TROUBLESHOOTING GUIDE
• Filtercordmustbepluggedintoa3wire
outlet that is protected by a Class A
GroundFaultCircuitInterrupter.
• Resetcircuitbreaker.Ifcircuitbreakertrips
repeatedly, your electrical system may
have a defect. Turn off circuit breaker and
call an electrician to correct the problem.
• Letmotorcooldown.
• AdjustthechlorineandpHlevel.Consult
your local swimming pool supply stores.
• Cleanorreplacecartridge.
• Checkthecartridgeforholes.Replaceif
damaged.
• Operatethefilterforlongerperiods.
• Cleanthestrainerscreenattheinlet.
• Clearanyobstructionsintheintakehoseby
discharging it inside pool wall.
• Tightenhosenuts,checkhosesfordamage,
check pool water level.
• Cleancartridgemoreoften.
• Cleaninsidetheplungervalve.
• Pullvalvehandletofulluprightposition.
• Installthenozzleattheupperpositionofthepool
inlet, and the strainer at the lower position of the
pool outlet.
• Makesuretheinletthreadedairconnectoris
connected to the pool inlet upper hole.
•Fillpooltocorrectwaterlevel.
• Cleanstrainerscreensatpoolinlet.
• Tightenhosenuts,checkhosefordamage.
• Clearanysticksorleavesintheintakehose.
• Turnandpullvalvehandletofulluprightposition.
• Removecover&checkforO-ring.
• Tightencoverorvalve(Manually).
• Tightenorreinstallhosenut.
• Puttheo-ringbackintothegroove.
• Replace a new hose.
• Openairreleasevalve,waituntilwaterstarts
to flow out of the air release valve, close air
release valve.
• Thelowerpositionofpooloutletconnectstofilter
pump water inlet. The upper position of pool inlet
connects to filter pump water outlet.
• Tightenorreinstallplungervalve.
• Tightenairjetvalveandmakesureit’s
facing up.
• TurnpumpONandrunforfewseconds,then
turnOFF,repeat3times.
• Removeairjetvalve,flushdirtoutwithwaterand
replace valve back.
• Replaceanewairjetvalve.
FILTERMOTOR
FAILSTOSTART
FILTERDOESN’T
CLEANPOOL
FILTERDOESN’T
PUMPWATEROR
THEWATERFLOW
ISVERYSLOW
PUMPDOESN’T
WORK
TOPCOVER
LEAKING
HOSELEAKING
AIRLOCK
INLETTREADED
AIRCONNECTOR
/AIRJETVALVE
LEAKING
• Themotorisnotpluggedin.
• TheGFCIcircuitbreakeris
tripped.
• Motortoohotandoverload
protection shut motor off.
• ImproperchlorineorpH
levels.
• Filtercartridgeisdirty.
• Damagedcartridge.
• Excessivelydirtypool.
• Thestrainerscreenis
restricting the water flow.
• Cloggedinletordischarge.
• Anairleakontheintakeline.
• Scaleorbuilduponcartridge.
• Excessivelydirtypool.
• Dirtyfiltercartridge.
• Thenozzleandstrainer
connection are reversed.
• Inletthreadedairconnector
connected to the wrong hole on
the liner.
• Lowwaterlevel.
• Strainerscreenpluggedup.
• Anairleakontheintakehose.
• Faultymotorortheimpelleris
jammed.
• Anairlockinsidethecartridge
chamber.
• O-ringmissing.
• Coverorairreleasevalvearenot
tight.
• Hosenutsarenotwell-fitted.
• Hoseo-ringdislodgedwhen
connecting the hose.
• Hosebroken.
•There’sairtrappedinthe
pump housing and inlet hose.
•Theinletandoutlethoses
connection are reversed.
• Plungervalvenotwell-fitted.
• Airjetvalveisnottightand
facing up.
• Airjetvalveinternalsealblocked.
• Airjetvalveinternalsealdirty.
• Airjetvalvebroken.
TROUBLE CAUSE SOLUTION