CAMPLUX ENJOY OUTDOOR LIFE CM264B-N1 User manual

Type
User manual

This manual is also suitable for

GAS WATER HEATER
RESIDENTIAL INDOOR TANKLESS GAS
WATER HEATER
USE & CARE MANUAL
WITH INSTALLATION INSTRUCTIONS FOR THE INSTALLER
Display screen
Front cover
Motor fan
Temperature
controller
Heat exchanger
Fixing board
Burner assemblu
Ignition pin
Flame sensor
Flame
sensor board
Back cover
Computer board
Wind switch
Hot water
temp. sensor
REPLACEMENT PARTS AND DRAWING
Code
Code meaning Code
explanation
E0 Power
failure protection The
water
control
switch
has
been
shut off before the
circle
connect
to
the
power,
the
water
heater cant be
started.
E1 Residual
fire protection Detect
the
flame
as
soon
as
connect
the power, the
controller cant be started.
E2 Valve failure protection When
the
gas
valve
is
blocked,
the controller is
protected.
E3 Gas
line problem
or
no
ignition
pulse
The ignition was unsuccessful, or an accidental flameout
occurred.
E4 Temperature sensor error Temperature sensor has
problem
E5 Overheating protection Water
heater
automatically
shuts
off when water
temperature is above 191
º
E6 Air
flow
pressure
switch
protection
The
fan
is
broken
or
the
flow
pipe
has
problem to make
the switch cant open normally.
E7 Air flow pressure short circuit
protection
The switch is short circuit when starting the water
heater.
F
35
CAMPLUX
TA NKLESS
Time/Temperature Relationship in Scalds
Water
Temperature Time
To Produce a Serious Burn
120
49
More
than 5 minutes
122
1
1/2
2 minutes
130 54 About 30 seconds
135 57 About 10 seconds
140 60 Less than 5 seconds
145
63
Less than 3 seconds
150 66 About 1 1/2 senconds
155 68 About 1 second
Table courtesy of Shriners Burn Institute
22
50
50
to
3
Cap
Sediment Trap
Wall Thimble
Vent Termination
LED
Display
Union
To Hot Water
Faucet(s)
Drain Valve
To Suitable
Cold Water Supply
Shut-Off Valve
Service
Valve
Union
Relief
Valve
Manual Gas
Shut-Off Valve
(Supplied)
33
26
Hot Water Tap
Air Relief Vavle
Drain Vavle
12
1/ 4" per foot downward slope
6 clearance
12in
minimun
Vent
Adapter
Support
Hanger
9.8"
9.8"
Typical Horizontal Termination
W/1/4"per foot DOWNWARD Slope
To Drain,Dispose of condensate
in accordance to local codes
CORD
.
25
1/4" per foot downward slope
6 clearance
12in
minimun
Vent
Adapter
Support
Hanger
9.8"
9.8"
Typical Horizontal
Termination W1/4"
per foot DOWNWARD Slope
Installing the water heater,Continued......
Inner Thimble
Section
Outer Thimble
Section
Side View
CAUTION: Follow the vent manufacturers
installation instructions as design might
vary from manufacturer to manufacturer.
WARNING: Use UL approved Category III
vent material only. No other vent material
is permitted. Owner must refer to vent
manufacturers instructions and specifcations.
23
not proper
more than 10.5"w.c(2.61kPa).
DANGER:
To Hot Water
Faucet(s)
Power
supply
CORD
Union
Union
Relief
Valve
Drain Valve
Service
Valve
To Suitable
*Note:A fexible drain tube can be used
-o
3300
3300
Manual Gas
Shut-Off Valve
(Supplied)
Cap
Cold Water Supply
Shut-Off Valve
Sediment Trap
Manual Gas
Supply Line
Shut-Off Valve
Foil
Tapping Screw
Vent Terminnation
16
Vent Seam
More Than 6"
1/4" Per Foot
Downward Slope
FOR NON-DIRECT VENT INSTALLATIONS IN THE US AND CANADA
21
1/4" Per Foot
Downward Slope
Insulation
Material
Insulation
Material
Inspection
Hole#1
Inspection
Hole#2
Ceiling
Board
*Reference Vent Manufacture
Component Information-Page17
Number of 90"
elbows(bends)
Maximum
length
of
sstraight pipe
1 32'
2 27'
3 22'
One(1)90° elbow
is equivalent
to 5
feet of
sraight pipe
23
8
for
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

CAMPLUX ENJOY OUTDOOR LIFE CM264B-N1 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI