABLE MATERIALS
Distance to back: 0 mm - glass: 800 mm. - ceiling: 580 mm.
You should however assess whether furniture or other items might become excessively dry due to being too close to the stove.
BUILDING IN THE STOVE AT A FIRE WALL
We refer to the building sketches on page 11.
SAFETY DISTANCE
European, national and local regulations concerning safety distances for wood-burning stoves and flue pipes must be complied
with.
(WHICH IS NOT PROTECTED BY FIREWALL)
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1005\91005029.idw
91005029
Uisoleret røgrør
23-01-2019
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
1
7
5
1
0
0
75
15
450
200
1
5
0
0
8
0
0
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003064.idw
95003064
Opstillingsafstand
12-02-2020
KEN
Scan 5003-S
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
5
8
0
250
138,7
288,3
4
0
0
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003064.idw
95003064
Opstillingsafstand
12-02-2020
KEN
Scan 5003-S
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
5
8
0
250
138,7
288,3
4
0
0
11
Floor
Ceiling
Flammable material
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick
or other material with corresponding fireproof and
insulating abilities
All distances are in mm.
All distances are minimum distances
Distance to furniture: 800 mm. from glass
* Distance to flammable material
Insulated length
DISTANCE TO FLAMMABLE MATERIALS
These distances apply for an insulated flue pipe all the way down to the stove.
, WITH INSULATED FLUE PIPE
WARNING!
Keep the convection air
intakes free from blokage
F
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003037.idw
95003037
Friskluftsadapter
04-02-2019
ken
Scan 5003 FR/FL
Weight:
Area:
N/A N/A
66
1
2
1
12
FRESH AIR INTAKE
In a well-insulated house the air used for the combustion process has to be replaced. This particularly applies to houses with
mechanical ventilation. There are different ways of making sure that air is exchanged. The most important thing is to ensure
that there is a supply of air to the room where the built-in stove is located. The external wall vent must be located as close to the
stove as possible, and you must be able to close it when you are not using the stove.
National and local building regulations must be followed with regard to connection of a fresh air intake.
The diameter of the connection piece for fresh air is 120 mm. If you want to use a 100 mm connection tube you can mount a
gasket on the outside of the tube before mounting the tube inside the connection piece.
CLOSED COMBUSTION SYSTEM
You should use the closed combustion system for the built-in stove if you live in a newly-built, airtight home. External
combustion air is connected through a ventilation pipe via the wall or floor.
We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, which can
be closed when the oven is not in use. It can also be an advantage to insulate the ventilation pipe.
Minimum
Ø 100 mm ventilation pipe, maximum length: 6 metres with a maximum of one bend. We recommend smooth steel pipes.
NOTE: If the stove has a fresh air connexion or closed combustion, the ventilation pipe must be open, when the stove is in use!
FRESH AIR BOX FOR FLOOR
A fresh air box and connection pipe (Ø 100 mm) are available as accessories.
(ACCESSORY)
C ( 1 : 2 )
C
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003019.idw
95003019
Spjæld clips til Norge, large rums
13-07-2017
sr
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
C ( 1 : 2 )
C
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003019.idw
95003019
Spjæld clips til Norge, large rums
13-07-2017
sr
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
70 kg
13
Mount the clips
CLIPS FOR NORWAY (LARGE ROOMS)
NB: Norway only!
HEAT-STORAGE SYSTEM
Heat-storage stones are made from a special material with a high heat capacity. The stones are heated when the stove is on,
re-releasing heat once it is off. This extends the time over which the stove remains warm.
(ACCESSORY)
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003009.idw
95003009
Montage af varmeskjold
11-07-17
SR
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003009.idw
95003009
Montage af varmeskjold
11-07-17
SR
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
3
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5002\95002007.idw
95002007
Montage at varmeskjold
20-06-2017
sr
Scan 5002
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
B ( 0,40 : 1 )
B
Stove:
Path:
Material:
Date:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5002\95002014.iam
95002014
Montage af varmeskjold
22-06-2017
sr
Scan 5002
Weight:
Area:
N/A N/A
Articlenumber:
Constructed /Changed by:
B ( 0,40 : 1 )
B
Stove:
Path:
Material:
Date:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5002\95002014.iam
95002014
Montage af varmeskjold
22-06-2017
sr
Scan 5002
Weight:
Area:
N/A N/A
Articlenumber:
Constructed /Changed by:
1
2
14
MOUNTING OF THE HEAT SHIELDS/CONVECTION COVERS (ACCESSORY)
Place the heat shield on top
of the built-in stove
Place the heat shield at the
top on a flat surface with
the bottom upwards
Put the 2 units together
and attach them by bending
slightly the splits with an
adjustable spanner
B ( 1 : 2 )
B
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003011.idw
95003011
Montage af varmeskjold
11-07-17
SR
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
B ( 1 : 2 )
B
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003011.idw
95003011
Montage af varmeskjold
11-07-17
SR
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
A ( 1 : 2 )
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003010.idw
95003010
Montage af varmeskjold
11-07-17
SR
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
A ( 1 : 2 )
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003010.idw
95003010
Montage af varmeskjold
11-07-17
SR
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
4
5
A ( 1 : 2 )
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003010.idw
95003010
Montage af varmeskjold
11-07-17
SR
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
B ( 1 : 2 )
B
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003011.idw
95003011
Montage af varmeskjold
11-07-17
SR
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
15
MOUNTING OF THE HEAT SHIELDS/CONVECTION COVERS
(ACCESSORY)
Mount the strings on both
heat shields
First mount the lateral heat
shields on the stove and
then the rear heat shield
D ( 1 : 4 )
D
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003013.idw
95003013
Montage at varmeskjold
12-07-17
sr
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
C ( 1 : 4 )
C
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003012.idw
95003012
Montage at varmeskjold
12-07-17
sr
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
6
B ( 1 : 4 )
B
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5002\95002012.idw
95002012
Montage at varmeskjold
22-06-2017
sr
Scan 5002
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
16
MOUNTING OF THE HEAT SHIELDS/CONVECTION COVERS
(ACCESSORY)
Fasten the heat shields
(sides and rear) by bending
slightly the splits with an
adjustable spanner
E ( 1 : 4 )
E
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003015.idw
95003015
Montage at varmeskjold
12-07-17
sr
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
E ( 1 : 4 )
E
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003016.idw
95003016
Montage at varmeskjold
12-07-17
sr
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
5
4
7
E ( 1 : 4 )
E
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003015.idw
95003015
Montage at varmeskjold
12-07-17
sr
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
E ( 1 : 4 )
E
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003016.idw
95003016
Montage at varmeskjold
12-07-17
sr
Scan 5003
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
5
4
mm
17
MOUNTING OF THE HEAT SHIELDS/CONVECTION COVERS
(ACCESSORY)
IMPORTANT: Open the four valves in the top
with a flat-head screwdriver. The opening
should be approx. 55 mm
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003057B.idw
95003057B
Montage af omramning
08-08-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
18
BEFORE MOUNTING OF SURROUNDING
Remember to cut out the hole for top outlet, rear outlet, or fresh air before placing the stove in the framing material!
E
F
F
G
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003067.idw
95003067
Tenso P 14 klips
04-07-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
1
3
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003066.idw
95003066
Preload Tenso P 14 værktøj
04-07-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
E
F
F
G
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003067.idw
95003067
Tenso P 14 klips
04-07-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003066.idw
95003066
Preload Tenso P 14 værktøj
04-07-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
Tenso P14
2
Tenso P 14
Pre-load Clip
E
F
F
G
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003067.idw
95003067
Tenso P 14 klips
04-07-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
4
E
F
F
G
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003067.idw
95003067
Tenso P 14 klips
04-07-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
5
B
C
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5004\95004203.idw
95004203
Metaldyvel
05-07-2019
KEN
Scan 5004-S FRL
Weight:
Area:
N/A N/A
6
B
B
C
C
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003069.idw
95003069
Samling af plader med Tenso P-14
05-07-2019
KEN
Scan 5003-S FR/FL
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
B
B
C
C
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5003\95003069.idw
95003069
Samling af plader med Tenso P-14
05-07-2019
KEN
Scan 5003-S FR/FL
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
B
C
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5004\95004203.idw
95004203
Metaldyvel
05-07-2019
KEN
Scan 5004-S FRL
Weight:
Area:
N/A N/A
H
H
J
J
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003068.idw
95003068
Tenso P 14 klips
04-07-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
H
H
J
J
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003068.idw
95003068
Tenso P 14 klips
04-07-2019
KEN
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
19
FOLLOW THE MOUNTING INSTRUCTIONS CAREFULLY!
MOUNTING OF SURROUNDING
Important! All contact areas between the plates must be cleaned with a dry cloth and primed
before applying the glue in a very thin layer
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003062.idw
95003062
Montage af omramning
30-04-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003061.idw
95003061
Montage af omramning
30-04-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
3
0
K
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003063.idw
95003063
Montage af omramning
30-04-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
1
32
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003042.idw
95003042
Montage af omramning
30-04-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
2
9
8
2
7
8
,
5
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003042.idw
95003042
Montage af omramning
30-04-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
2
9
8
2
7
8
,
5
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003061.idw
95003061
Montage af omramning
30-04-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
3
0
K
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003063.idw
95003063
Montage af omramning
30-04-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
G
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003062.idw
95003062
Montage af omramning
30-04-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
K
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 5003\95003063.idw
95003063
Montage af omramning
30-04-2019
ken
Scan 5003-S FR/FL
Weight:
Area:
N/A N/A
20
MOUNTING OF SURROUNDING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

SCAN 5003 S FR User manual

Category
Stoves
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI