Groen HY-6SG Datasheet

  • Hello! I am an AI chatbot trained to assist you with the Groen HY-6SG Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Applications
Pasta
Rice
Vegetables (Fresh & Frozen)
Seafood (Fresh & Frozen)
Poultry
Potatoes
Eggs
Meats
Reheat Cook-Chill &
Prepared Foods
6-Pan Capacity
Stainless Steel
Pressureless Steamer/
Kettle Combination
With Gas
Pressure Boiler in
Cabinet Base
Short Form
Unit shall be a Groen HyPLUS™
pressureless steamer Model
HY-6SG w/TDC/3-20, with 20
quart tilting kettle powered
by electric pressure boiler
mounted in 36” wide cabinet
base, per bulletin 78Bb. All
stainless steel construction
with two independent steamer
chambers, each with powerful
blower to circulate steam
within cavity and individual
60 minute timer with constant
steam setting. Steamer doors
are insulated, field reversible,
with easy open latch and
hidden magnetic door switch.
Drip sink with condensate
drain is provided under cavity
doors. Three (21/2” deep)
pan capacity per chamber.
Cabinet base has stainless
steel frame, all stainless steel
exterior, with removable front
access doors and adjustable
bullet feet. Pouring sink and
HOT/COLD water faucet
provided for kettle. Boiler
ASME code constructed for 15
PSI maximum with 200,000
BTU firing rate, 120,000
BTU output and 3.7 boiler
horsepower. Power take-off
to divert steam to adjacent
equipment is standard. AGA
Design certified and standard
with automatic boiler drain
and electronic ignition. See
other side for water, drain, and
electric connections required.
Made in USA.
Pan Size Per Cavity Total
12 x 20 x 1 6 12
12 x 20 x 2 1/2 3 6
12 x 20 x 4 2 4
Groen HyPerSteam, Page 15
160180B
Revised 08/09
HyPerSteam Pressureless Steamer
model HY-6SG w/TDC/3-20
Description
Steamer shall be a Groen HyPLUS™ Model HY-6SGw/
TDC/3-20, stainless steel twin cavity, 6 pan pressureless
steamer, with 20 quart tilting steam jacketed kettle, and
cabinet mounted 200,000 BTU gas steam boiler, per
Bulletin 78Bb and as follows:
Construction
Steamer cavities and cabinet base shall be all stainless
steel construction. Steamer unit shall have a unitized
body with removable right side panel providing access
to internal component. Steamer doors are all stainless
steel with strong continuous hinge, are field reversible
and provided with a one piece, replaceable seal. Hidden
magnetic door switch cuts power to blower and steam
flow to that cavity, when the door is opened. Pan support
racks shall be polished stainless steel and removable for
easy cleaning. Wide drip sink with condensate drain is
positioned under cavity doors.
Kettle shall have one piece welded construction of Type
304 stainless steel, with reinforced rim and butterfly
shaped pouring lip. Kettle support legs shall be heavy
tubular stainless steel. Flush mounted pouring sink with
splash shield standard.
36 wide cabinet base shall have stainless steel frame
with all stainless steel top deck, removable front access
doors, with side and rear panels standard. Front and rear
legs shall have adjustable bullet feet. Flanged feet are an
available option.
Finish
Cabinet exterior, including door, shall be finished to a #3
uniform finish. Cavity interiors are electro polished stain-
less steel. Kettle exterior shall be polished to a bright high
buff finish.
ASME Code & UL Approval
Cabinet mounted boiler shall be ASME Code constructed
and National Board Registered for operation up to 15 PSI.
Kettle shall be coded and registered for operation up to
55 PSI. Kettle shall be coded and registered for opera-
tion up to 55 PSI. Gas boiler shall be designed certified
by the American Gas Association and Steamer unit shall
be U.L. listed.
Sanitation
Unit shall be designed and manufactured to meet NSF
known health department and sanitation codes and be
NSF listed.
Controls
Steamer cavity controls shall be mounted on the front
panel for easy replacement or repair and will include a
separate ON-OFF/60 minute timer control with constant
steam setting, for each cavity. Kettle steam control valve
and HOT/COLD water faucet handles will be front mount-
ed with boiler controls. Gas boiler shall be provided with
a gas control valve, power-ON switch, RESET light, start
switch, low water sensor, pop safety valve, water level
sight glass and outside cabinet mounted pressure gauge.
Performance Features
Unit will shut off if water level is low or unit builds too
much pressure. When power switch is turned “off, the
boiler automatically drains to reduce sediment build-up,
after water has cooled to 170ºF.
Each steamer cavity shall have a powerful side mounted
blower, which increases steam velocity and provides effi-
cient steam distribution throughout cavity and between
loaded pans.
Cabinet Base Steam Source
Unit shall have twin electric-heated, cabinet-mounted pres-
sure boiler to provide atmospheric steam to each chamber
at a temperature of approximately 21F and steam to
kettle at approximately 10 PSI. The 200,000 BTU generator
delivers 3.7 boiler horsepower. Unit come standard with
electronic ignition.
Hot & Cold Water Faucet
Unit shall be provided with hot and cold water faucet with
swing spout standard.
Pan Capacity
Options/Accessories
Flanged mounting feet
Independent cold water to condensate spray
Cover and-or basket insert for kettle
Installation
Unit requires gas service via 1/2 NPT pipe. Unit requires
1/2 NPT cold water supply line and 3/8” NPT hot water
supply line for faucet; 1 1/4” NPT free venting drain; and
115 volt, single phase, 60 cycle 15 AMP electric service,
4 AMP maximum load. Steam source for adjacent equip-
ment: see SE model.
Water Supply Requirements
All water boiler systems are subject to contamination and
failure due to mineral content found in most water supplies.
To minimize service problems, a water treatment (soften-
ing) system is recommended when water quality is found to
exceed limits stated on other side and operator manual.
Origin of Manufacture
Steamer/Kettle Combination shall be designed and manu-
factured in the United States.
1055 Mendell Davis Drive, Jackson, MS 39272
888-994-7636, unifiedbrands.net
Please reference our website for the most
updated product information and specifications.
DRAIN CONNECTION: 1-1/4"(31) NPT
(INCLUDES AUTOMATIC & MANUAL BOILER, STEAMERS, CONDENSATE SPRAY, KETTLE & SINK)
COLD WATER SUPPLY: 1/2"(31) NPT (FOR BOILER, CONDENSATE SPRAY & FAUCET)
OPTION: SEPARATE CONDENSATE SPRAY 3/8"(9) NPT (ADD KIT #MS102210)
ELECTRICAL CONNECTION: 7/8"(22) DIA. HOLE (REF. 1/2"(13) CONDUIT KNOCK-OUT)
GAS CONNECTION: 1/2"(13) NPT
STEAM POWER TAKE-OFF: 1/2"(13) NPT
1. MINIMUM CLEARANCE FROM COMBUSTIBLE MATERIALS
RIGHT SIDE 2" (51)
LEFT SIDE 4" (102)
REAR 6" (152)
1
SERVICE CONNECTIONS:
NOTES:
2
5
6
7
5" W.C. (MIN.)
NATURAL
14" W.C. (MAX.)
11" W.C. (MIN.) 14" W.C. (MAX.)
PROPANE
INCOMING GAS PRESSURE
*
INCHES WATER COLUMN
*
RECOMMENDED
3.5" W.C.
OPERATING
GAS PRESSURE
10.0" W.C.
*
INPUT RATE (BTU/HR.): 200,000
OUTPUT RATE (BTU/HR.): 120,000
BOILER HORSEPOWER: 3.7
3
4
HOT WATER SUPPLY: 3/8"(9) NPT (FOR FAUCET)
2. DIMENSIONS IN BRACKETS ( ) ARE MILLIMETERS.
26
1
1
2
(38) MIN.
(67) MAX.
8
5
2
9
16
57
(1453)
3
16
(675)
4
5
8
(117)
36
1
8
(918)
34
3
16
(868)
4
6
(152)
(102)
2
1
3
(51)
6
7
8
(98)
23
3
1
16
(586)
24
16
5
(618)
7
1
7
2
21
9
16
1
4
3
4
18
1
2
(192)
(470)
(540)
14
3
8
(365)
3
(76)
2
30
5
8
(778)
2
1
(64)
ADJUSTABLE
CONDENSATE
DRAIN VENT
FLUE
CLEARANCE
6
5
1
4
(159)
20
8
3
(518)
BULLET FEET
5
5
18
1
16
(459)
2
4
7
6
4
(102)
SINK
DRAIN
SEE NOTE 1
SEE NOTE 1
CLEARANCE CLEARANCE
SEE NOTE 1
(IF SECOND CONNECTION ORDERED)
(OPTIONAL)
OF WATER CONNECTIONS
UN-TREATED
DETAIL VIEW
WATER
SUPPLY
CONN.
CONN.
SUPPLY
WATER
TREATED
121506 REV. C
P/N 121506 REV C
Model HY-6SG w/TDC/3-20
1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net
© 2009 Unified Brands. All Rights Reserved. DOVER® and the DOVER® Logo are registered
trademarks in the United States [and various other countries] of Unified Brands, a
wholly-owned subsidiary of Dover Corporation.
/