Accura ACC5008 Athena Operating instructions

Category
Postal scales
Type
Operating instructions
ACC5008 Athena Electronic Kitchen Scale
Operating Manual
Thank you for choosing the Accura Athena electronic kitchen scale. To ensure proper
operation and to maintain the lifespan and the utmost accuracy of the scale, please read
these instructions carefully before use.
1. Key features
Capacity 10kg/10000ml/11lbs/352 fl oz
Graduation 1g/1ml/0.1oz/0.1fl oz
Real time clock display
Can hang on the wall or stand on a benchtop
Liquid measurement for water and milk
Tare function
2 x 1.5V AAA batteries included
Low battery power / overload indication
2. Operation instructions
Open the battery door at the back of the scale, and remove the plastic isolators on
the batteries.
Effective weighing area
LCD display area
Battery case cover
Kickstand
Unit conversion button
Screen display
Key illustration
To switch on & to set time
1. Install battery and enter time setting mode automatically.
When hour display is flashing, touch to set
hour. Please mind AM/PM selection during setting.
2. Press to confirm and prompt to minute setting. When
minute display is flashing, touch to set minute.
3. Press to finish time setting and enter weighing mode.
To re-set time
Under real time display mode, press for 3 seconds to enter time setting mode.
Set hour first, then minute. Touch to adjust time and for
confirmation. (Touch & Hold will speed up the advance of value)
Remark: In time setting process, return to real time display automatically after idling for 60 seconds.
Zero
AM/PM
Tare
Negative Value
Mode
Water volume mode
Weight mode
Milk volume mode
Setting / Zero / Tare / Up
Unit conversion (at the bottom of
product, under kickstand)
Press for 3 seconds
Press
Press to confirm
Touch to adjust hour
Touch to adjust minute
To start weighing
Weighing mode
A. Place the scale on a solid and flat surface.
B. Gently touch by hand to wait until LCD shows “0”.
C. If LCD shows weighing mode, please enter to Step D directly.
If LCD shows volume mode, please Touch & Hold to convert to
weighing mode, and then enter Step D.
D. Load weighing object on scale (or bowl) to start weighing, LCD will show the
weighing reading.
E. Place bowl (if used) on the scale and tare the reading before weighing.
(Tare function described additionally)
Touch
to switch on
Touch & Hold
to change unit
mode
Touch
to switch on
2. Volume indication mode
A. Place the scale on a solid and flat surface
B. Gently touch by hand to wait until LCD
shows “0”
C. Touch & Hold to convert to Water or
Milk mode.
(Refers to mode setting specifically)
D. Put a liquid container onto the scale platform, LCD
shows the weight of container
E. Touch to reset “0” and tare.
F. Pour liquid (water or milk into the container, LCD
shows the volume of the liquid.
G. Touch & Hold to convert to weighing
mode, and check the weight of liquid.
Unit & mode setting
If the scale is with both measuring systems of Metric (g,kg) and Imperial (oz, lb),
you can press ”unit” convert between two systems during the course of weighing:
1. Press shortly to convert weight unit between Metric and Imperial systems.
Press shortly
Touch
to switch on
Touch & Hold
Change unit mode
Put on a liquid
container
Touch
Touch
to switch on
Pour in liquid
2. Touch & Hold for 3 seconds to enter mode setting and convert between
weighing mode and volume mode (water or milk).
Metric system:
Imperial system:
Remark: The unit system of scale depends on sales destination or the requirement
of distributor.
Zero or tare function
To weigh different loads consecutively without removing loads from the scale. Put
first load on the scale get weight reading. Touch button to reset the
LCD reading to “0” before adding next load. You can repeat this operation.
Condition 1: “ZERO” function
When total sum of all loads on scale ≤ 4%
LCD will show “-----“ or “0g” each time
is touch.
-----“ means not stable, please wait for a moment.
“0g” and meanwhile an icon “ ” on upper left
corner of LCD mean “ZERO” function is active.
Max. Weight capacity remains unchanged.
Touch & Hold
Touch & Hold
Touch & Hold
Touch & Hold
Touch & Hold
Touch & Hold
Touch & Hold
Touch & Hold
Touch
Condition 2: “TARE” function
When total sum of all loads on scale > 4%
LCD will show -----“ or “0g” each time
is touch.
-----“ means not stable, please wait for a moment.
“0g” and meanwhile an icon “ ” on upper left
corner of LCD mean “TARE” function is active.
Max. Weight capacity reduced by total weight of all
loads.
To convert between weighing mode & real time display mode
3. Care
If the screen reads “Lo” the scale will turn off after a few seconds and please replace
the battery.
If the screen reads “Err”, the scale is overloaded. Remove the last item.
Wipe the surface of the scale with a damp cloth and dry before and after each use.
Do not immerse in water and do not use any detergents
Do not leave the scale in a damp or steamy environment
The scale is for domestic use only and is not legal for trade.
If the scale is not being used for a long period, please remove the battery.
CONTACT
Albi Imports
87 Chifley Drive, Preston, Victoria 3072
E: [email protected] P: +61 (03) 9474 1300
Touch
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Accura ACC5008 Athena Operating instructions

Category
Postal scales
Type
Operating instructions

Ask a question and I''ll find the answer in the document