NGS Fortress 900 User manual

Category
Uninterruptible power supplies (UPSs)
Type
User manual

This manual is also suitable for

ENGLISH · FRANÇAIS · ESPAÑOL · DEUTSCH
ITALIANO · PORTUGUÊS · POLSKI
UPS
FORTRESS
PROTECT YOUR EQUIPMENT
AGAINST POWER FAILURE
USER’S
MANUAL
USER’S MANUAL
2
REMARKS ABOUT SAFETY
In order to keep safe in using the UPS, please comply with the
following:
• Pleasechargethebatteryatleast12hoursbeforetheUPSis
inoperation.
• Afterthebatteryisdischargedoroverthreemonthswithou
toperarion,thebatteryshouldbechargedimmediatelyfor
atleast12hours,ensuringthebatteryisfullandavoidingany
unnecessarydamageofthebattery.
• WhenACfailsandtheONbuttononthefrontpanelispressed,
theUPSwilloutputvoltage;iftheOFFbuttononthefront
panelispressed,theUPSwillnotoutputvoltage.
SAVE THESE INSTRUCTIONS
Thismanualcontainsimportantsafetyinstructions.Please
followallinstructionscarefullyduringinstallation.Readthis
manualthoroughlybeforeattemptingtounpack,installor
operate.
CAUTION Topreventtheriskofreorelectricshock,
installinatemperatureandhumiditycontrolled
indoorarea,freeofconductivecontaminants.
CAUTION Riskofelectricshock,donotremovethecover.
Nouserserviceableparts.Referservicingto
qualiedservicepersonnel.
CAUTION Riskofelectricshock,hazardousliveparts
insidethisUPScanbeenergizedfromthe
batterysupplyevenwhentheinputACpower
isdisconnected.
CAUTION Riskofelectricshock,BatteryCircuitisnot
isolatedfromACinput;hazardousvoltagemay
existbetweenbatteryterminalsandground.
Testbeforetouching.
WARNING ThisisaClassA-UPSProduct.Inadomestic
environment,thisproductmaycauseradio
interference,inwhichcase,theusermaybe
requiredtotakeadditionalmeasures.
NOTICE TheUPSisdesignedtobeforusewith
computerloadsonly.
NOTICE Topreventinjury,donotcarrywiththehandle
offrontcoverwhenmovingtheUPS.
ENGLISH
3
Model FORTRESS 600 / 800 / 900
DC voltage of long backup 12VDC
Type of load Computer,displayer
Input voltage 230V
Input frequency 50Hz
Output voltage 230V
Output frequency 50/60Hz0.5Hz(inbatterymode)
Power factor PF=0.6(wheninputrange-35%to
-23%,PF=0.45)
Backup time 5-10minutes
(dependsoftheload)
Transfer time 10ms
Short-circuit protection FuseinACmode,limitedoutput
currencyininvertermode
Efficiency of power >80%ininvertermode
Temperature 0°C~40°C
Humidity 10%~90%
Display LEDdisplay:AC,charging,
inverting
MAIN SPECIFICATIONS
FORTRESS 600 500VA/300W Battery:NP7Ah/12V
FORTRESS 800 650VA/390W Battery:NP7.2Ah/12V
FORTRESS 900 750VA/450W Battery:NP7.2Ah/12V
MODEL SPECIFICATIONS
INTRODUCTION
Off-line UPS LED
1. BatterychargingLed:itlitswhentheUPSispluggedtothe
mains.
2.PowerfailureLed:itlitswhentheUPSdetectsapowercut.
3.PowerONLed:itlitswhenyouturnontheUPS.Itshowsthe
poweroutputisworking.
4.ON/OFFbutton:turnsUPSonando.
Pressandreleasetoturnon
Pressandreleasetoturno
2
31
4
USER’S MANUAL
4
Fuse
Input
Output
INSTALLATION AND OPERATION
Installation for Standard UPS
1. Shutdowntheload(forexamplePC),pulloutpowergird.
2.PutUPSontheproperposition(followingthemanual).
3.Connectload(forexamplePC)totheUPS.
4.PuttheplugtotheACpowersocket(makesureGNDis
connectedwell).
5.ConnecttoAC:pressthepanelswitchturningontheUPS,
thegreenLEDandyellowLEDlight,thenyoucanturnonyour
computeretc.
6.Batterymode:pressthepanelswitchturningontheUPS,the
redLEDlights,thenyoucanturnonyourcomputeretc.
7.NormallyturningUPS:pressthepanelswitchturningonthe
UPS.
8.NormallyturningoUPS:pressthepanelswitchturningo
theUPS.
ENGLISH
5
Phenomenon Trouble Shooting
Batteryfailstosupplypower. Checkwhetherthebatteryisn’tchargedchargeenough.
CheckwhethertheUPSisnotturnedoncorrectly.
UPSdoesn’tturntoAC(theinputplugoftheUPShasbeen
pluggedintotheACsocketandACisnormal,andtheON
buttonhasbeenpressed,buttheACindicatinglightisnot
brightandthealarmbeeps.
Checkwhetherthefuseisbroken?Thefuseisplacedonthe
UPSbackpanel.AfterdisconnectingtheACplug,putoutthe
fuseandcheckwhetherthefuseisbroken,ifso,pleasereplace
itwithanewfuse.
WhenACfails,thecomputerdoesn’twork. PleaseturnontheUPSandchargethebatteryforatleast10
hours,whenACisnormalandthenturnontheUPS.
ACoutputisnormal,butthealarmbeeps. ACisovervoltageorlowvoltage.
HANDLING OF ABNORMITY
TheUPScanserveandprovideprotectiontousers’equipment,
butifthereissomethingabnormal,pleaseturntolocalUPS
dealerforhelp,avoidingunnecessarydamagetotheUPS.
WhentheUPShasthefollowingproblems,pleasefollowthe
stepsbelowandiftheproblemstillcannotbesolved,please
contactthelocaldealer.
www.ngs.eu
www.ngstechnology.com
technical support: www.ngs.eu/support
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

NGS Fortress 900 User manual

Category
Uninterruptible power supplies (UPSs)
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI