  • Hello! I am an AI chatbot trained to assist you with the Trojan TrojanUVMax G+ Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Date of installation: ______________________
Installed by: ______________________
Installer phone#: ______________________
Serial #: ______________________
(Found on label on side of Power Supply)
A5-micron(nominal)sedimentfiltermustbeinstalledupstreamof
(before)anyUVsystem
Thisproductisforindooruseonly.Keepallcomponentscleananddry.
Cleanthequartzsleeveregularlyforoptimumperformance
KEYINFORMATIONYOUSHOULDKNOW:
Congratulations.Bypurchasingthissystem,youhave
takenthefirststepinensuringsafedrinkingwater.
DesignedusingthemostadvancedUVtechnology
availabletoday,yourUVsystemisdesignedtoprovide
youwithyearsoftroublefreeoperationwithminimal
maintenancerequired.
Trojan Technologies
3020GoreRoad,London,Ontario,CanadaN5V4T7
www.trojanuv.com[email protected]1-800-265-5774
Ultraviolet Water Purification System
Owners Manual
NSF information pertains to
TrojanUVMax
TM
Pro Series models.
Systemtestedandcertified
byNSFInternational
againstNSF/ANSI
Standard55fordisinfection
performance,ClassA.
ProSeries(Pro10,Pro20&Pro30)
PlusSeries(G+,H+,J+)
BasicSeries(G,H,J)
WARNING–
Toguardagainstinjury,basicsafetyprecautionsshouldbeobserved,includingthefollowing:
READANDFOLLOWALLSAFETYINSTRUCTIONS.
DANGER–Toavoidpossibleelectricshock,specialcareshouldbetakensincewaterisemployedintheuseofthissystem.Unlessa
situationisencounteredthatisexplicitlyaddressedbytheprovidedmaintenanceandtroubleshootingsections,donotattemptrepairs
yourself;refertoanauthorizedservicefacility.
CAUTION-Donotoperatewithbrokenorfaultypartsasthismayresultinexposuretoultravioletradiation.Contactsupplierforreplacement
parts.
Donotoperatethesystemifithasadamagedcordorplug,orifitismalfunctioningorifithasbeendroppedordamagedinanymanner.
Alwaysunplugthesystem,shutoffwaterflowandreleasewaterpressurebeforeservicingorcleaning.Neveryankcordtoremovefrom
outlet;graspthewallplugandpulltodisconnect.
Donotusethesystemforotherthanintendeduse.Theuseofattachmentsnotrecommendedorsoldbythemanufacturermaycausean
unsafecondition.
Topreventriskofelectricalshock,connectthissystemonlytoaproperlygrounded,grounding-typepowersupplyreceptaclethatis
protectedbyaGroundFaultCircuitInterrupter(GFCI).InspectperformanceofGFCIaspermanufacturer’ssuggestedmaintenance
schedule.Ifanextensioncordisused,ensureitisofasufficientratingandacceptstheplugfromthissystem;neveruseanadapter.
Visuallyinspectthissystempriortoinstallation.Ifthequartzsleeveorlampisbroken,crackedordamagedinanyway,donotuse.Contact
thesupplierforreplacementparts.
Keepallconnectionsdryandofftheground.Donottouchplugwithwethands.
Thelightemittedbythelampwillcauseseriouseyedamageandburnunprotectedskin.Donotplugsystemintoanelectricaloutletwithout
firstproperlysecuringthelampintothechamber.Unplugthesystempriortoremovingthelampfromthechamber.
IftheUVsystemmalfunctionsorfails,watermustbeboiledpriortoconsumptionuntiltheUVsystemisoperationalandthewaterlineshave
beenshocked.Systemfailureisindicatedbythesystem’saudibleandvisualalarmsortheabsenceofanyindicatorlight.
Intendedforindooruseonly.Systemmustnotbeexposedtoweatherelements.Inseasonalapplications,chambermustbedrainedto
preventfreezing.
Installationofthissystemmustbeinaccordancewithlocalplumbingandelectricalcodesaswellasanyandallapplicableregulationsand
laws.
SAVETHESEINSTRUCTIONS.
Note:maximumpressureratingis100PSI(6.89bar)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
SAFETY INSTRUCTIONS
GROUNDING
Thisproductmustbegrounded.Ifitshouldmalfunctionorbreakdown,groundingprovidesapathofleastresistanceforelectriccurrenttoreduce
theriskofelectricalshock.Thissystemisequippedwithacordhavinganequipment-groundingconductorandagroundingplug.Theplugmust
bepluggedintoanappropriateoutletthatisproperlyinstalledandgroundedinaccordancewithalllocalcodesandordinances.
DANGER–Improperconnectionoftheequipment-groundingconductorcanresultinariskofelectrocution.Checkwithaqualifiedelectrician
orservicepersonnelifyouareindoubtastowhethertheoutletisproperlygrounded.Donotmodifytheplugprovidedwiththissystem–ifitwill
notfittheoutlet,haveaproperoutletinstalledbyaqualifiedelectrician.Donotuseanytypeofadapterwiththissystem.
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
TocomplywiththeNationalElectricalCode(NFPA70)andtoprovideadditionalprotectionfromtheriskofelectricshock,thissystemshould
onlybeconnectedtoaproperlygrounded,grounding-typepowersupplyreceptaclethatisprotectedbyaGroundFaultCircuitInterrupter
(GFCI).InspectoperationofGFCIaspermanufacturerssuggestedmaintenanceschedule.
EXTENSION CORDS
Ifanextensioncordisnecessary,useonly3-wireextensioncordsthathave3-pronggrounding-typeplugsand3-polecordconnectorsthat
accepttheplugfromthissystem.Useonlyextensioncordsthatareintendedforoutdooruse.Useonlyextensioncordshavinganelectrical
ratingnotlessthantheratingofthesystem.Acordratedforlessamperesorwattsthanthissystemratingmayoverheat.Exercisecautionwhen
arrangingthecordsothatitwillnotbetrippedoverorpulled.Donotusedamagedextensioncords.Examineextensioncordbeforeusingand
replaceifdamaged.Donotabuseextensioncord.Keepextensioncordawayfromheatandsharpedges.Alwaysdisconnecttheextensioncord
fromthereceptaclebeforedisconnectingthissystemfromtheextensioncord.Neveryankcordtopullplugfromoutlet.Alwaysgrasptheplug
andpulltodisconnect.
WARNING–Topreventriskofelectricalshock,connectthissystemonlytoaproperlygrounded,grounding-
typepowersupplyreceptaclethatisprotectedbyaGroundFaultCircuitInterrupter.Pullplugbefore
servicingorreplacinglamp.Keepallconnectionsdryandofftheground.Donottouchplugwithwethands.
WARNING–Readmanualbeforeinstallingorservicingthissystem.Onlyauthorizedpersonnelpossessinga
strongunderstandingofthissystemshouldattempttoreplacelamporservicethissystem.
WARNING–DonotlookdirectlyatUVlampwhenitisoperating.Thelightemittedbythelampwillcause
seriouseyedamageandburnunprotectedskin.
NOTE–Maximumpressureratingis100PSI(6.89bar)
INSTALLATION
WARRANTYMAINTENANCEOPERATION
OVERVIEW
TABLE OF CONTENTS
Overview 4
Components 4
Specifications 5
Dimensionsandlayout 7
Installation 9
InstallingtheUVsystem 9
Disinfectingthewaterlines 11
Operation 14
Controlpanel 14
Troubleshooting 15
LowUValarms 16
Maintenance 17
Sleevecleaningandlampreplacement 17
Fusereplacement 22
Warranty 23
INSTALLATIONWARRANTY MAINTENANCE OPERATION
OVERVIEW
Power supply
Pro10:part#650629-010G+:part#650629-070G:part#650629-040
Pro20:part#650629-020H+:part#650629-080H:part#650629-050
Pro30:part#650629-030J+:part#650629-090J:part#650629-060
(includeslampcable)
Top bolt & wireform
Part#602916&602896
Sleeve
Pro10,G+,G:part#602974
Pro20,H+,H:part#602975
Pro30,J+,J:part#602976
O-ring
Part#002233
CoolTouch
TM
fan
Part#650630
Sensor
(ProandPlusSeriesonly)
Part#650580
O-ring
Part#002233
Bottom bolt
Part#602984
Lamp
Pro10,G+,G:part#602854
Pro20,H+,H:part#602855
Pro30,J+,J:part#602856
Chamber
Pro10,G+,G:part#650565-003
Pro20,H+,H:part#650565-007
Pro30,J+,J:part#650565-011
Power cord
120V:part#602636
230V:part#602637
For replacement components please contact your
installer (listed on the front of this manual) or contact
Trojan directly for a referral: 1-800-265-5774 (North
America), 519-457-3400, or [email protected].
Sleeve removal tool
Part#602983
Note: keep this tool with
system at all times.
Lamp cable
Part#650631-048
Accessory Part Number
1"SolenoidValve 650627
COMMcentre
RemoteController
(ProSeriesonly)
650623-001
Plug Kit
(ComesinstalledwithBasic
Serieschamber)
COMPONENTS
4
INSTALLATION WARRANTYMAINTENANCEOPERATION
OVERVIEW
SPECIFICATIONS
Operating Parameters
Maximumoperatingpressure 100PSI(689kPa)
Minimumoperatingpressure 10PSI(69kPa)
Maximumambientairtemperature 104
0
F(40
0
C)
Minimumambientairtemperature 32
0
F(0
0
C)
Maximumhumidity 100%
Maximumhardness 120ppm
(7grainspergallon)
Maximumiron 0.3ppm
MinimumUVT 75%
Installation Vertical
Other
Chambermaterial 316LSST
Ratedservicelifeoflamp 2years
Inletandoutlet Combo
1
1
/4"NPT,1"FNPT
General (All Models)
Ratedflow
doseof
30mJ/cm
2
-- -- --
upto19GPM*
(72LPM)
20-39GPM*
(76-148LPM)
40-45GPM*
(151-170LPM)
Ratedflow
doseof
40mJ/cm
2
10GPM
(38LPM)
20GPM
(76LPM)
30GPM
(114LPM)
upto15GPM*
(57LMP)
16-29GPM*
(61-110LPM)
30-44GPM*
(114-167LPM)
Electrical
Voltage 120-240VAC 120-240VAC 120-240VAC 120-240VAC 120-240VAC 120-240VAC
Frequency 50-60Hz 50-60Hz 50-60Hz 50-60Hz 50-60Hz 50-60Hz
Max.current 1.2Amp 1.6Amp 2.4Amp 1.2Amp 1.6Amp 2.4Amp
Max.power
consumption
120Watts 160Watts 230Watts 120Watts 160Watts 230Watts
Lamppower
consumption
100Watts 140Watts 200Watts 100Watts 140Watts 200Watts
Pro10
Pro20
Pro30
G+, G H+, H J+, J
*Flowratesshownareat85%UVT.
5
INSTALLATIONWARRANTY MAINTENANCE OPERATION
OVERVIEW
SPECIFICATIONS
Color-codedplugandplayconnections Yes Yes Yes
UVintensitymonitorwithdiagnostictest Yes Yes --
CoolTouchfan Yes Yes Yes
Dynamicflowrestrictor Yes -- --
Communicationsports(two,RJ45) Yes Yes Yes
COMMcentercontrolpackage Optional -- --
Solenoidvalve Optional Optional Optional
Controls
Audiblealarmmutebutton Yes Yes Yes
Newlampbutton Yes Yes Yes
Lampageindicator Yes Yes Yes
Lampoperationindicator Yes Yes Yes
Ballastoperationindicator Yes Yes Yes
Solenoidoperationindicator Yes Yes Yes
Fanoperationindicator Yes Yes Yes
Sensorreadingindicator Yes Yes --
NSF/ANSI certification
(ProSeriesonly)
Standard55
ClassA
-- --
Other certifications
Pro Series Plus Series Basic Series
6
Seenextpagefordescriptionsofnumberedparts
Inlet
6
1 2
3
54
13
12
b
L
a
Ø
e
d
S
1011
7
8
9
c
Clearancefor
lampremoval(L)
14
INSTALLATIONWARRANTY MAINTENANCE OPERATION
INSTALLATION WARRANTYMAINTENANCEOPERATION
OVERVIEW
DIMENSIONS & LAYOUT
LModel
Pro10,G+,G 21.4"
(55cm)
12"
(30cm)
4"
(10cm)
48"
(122cm)
72"
(182cm)
72"
(182cm)
6.5"
(16.5cm)
13"
(33cm)
Pro20,H+,H 30.8"
(78cm)
12"
(30cm)
4"
(10cm)
48"
(122cm)
72"
(182cm)
72"
(182cm)
6.5"
(16.5cm)
13"
(33cm)
Pro30,J+,J 40.6"
(103cm)
12"
(30cm)
4"
(10cm)
48"
(122cm)
72"
(182cm)
72"
(182cm)
6.5"
(16.5cm)
13"
(33cm)
Ø
edc
(max.)
b
(max.)
a
(max.)
S
(min.)
7
WARRANTYMAINTENANCEOPERATION
INSTALLATIONWARRANTY MAINTENANCE OPERATION
OVERVIEW
Sample valve: Allowsforsamplingofrawwater.
Shut-off valve: Requiredtoallowmaintenanceofpre-treatmentequipment.
Pre-treatment (illustrative only):FortheUVsystemtooperateeffectively,thewatershouldmeetcertain
waterqualityparameters,asoutlinedbelow.Tomeetthese,pre-treatmentofthewatermayberequired.
Pre-treatmentequipmentmustbeinstalledBEFOREtheUVchamber.Pre-treatmentsystemscanbe
comprisedofoneormoreofthefollowingelements:sedimentfilters;carbonfilters;ironremovalsystems;
watersofteners;cystreductionfilters,etc.
Water Quality Requirements:
Iron: <.3PPM(.3mg/L)
Hardness: <120PPM(7GrainsPerGallon)
%UVT: >75%
1
2
3
4
5
Shut-off valve: RequiredtoallowmaintenanceofUVsystem.
Sample valve:AllowsforsamplingofwaterenteringUVchamber;necessaryinordertoconfirmwater
beingtreatedisofadequatequality.
UV chamber:Providesdisinfectionofthewater.MUSTBEINSTALLEDVERTICALLY.
Sensor:OptionalitemthatmonitorsUVoutputtoensureproperdose(UVexposure)isbeingprovided.
Uniquetestfunctionallowsverificationofsensoroperation.
Plug Kit: Astopperforthechamberopeningcreatedforasensorwhennosensorisinuse.
CoolTouch
TM
fan:Removesexcessheatfromstagnantwaterinchamberduringperiodswithoutwaterflow.
Sample valve:AllowsforverificationofsamplingofwaterimmediatelyfollowingUVtreatment;necessaryin
ordertoconfirmproperoperationofUVsystem.
Solenoid valve:OptionalpieceofequipmentsuppliedbyTrojan.Allowswatersupplytobeshut-offwhen
properdisinfectioncannotbeassured.Manualby-passallowsfordisinfectionofwaterlinesusingchlorine
bleach,followinginstallationandmaintenanceprocedures.
Note:Ifthegroundfromtheelectricalpanelistiedtothecopperwaterlines,theuseofasolenoidvalvewillrequire
theinstallationofanapprovedgroundstraptoconnectthetwolinesthathavebeencutinordertomaintaincontinuity.
Checkyourlocalelectricalcodeforthecorrectclampandcablesize.
Shut-off valve: RequiredtoallowmaintenanceofUVsystem.
Power supply:PowersandcontrolstheUVlampandotherdevices.Provideshumaninterface,displaying
informationandallowingcontrolinputs(suchasmutingtheaudiblealarm).
Power source:Providespowertothepowersupply.Forsafetyreasonstheoutletmustbeprotectedby
aGroundFaultCircuitInterrupter(GFCI).NOTE:toprotectthepowersupply,aUL1449certified(or
equivalent)transientvoltagesurgesuppressorisrecommended.
6
7
8
9
10
11
13
12
14
IMPORTANT:
A 5 micron (nominal) sediment filter must be installed
before the UV system and after any water softening equipment
8
INSTALLATION
OVERVIEW
WARRANTYMAINTENANCEOPERATION
INSTALLING THE UV SYSTEM
Determineappropriatelocationofthe
powersupplyandchamber,referringto
Dimensions and Layoutdrawing.Power
supplyshouldbeinstalledhigherthan
chamber.Ensureadequateclearance
abovechambertoallowforremovalofthe
lampandsleeve.
Makeallnecessaryplumbingconnections.
Attachchamber
towallvertically.
4
1
3
2
10
WetO-ring
withwater
thenplace
overtopend
ofsleeve.
5
6
7
8
9
Donottouch
glasswith
barehands.
Insertcurved
endofsleeve
first.Donot
rotatesleeve.
Ensure
sleevebolt
isrotatedfull
1/4turnuntil
positivestop.
Ensure
sleevebolt
isrotatedfull
1/4turnuntil
positivestop.
WetO-ringwith
waterthenplace
overbottomend
ofsleeve.
Only
forPro
andPlus
Series.
1
2
1
2
1
2
9
INSTALLATION
OVERVIEWWARRANTY MAINTENANCE OPERATION
PlugCoolTouchfanintopurplereceptacle.
19
18
20
12
13
14
17
15
1611
Outletmustbe
protectedbya
GroundFault
CircuitInterrupter
(GFCI).
4
1/16
"(10.4cm)
1
2
1
2
Do not touch
glass with
bare hands.
Be sure to
rotate lamp
completely.
Letwaterflowtoonefaucetorotherwater
outlet,thenclosetheoutletandcheckfor
leaks.
ProceedtoDisinfecting The Water Lines.
Lock wireform
into position.
Plugsensor
intobluejack.
(ForProand
PlusSeries
only).
10
INSTALLATION
OVERVIEW
WARRANTYMAINTENANCEOPERATION
DISINFECTING THE WATER LINES
UVsystemsdisinfectthewaterusingultravioletlight,treatingthewaterasitpassesthroughthesystem.When
thereisariskthatwaterdownstreamoftheUVsystemhasbeencontaminateditiscriticalthatthesewaterlines
bechemicallydisinfected.Disinfectionofthewaterlinesisthereforerequiredafterinitialsysteminstallationand
followinganyextendedperiodoftimeduringwhichthesystemisinoperative,whetherduetoanalarmcondition,
apowerfailure,orforanyotherreason.
1
3
Turn on solenoid valve override
(if so equipped).
4
5
6
7
8
2
11
OVERVIEWWARRANTY MAINTENANCE OPERATION
INSTALLATION
16
Gotoawateroutletandallowthecold
watertoflowuntilyoucansmellbleach,
thenstoptheflow.Allowhotwater(if
present)toflowuntilyoucansmellbleach,
thenstoptheflow.Repeatprocedureat
allwateroutlets.Remembertoincludeall
faucets,washingmachines,toilets,outside
taps,andotherwateroutlets.Note:Youwill
likelyrunoutofbleach;ifyoucannotsmell
bleachatagivenoutlet,turnoffthemain
watersupply,depressurizeandaddmore
bleachtothefilterhousing.
Letthebleachsitinthewaterlinesforat
leastfourhours.
9
11
10
12
13
14
15
12
INSTALLATION
OVERVIEW
WARRANTYMAINTENANCEOPERATION
19
20
Flush all water outlets until bleach can no
longer be smelled (at least 5 minutes).
Turn off solenoid valve override (if
so equipped).
17
18
13
INSTALLATION OVERVIEWWARRANTY MAINTENANCE
OPERATION
Indicator lights
Operatingnormally Notapplicable Powersupplyfailure;replacepower
supply
Ballastinactiveduetolampfailure
Operatingnormally Notapplicable Fandisconnected;reconnect
Fanturningslowerthanrequired;
unplugsystem,cleanbladesusing
aQ-tip
Fandamaged;replacefan
Notapplicable
Operatingnormally Warning;lamp
willrequire
replacementshortly
Lampdisconnected;unplugsystem,
reconnectlampandplug-insystem
again
Lampfailure;replacelamp
Lampinactiveduetoballastfailure
UVdoseisadequate
andsensorisoperating
normally
(Pro&Plusmodelsonly)
UVdoseisnearthe
minimumrequired
Sensordisconnected;unplugsystem,
reconnectsensorandplug-insystem
again
UVdoseisbelowminimumrequired,
seeLow UV Alarm section
Sensorinactiveduetolampor
ballastfailure
Solenoidvalveopen
(Ifequippedwith
solenoid)
Notapplicable Solenoidvalvedisconnected;
reconnect
Solenoidcoildamaged;replacecoil
(notentiresolenoid)
Solenoidvalveinactive(closed)
duetofailureofanother
component,inordertoensure
safetyofthewatersupply
Yellow Flashing red Solid redGreen
4
1
3
2
5
Indicator lights only indicate a problem with the component when flashing red.
CONTROL PANEL
4
1
3
5
2
Buttons
Mute Pressthisbuttoninorder
toturnofftheaudible
alarm.Whenthealarmis
duetothelamp'sage,the
mutebuttonwilldeactivate
theaudiblealarmfor7
days;thismayberepeated
uptoamaximumof4
times.
NewLamp Afterinstallinganew
lamp,pressandholdthis
buttonuntilyouheara
beep(aboutfiveseconds).
Thiswillresettheinternal
clock.
Meaning
A
B
Button
A
B
14
INSTALLATION WARRANTYMAINTENANCE
OPERATION
OVERVIEW
TROUBLESHOOTING
Nopower GFCIand/orbreakertripped
Powersupplyfusehasblown
Transientvoltagesurgesuppressor
damaged
Powersupplydamaged
ResetGFCIand/orbreaker
Replacepowersupplyfuse-seeFuse
Replacementsection
Replacetransientvoltagesurge
suppressor(TVSS)
ReplacepowersupplyanduseaTVSS
GFCIorbreaker
repeatedlytrips
Connectionbetweenlampandlampcord
iswet
Short-circuitintheelectricalassembly
Cleananddrythecordandendlamp
pins,checkunitforleaksorcondensation
Replacepowersupply
Leakatinletor
outlet
Threadedpipefittingsareleaking Cleanthreads,resealwithTeflontape
andretighten
Leakdetectedfrom
areaofchamber
Condensationofmoistaironcold
chamber(slowaccumulation)
O-ringdamaged,deterioratedor
incorrectlyinstalled
Sleeveboltnottightenough
Controlhumidityorrelocateunit
Inspectandreplaceifdeteriorated
Ensurenutisturnedcompletely(tostops)
Alarm
SeeControl Panelsection SeeControl Panelsection
Systemisoperating
butwatertests
revealbacterial
contamination
EquipmentdownstreamofUVsystem
isactingasabreedinggroundfor
pathogens
Pathogensareresidinginthedistribution
linespost-UV
Recontaminationfrompipedead-ends
EnsureUVisthelastpieceoftreatment
equipment
Ensurealldistributionlineshave
beendisinfectedwithchlorine-see
Disinfecting the Water Linessection
Removeanypipedead-endsandflush
withchlorine-seeDisinfecting the
Water Linessection
Possible cause Possible solutionSymptom
15
INSTALLATION OVERVIEWWARRANTY MAINTENANCE
OPERATION
Insomecases,short-termflowsoflowultraviolettransmittance(UVT)watercanbecreatedfollowing
andduringtheregenerationcycleofawatersoftener,resultinginasensoralarm.FlushingtheUVsystem
alleviatesthisconditionuntilthesoftenergoesthroughanotherregenerationcycle.Inthelongerterm,the
softener'ssettingsmustbemodified.ToflushtheUVsystem,firstturnthesolenoidvalvebypassswitch(if
equipped)counter-clockwisetooverridetheshut-off,thenopenatapdownstreamandletwaterrunfor
two(2)minutes.Disinfectthewaterlinesfollowingtheproceduresoutlinedunder"Disinfecting The Water
Lines"intheInstallationsection.
ProandPlusSeriesareequippedwithaunique,patentedsensorthatiscapableofself-diagnosis.Simply
pressthebuttonlocatedatthetopofthesensorandholduntiltheaudiblealarmstops(usuallyabout5
seconds).Iftheaudiblealarmisstillpresentafter30seconds,releasethebuttonandreplacethesensor.
RefertoSleeve Cleaning And Lamp ReplacementsectionoftheOwner'sManual.
ContactTrojanoryourwatertreatmentdealerforatestoftheUVTofthewater.
1�
2�
3�
4�
LOW UV ALARMS (Pro & Plus Series Only)
Sensortest
2
Low UV Alarm
Cleansleeve&sensor
3
Audible alarm
Audible alarm
Problem is
corrected
No audible alarm
No audible alarm
CheckUVT
4
ContactTrojan
UVT above 75%
UVT below
recommended
level
Replacesensor
IncreaseUVTusing
pretreatment
Sensoris
operating
normally
Flushsystem
1
Audible alarm
Problem is
corrected
No audible alarm
16
INSTALLATION
OVERVIEW
WARRANTY
MAINTENANCE
OPERATION
Sleeve cleaning
Mineralsinthewaterslowlyformacoatingonthesleeve.Thiscoatingmustberemovedbecauseitreducesthe
amountofUVlightreachingthewater,therebyreducingdisinfectionperformance.Theneedtocleanthesleeve
willbeindicatedbyalowUValarm(flashingredindicatorlightbesidethesensoroncontrolpanel-seeControl
Panelsectionfordetails).
Note:LowUValarmsareforPro&PlusSeriesonly.IfyouownaBasicmodel,pleasecleanthesleeveregulary
(agoodruleofthumbis3-4timesperyear).
Whencleaningisrequired,followtheinstructionsbelowandre-installthecurrentlamp.
Lamp replacement
TheamountofUVlightcreatedbythelampdecreasesovertime,requiringthatthelampbereplaced.The
systemwillautomaticallynotifyyouwhenitistimetoreplacethelamp(thelampshouldlastapproximately24
months).Ifthelamprequiresreplacement,followtheinstructionsbelowandinstallanewlamp.NOTE:TheUV
systemisdesignedtooperatecontinuouslyandshouldnotbeshutoffforshortperiodsoftime,suchasovera
periodoflessthanthreeweeks.
Equipment required:
SLEEVE CLEANING & LAMP REPLACEMENT
Cloth must be
soft, lint-free, and
chemical-free. No
clean-wipes.
Scale remover
such as CLR
TM
or
Lime-Away
TM
.
Screwdirver of any
kind.
Cottom swab. Clean cotton, latex
or plastic gloves
are prefered.
17
INSTALLATION OVERVIEWWARRANTY
MAINTENANCE
OPERATION
4
Letthesystemcoolfor10minutes.
3
2
6
5
1
Solenoidrepresentativeonly.Notonall
systems.
Solenoid
10
7
Close
after all
water has
drained.
8
9
Pinch
wireform to
release it.
18
INSTALLATION
OVERVIEW
WARRANTY
MAINTENANCE
OPERATION
19
Ensure cloth used to clean the sleeve is
soft, lint-free, and contains no chemicals
(no clean-wipes). Sleevemustbereplaced
ifitcannotbecompletelycleanedorifit
appearsscratchedorcracked.
13
1
2
1
12
2
1
11
Do not touch
glass with bare
hands.
2
16
Remove sleeve.
Water will
escape - have
bucket under
chamber.
14
Sleeve removal tool
Insert sleeve
removal tool
into bottom
of sleeve
15
Pry sleeve
upward until it
comes loose.
Some water
will escape.
18
Remove O-ring
from bottom of
chamber.
Remove
O-ring
from top
of sleeve.
17
1
1
19
INSTALLATION OVERVIEWWARRANTY
MAINTENANCE
OPERATION
27
Re-install
current lamp if
it does not need
replacement. Be
sure to rotate
lamp completely.
Do not touch
glass with bare
hands.
1
2
24
1
2
20
1
2
Ensure
sleeveboltis
fullyrotated
untilpositive
stop.
23
1
2
Ensure
sleeveboltis
fullyrotated
untilpositive
stop.
26
1
2
Ensure
sleeveboltis
fullyrotated
untilpositive
stop.
21
Donottouch
glasswith
barehands.
Insertcurved
endofsleeve
first.Donot
rotatesleeve.
25
WetO-ringwith
waterthenplace
overbottomend
ofsleeve.
29
22
WetO-ring
withwater
thenplace
overtopend
ofsleeve.
28
ForBasicSeries,skipto
Step31.
20
/