Royal Sovereign ARP-4009 User manual

Category
Split-system air conditioners
Type
User manual

This manual is also suitable for

Royal Centurian Inc.
PORTABLE AIR CONDITIONER
ACONDICIONADOR DE AIRE PORTÁTIL
Read and retain these instructions for future reference
For any Customer Support needs, please choose
the Support tab on
www.royalsovereign.com
ARP- 4009, 4010, 4012, 4012H
OWNER’S MANUAL
ARP-4009, 4010, 4012, 4012H
PORTABLE AIR CONDITIONER
Página en Español 17
Page en Français 33
PORTABLE AIR CONDITIONER
Model ARP-4009, 4010, 4012, 4012H
INTRODUCTION
Thank you for choosing Royal Sovereign to provide you and your family with all of the “Home Comfort” requirements for your home, apartment,
or office. This Portable Air Conditioner can be set-up in just minutes and can be easily moved from room to room. It is a multi-functional room
air comfort system that offers you Air Conditioning, Dehumidification and Air Circulation modes. This manual will provide you with valuable
information necessary for the proper care and maintenance for your new appliance. Please take a few moments and read the instructions
thoroughly. If properly maintained, your appliance will give you many years of troublefree operation.
Precautions for use
Electrical Specifications and Power Cord
Check to ensure that the electrical service being used is adequate for the model you’ve chosen. The electrical rating of your new air conditioner is
defined on the serial plate of the unit. Please refer to the rating when checking electrical requirements to ensure they meet the electrical codes of
your location.






qualified electrician install the proper outlet.





General Use






4
ARP-4009, 4010, 4012, 4012H
Notes on operation
If you turn the air conditioner off and immediately restart it, allow 3 minutes for the compressor to restart cooling. In the event of a power failure, wait 3 minutes before restarting
unit.
Identification of parts
1. Air outlet
2. Display panel
3. Handle
4. Caster
5. Air filter



9. Water outlet drain
10. Power supply cord
5
Installation
Unpack your new Portable Air Conditioner and let the machine stand upright for 2 hours before starting.
Unpack all parts listed below. If any parts are missing do not return this product to the place of purchase.
Please visit our website www.royalsovereign.com and click on the “Customer Support” tab and
“Make a Request” to request missing parts or call 1-800-397-1025 and press option #4 to order these parts.
Accessories Include
1. Window slider kit1 Set
2. Screws6 Pieces
1 Pieces
 1 Pieces
1 Piece
6. Cover1 Piece
A. Exhaust Hose and Connector : Fig 1.

2. Repeat for other end.
B. Attach Hose Fixture : Fig 2.


Fig 1.
Fig 2.
6
ARP-4009, 4010, 4012, 4012H
C. Install the Window Slider Kit : Fig 3.
1. Op en the window and place the Window Slider Kit on the inside edge of the window.
2. Adjust the Window Slider by adjusting it to the width of the window.
3. Close the window to secure.
4. Tighten the two screws to lock the window slider in place.
D. Connecting the Exhaust Hose to the PAC : Fig 4.
1. Connect the hose connector to the air outlet by aligning the tabs on the hose to the PAC and snap it into place.
E. Connect the Exhaust Hose to Window Slider Kit : Fig 5.
1. Move the Portable Air Conditioner within 4 feet of the window.


Fig 3.
Fig 4.
Fig 5.
7
Operation
Control Panel
8
Power Control
The power control button turns the unit on and off. When you press the button, the unit begins to operate.
Mode Control

Cool Mode
Press the Mode Control button to select Cool mode. The green light will show on the display.
The unit displays “present room temperature.” The temperature range settings are between 64~88 °F
A. In Cool mode, use the
or button to adjust and set the desired temperature for the room. After 3 seconds the display will return back to the present room temperature.
NOTE:
Dry (Dehumidify) Mode

When the Dehumidify mode is on, the temperature buttons do not function. The fan speed can be adjusted only if the temperature in the room is higher then 77 ° F. If it is below this temperature, the

NOTE: 
Fan Mode
Press the Mode Control button to select Fan mode. The light will show on the display. The air is circulated throughout the room with no cooling.
Heat Mode (only ARP-4012H)
Press the Mode Control button to select Heat mode. The red light will show on the display.
The unit displays “present room temperature”. Heating is only activated when the temperature in the room is below 81° F. The temperature setting can be adjusted between 64 and 81° F.
B. In Heat mode, use the
or button to adjust and set the desired temperature for the room. After 3 seconds the display will return back to the current room temperature.
NOTE:
Timer set control
Tenperture control set
Power control
LCD display
Oscillation mode
Sleep mode
Fan speed control
Mode control
Auto Cool
Dehumidify
Fan / Heat
ARP-4009, 4010, 4012, 4012H
Fan Speed Control
Press the Speed button to set the fan speed. The fan settings are low, medium, and high.
NOTE: The air will be circulated without cooling or heating and the unit does not have to be vented for this mode.
Timer
There are 2 different timer programs. You can set the number of hours before the air conditioner automatically turns OFF or you can set the number of hours that will elapse before the unit turns ON.
When the air conditioner is turned off, you can choose to turn it on in one hour intervals.


press the button until you see 8 on the display.
3. The unit will turn on when the set time elapses
When the air conditioner is turned on, you can choose to turn it off in one hour intervals.


press the button until you see 8 on the display.
3. The unit will turn off when the set time elapses
Oscillation Mode
The oscillation feature moves the air louvers from left to right to allow the air to reach more areas in the room. Press the OSC button to start this feature.
Sleep Mode
Sleep Mode is used to keep the room comfortable while saving energy. When the Sleep Mode button is pressed, the set temperature will increase by 2 ° F in the first hour and increase another 2° in
the second hour. It will then remain at that temperature for the remainder of the night.
Tank Full


Automatic Restart

Power Plug Check
1. Press the RESET button.
2. Insert the power plug into the electrical outlet.
3. Press the TEST button. If the circuit breaker is working you’ll hear a click.
4. Press the RESET button until you hear another click. The circuit breaker in the plug is now activated.
5. Do not use the air conditioner if the above procedure cannot be successfully performed.
After switching the air conditioner off, wait 3 minutes before switching it back on again.
9
Remote Control
All functions can be accessed from the remote control.
10
Sleep mode
Oscillating button
Mode button
Power control
Timer button
Temperature UP button
Temperature DOWN button
Fan speed control
ARP-4009, 4010, 4012, 4012H
11
Remote Control Operation

- Remove the battery cover on back of the remote.

- Replace the battery cover.
Notes:
-When replacing batteries, always change both batteries at the same time.
-Remove the batteries if the remote control is not used for a month or longer.
-Do not dispose of batteries in a fire.
Battery replacement

Battery compartmentBattery compartment lid
12
Maintenance
Drainage
Occasionally, you may need to drain the unit.
1. Drain the unit if the Warning Light on the display panel of the air conditioner is on.
2. Turn off the power to the unit and unplug.
3. Place a shallow dish under the drainage plug to collect water.
4. Remove the drainage plug.
5. Replace the plug, when drainage water stops flowing.
Cleaning the filter
The filter should be cleaned every 2 weeks or 100 hours of use in order to maintain proper airflow.
1. Remove the filter. Gently pull the filter assembly from the back of the unit and then remove the filter from the assembly.
2. Cle an the filter by vacuuming or a soft cloth. If the filter is very dirty, it can be easily washed with a mild detergent and rinsed thoroughly with clean water. Dry the filter before
replacement.
3. Reinstall the filter in the filter assembly.
4. Replace the filter assembly on the back of the machine.
Note
Cleaning and maintaining the air conditioner
Turn the air conditioner off and remove the electrical plug. Wipe with a soft, dry, or damp cloth. A mild detergent can be used. Be sure to remove any residue and dry completely.

Storing the air conditioner
If the unit will not be used for a long time, be sure to drain the air conditioner, clean the air filter, pull out the power supply plug, and remove the batteries from the remote control
before storage. After draining, keep the air conditioner running on FAN mode for at least 8 hours to dry the unit completely to prevent mold.
ARP-4009, 4010, 4012, 4012H
Troubleshooting
Problem Possible Reasons
Air Conditioner does not operate
- Check and reset the power plug. Wait 3 minutes and try to run the unit again.
- The batteries in the remote may need to be replaced. Replace the batteries and try to run the unit again.
- Make sure the plug is properly plugged into the outlet.
- The set temperature may be too close to room temperature. Lower the set temperature.
- The air outlet may be blocked. Check the air outlet and remove any items that may be found.
Air Conditioner runs but does not cool
- Check the room for open doors or windows and close them.
- There may be another appliance in the room giving off heat. Check the room and turn off the appliance.
- The air filter may be dirty. Check the filter and clean if necessary.

- The set temperature may be too high. Check the set temperature and reduce it if necessary.
Air Conditioner does not run
and water full indicator is lit

13
14
SPECIFICATIONS
- Figures noted in the contents are for reference only; variation may result due to the application in different countries or regions, and shall be based on practical operation.
“Electrical waste products should not be disposed of with household waste.

Description of product Air Conditioner
Model ARP-4009 ARP-4010 ARP-4012 ARP-4012H
 
Input power 1050W 1470W 1700W 1700W
Current 9.1A 12.8A 14.8A 14.8A
Cooling Capacity 9,000BTU/hr 10,000BTU/hr 12,000BTU/hr 12,000BTU/hr
Dehumidifying Capacity 4.4 pints/hr
Coolant R-22
Timer 24 hour
 
Weight 77lbs
ARP-4009, 4010, 4012, 4012H
FULL ONE YEAR WARRANTY
Royal Sovereign warrants each Portable Air Conditioner to be free from defects in material and workmanship. Our obligation under this warranty is limited to the repair or

in effect to the original purchaser, for a period of one year from the date of purchase and is not transferable. This warranty shall apply only if the air conditioner is used on

To request servies, please go to www.royalsovereign.com - Customer Support to submit a request or call 1-800-397-1025
LIMITED FIVE YEAR WARRANTY (COMPRESSOR)
For a period of five years from the date of purchase, when this Royal Sovereign Portable Air Conditioner is operated and maintained according to the instruction manual provided

material. If repair becomes necessary, please contact our customer service center. You will be responsible for all freight, insurance, and any other transportation charges to get the
unit to our factory or service center. If shipping is required, be sure to pack the unit properly to avoid shipping damages, as we will not be responsible for such damages.
EXCLUSIONS

centers, mishandling, improper installation, modification or unreasonable use including incorrect voltage, acts of God, or failure to provide reasonable and necessary maintenance.


rights which vary from state to state.
SERVIES CONTACT and FAQ'S
Please visit www.royalsovereign.com - USA - Customer Support for out of warranty service or to view prequently asked questions.
15
ROYAL SOVEREIGN INTERNATIONAL, INC.


ROYAL SOVEREIGN INC.
1001, World Meridian II, 426-5, Gasan-dong, Geumcheon-gu, Seoul, 153-759, KOREA

RS INTERNATIONAL AUSTRALIA PTY. LTD.
30 Prime Drive, Seven Hills, NSW 2147, AUSTRALIA
 
RS CANADA INC.
164 Oakdale Road, Toronto, Ontario M3N 2S5 CANADA
 
RS Holland B.V.
Industrieweg 6K, 4104AR, Culemborg, The Netherlands

Royal Sovereign Mexico, S.A. de C.V.


Royal Centurian Inc.
ACONDICIONADOR DE AIRE PORTÁTIL
Lea y guarde estas instrucciones para referencia en el futuro.
Para Servicio al Cliente por favor diríjase a nuestra página web HYPERLINK
“http://www.royalsovereign.com”
www.royalsovereign.com
y seleccione “Support Tab”
ARP- 4009, 4010, 4012, 4012H
MANUAL DEL PROPIETARIO
ARP-4009, 4010, 4012, 4012H
ACONDICIONADOR DE AIRE PORTÁTIL
ROYAL SOVEREIGN INTERNATIONAL, INC.


ROYAL SOVEREIGN INC.
1001, World Meridian II, 426-5, Gasan-dong, Geumcheon-gu, Seoul, 153-759, KOREA

RS INTERNATIONAL AUSTRALIA PTY. LTD.
30 Prime Drive, Seven Hills, NSW 2147, AUSTRALIA
 
RS CANADA INC.
164 Oakdale Road, Toronto, Ontario M3N 2S5 CANADA
 
RS Holland B.V.
Industrieweg 6K, 4104AR, Culemborg, The Netherlands

Royal Sovereign Mexico, S.A. de C.V.


ROYAL SOVEREIGN INTERNATIONAL, INC.


ROYAL SOVEREIGN INC.
1001, World Meridian II, 426-5, Gasan-dong, Geumcheon-gu, Seoul, 153-759, KOREA

RS INTERNATIONAL AUSTRALIA PTY. LTD.
30 Prime Drive, Seven Hills, NSW 2147, AUSTRALIA
 
RS CANADA INC.
164 Oakdale Road, Toronto, Ontario M3N 2S5 CANADA
 
RS Holland B.V.
Industrieweg 6K, 4104AR, Culemborg, The Netherlands

Royal Sovereign Mexico, S.A. de C.V.


  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Royal Sovereign ARP-4009 User manual

Category
Split-system air conditioners
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI