Campbell Hausfeld HU502000 User manual

Category
Air compressors
Type
User manual

This manual is also suitable for

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
IN633701AV 6/10
See Warranty on page 10 for important information about commercial use of this product.
Operating Instructions HU500000, HU502000
© 2010 Campbell Hausfeld/Scott Fetzer For parts, product & service information,
visit www.chpower.com
Oilless Compressors
Description
This residential oilless compressor is
designed for do-it-yourselfers with a
variety of home and automotive jobs.
These compressors power spray guns,
impact wrenches and other tools.
Compressed air from this unit will
contain moisture. Install a water filter
or air dryer if application requires dry
air.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make sure
to tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance. Have the serial number,
model number, and parts list (with
missing parts circled) before calling.
DO NOT RETURN
THE PRODUCT TO
THE RETAILER!
Do not operate unit
if damaged during
shipping, handling or use. Damage may
result in bursting and cause injury or
property damage.
READ & FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DO NOT DISCARD
Breathable Air Warning
This compressor / pump is not equipped and should not be used “as is”
to supply breathing quality air. For any application of air for human
consumption, the air compressor / pump will need to be fitted with
suitable in-line safety and alarm equipment. This additional equipment
is necessary to properly filter and purify the air to meet minimal
specifications for Grade D breathing as described in Compressed Gas
Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 1910.
134, and / or Canadian Standards Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used for the purpose of breathing air
application and proper in-line safety and alarm equipment is not
simultaneously used, existing warranties shall be voided, and the
manufacturer disclaims any liability whatsoever for any loss, personal
injury or damage.
STOP!
Record the Model No., Serial No. and date of purchase in the space
below.
Model No. ____________________
Serial No. ____________________
Date of purchase ____________________
Retain these numbers for future reference.
2
Operating Instructions
www.chpower.com
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates
a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
NOTE: Information that requires special
attention.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or its
power cord may
contain chemicals, including lead,
known to the State of California to
cause cancer and birth defects or other
reproductive harm. Wash hands after
handling.
You can
create
dust when you cut, sand, drill
or grind materials such as
wood, paint, metal, concrete,
cement, or other masonry. This dust
often contains chemicals known to
cause cancer, birth defects, or other
reproductive harm. Wear protective
gear.
GENERAL SAFETY
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure pumping
system, the following safety precautions
must be observed at all times:
Do not run
unattended. Leaving
compressor in AUTO position may allow
it to turn on inadvertently. To prevent
this and possible damage from power
surge, turn to OFF position after each
use.
1. Read all manuals included
with this product carefully.
Be thoroughly familiar
with the controls and the
proper use of the equipment.
2. Follow all local electrical and safety
codes as well as in the United States,
the National Electrical Codes (NEC)
and Occupational Safety and Health
Act (OSHA).
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
5. Wear safety glasses and
use hearing protection
when operating the unit.
6. Do not stand on or use the unit as a
handhold.
7. Before each use, inspect compressed
air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or
replace defective items before using.
8. Check all fasteners at frequent
intervals for proper tightness.
Motors,
electrical
equipment and controls can
cause electrical arcs that
will ignite a flammable gas
or vapor. Never operate or repair in or
near a flammable gas or vapor. Never
store flammable liquids or gases in the
vicinity of the compressor.
Compressor parts may be hot
even if the unit is stopped.
9. Keep fingers away from a
running compressor; fast moving
and hot parts will cause injury and/
or burns.
10. If the equipment should start to
vibrate abnormally, STOP the engine/
motor and check immediately for
the cause. Vibration is generally a
warning of trouble.
11. To reduce fire hazard,
keep engine/motor
exterior free of oil,
solvent, or excessive
grease.
Never remove or
attempt to adjust
safety valve. Keep safety valve free
from paint and other accumulations.
Never use plastic
(PVC) pipe for
compressed air. Serious injury or death
could result.
Never
attempt
to repair or modify a tank!
Welding, drilling or any other
modification will weaken the
tank resulting in damage from rupture
or explosion. Always replace worn,
cracked or damaged tanks.
Drain liquid from
tank daily.
12. Tanks rust from moisture build-up,
which weakens the tank. Make sure
to drain tank regularly and inspect
periodically for unsafe conditions
such as rust formation and corrosion.
13. Fast moving air will stir up dust
and debris which may be harmful.
Release air slowly when draining
moisture or depressurizing the
compressor system.
MANUAL
3
HU500000, HU502000
www.chpower.com
General Safety Information
(Continued)
SPRAYING PRECAUTIONS
Do not
spray
flammable materials in
vicinity of open flame or near
ignition sources including the
compressor unit.
14. Do not smoke when spraying paint,
insecticides, or other flammable
substances.
15. Use a face mask /
respirator when spraying
and spray in a well
ventilated area to prevent
health and fire hazards.
16. Do not direct paint or other sprayed
material at the compressor. Locate
compressor as far away from
the spraying area as possible to
minimize overspray accumulation on
the compressor.
17. When spraying or cleaning with
solvents or toxic chemicals, follow
the instructions provided by the
chemical manufacturer.
WHEEL ASSEMBLY (Figures 3 and 4)
Wheel assembly kit includes:
- 2 wheels *
- 2 axle bolts *
- 2 washers *
- 2 nuts *
- 2 wheel inserts *
The items marked with an asterisk (*)
were shipped loose with the unit.
1. Wheel has an offset hub. Place
wheel insert into center of hub. With
offset hub facing axle iron, assemble
axle bolt through washer and then
holes in wheel and axle iron.
2. Place lock washer on axle bolt. Then
tighten nut securely to threaded part
of axle bolt.
3. Repeat procedure with other side.
Assembly
HANDLE ASSEMBLY (Figures 1 and 2)
1. Place ends of handle around tank
and into the mounting pipe. Align
holes in handle to holes in mounting
pipe.
2. Assemble four (4) screws (from parts
package) through holes in mounting
pipe and handle. Tighten screws.
Never use the
handle to lift the
unit completely off the ground. Only
use the handle to lift one end so the
wheels may be used to move the unit.
Figure 3 - Wheel Assembly
(horizontal unit)
Nut
Wheel
Wheel Insert
Washer
Axle Bolt
Axle Iron
Figure 1 - Handle Assembly
(horizontal unit)
Screws
Figure 2 - Handle Assembly
(vertical unit)
Screws
Figure 4 - Wheel Assembly
(vertical unit)
Nut
Wheel
Wheel Insert
Washer
Axle Bolt
Axle Iron
4
Operating Instructions
www.chpower.com
Introduction
Refer to Figure 5 to locate the following
items.
Pressure Switch - Auto/Off Switch - In
the "AUTO" position, the compressor
shuts off automatically when tank
pressure reaches the maximum preset
pressure. In the "OFF" position, the
compressor will not operate. This switch
should be in the "OFF" position when
connecting or disconnecting the power
cord from the electrical outlet.
Regulator - The regulator controls
the amount of air pressure at the hose
outlet.
ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
Exhaust Tube - This tube carries
compressed air from the pump to the
check valve. This tube becomes very hot
during use. To avoid the risk of severe
burns, never touch the discharge tube.
Check Valve - One-way valve that
allows air to enter the tank, but
prevents air in the tank from flowing
back into the compressor pump.
Handle - Designed to move the
compressor.
Never use the
handle on wheeled
units to lift the unit completely off the
ground.
Drain Valve - This valve is located on
the bottom of the tank. Use this valve
to drain moisture from the tank daily to
reduce the risk of corrosion.
Pressure Gauges - These gauges will
show air pressure in the compressor
tank and at the compressor outlet.
Outlet Pressure Gauge - Will show
air pressure at the outlet in pounds per
square inch (psi). Make sure this gauge
reads ZERO (by adjusting regulator
knob fully counterclockwise) before
changing air tools or disconnecting air
hose from outlet.
Tank Pressure Gauge - Will show air
pressure in tank while the compressor
is running, indicating compressor
is building pressure properly. This
gauge will show maximum pressure
of compressor when it shuts off
automatically at the pressure switch.
Motor Reset - (not shown, located
inside motor). Designed to keep the
motor from overheating. The motor has
an auto reset protector. To reset once
the motor has cooled, turn the pressure
switch to the OFF position, then to the
AUTO position.
This compressor is
equipped with an
overload protector which will shut off
motor if it becomes overloaded.
If the overload
protector is
actuated, the motor must be allowed to
cool down for approximately 30 minutes
before it will reset.
Figure 5 - Unit Identification
Drain Valve
Drain Valve
Handle
Regulator
Safety Valve
Pressure Switch
(AUTO / OFF)
Check Valve
Outlet
Gauge
Tank
Gauge
Check Valve
Regulator
Safety Valve
Pressure Switch (AUTO / OFF)
Outlet Gauge
Tank Gauge
Handle
5
HU500000, HU502000
www.chpower.com
Installation
LOCATION
It is extremely important to install the
compressor in a clean, dry, and well
ventilated area. The compressor must
be placed on a firm, level surface where
the surrounding air temperature will
not be more than 100°F.
A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could obstruct
air flow.
Do not locate the
compressor air inlet
near steam, paint spray, sandblast areas
or any other source of contamination.
This debris will damage the motor.
ELECTRICAL INSTALLATION
All wiring
and
electrical connections should
be performed by a qualified
electrician. Installation must
be in accordance with local codes and
national electrical codes.
WIRING
1. Local electrical wiring codes
differ from area to area. Source
wiring, plug and protector must
be rated for at least the amperage
and voltage indicated on motor
nameplate, and meet all electrical
codes for this minimum.
2. Use a slow blow fuse or a circuit
breaker.
3. This product is for use on a
nominal 120 volt circuit and has
a grounding plug that looks like
the plug illustrated in Figure 6.
Make sure the product is connected
to an outlet having the same
configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire
for electric current. This product
is equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be
plugged into an outlet that is
properly installed and grounded in
accordance with all local codes and
ordinances.
Overheating, short
circuiting and fire
damage will result from inadequate
wiring.
TEST
RESET
Figure 6 - Grounding Method
Grounded Outlet
Grounding Pin
Operation
BEFORE FIRST START-UP
BREAK-IN PROCEDURE
(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to repeat.)
1. Open drain valve located on bottom
of tank.
2. Turn ON / OFF switch to OFF
position.
3. Plug in power cord.
4. Turn ON / OFF switch to ON position
and run compressor for 30 minutes.
5. Turn ON / OFF switch to OFF
position.
6. Unplug power cord.
7. Close drain valve.
The compressor is now ready for use.
OPERATING PROCEDURE
1. Turn switch to OFF position and plug
in power cord.
2. Turn regulator knob
counterclockwise to close air flow.
3. Turn switch to AUTO position.
4. Compressor will build to maximum
pressure and shut off.
5. With hose attached to outlet of
compressor, attach tire chuck or
other tool to open end of hose.
6. Adjust regulator to proper pressure
for tool or tire. Operate tool per
instructions.
As air is depleted from the tank by
use of a tire chuck, tool, etc., the
compressor will restart automatically
at its preset “cut-in” pressure. When
a tool is being used continuously,
the compressor will cycle on and off
automatically.
7. Turn switch to OFF position, unplug
power cord and drain tank of air
when finished using compressor.
Minimum Gauge of Extension Cord
25 ft. 50 ft. 100 ft.
14 12 10
Use of an extension cord may cause excess
heat to motor. This could lead to tripped
breaker (at electrical panel) or tripped
thermal overload (on compressor motor).
If this occurs, eliminate extension cord and
plug compressor directly into electrical
outlet. Avoid using extension cords; use
longer air hose(s) instead.
6
Operating Instructions
www.chpower.com
Maintenance
Disconnect, tag and lock out
power source, then release
all pressure from the system
before attempting to install, service,
relocate or perform any maintenance.
Check compressor often for any visible
problems and follow maintenance
procedures each time compressor is
used.
ASME SAFETY VALVE
Do not remove or
attempt to adjust
the safety valve!
Check the safety valve by performing
the following steps:
1. Plug the compressor in and run until
shut off pressure is reached.
2. Wearing safety glasses, pull the
ring on the safety valve to release
pressure from compressor tank. Use
your other hand to deflect fast-
moving air from being directed
toward your face.
3. The safety valve should
automatically close at approximately
40 psi - 50 psi. If the safety valve
does not allow air to be released
when you pull on the ring, or if
it does not close automatically, it
MUST be replaced.
Safety valve must be
replaced if it cannot
be actuated or it leaks air after ring is
released.
DRAIN TANK
1. Turn compressor off and release
pressure from system. (To release
pressure from system, pull ring on
ASME safety valve. Deflect escaping
air by shielding valve with one hand
as you pull ring with other hand.)
Pull ring until tank is empty.
A large amount of
fast moving air will
be released when the safety valve is
opened with pressure in the tank. Wear
ANSI approved Z87.1 safety glasses.
2. Drain moisture from tank by
opening drain valve underneath
tank. Tilt tank to remove all
moisture.
3. Clean dust and dirt from tank,
air lines and pump cover while
compressor is still OFF.
INTAKE AIR FILTER MAINTENANCE
Removal, Inspection and Replacement
(Figure 8).
The intake filter element should be
removed and checked periodically.
A clogged intake filter can decrease
compressor performance and cause the
compressor to overheat.
1. Remove bolt.
2. Remove the filter cover and filter
element. Inspect each piece.
3. If the filter element is dirty or
clogged, replace it.
4. Reinstall filter, cover, and bolt.
IMPORTANT: Locate unit as far from
spraying area as hose will allow to
prevent overspray from clogging filter.
END OF OPERATION/STORAGE
1. Turn AUTO/OFF switch to the OFF
position.
2. Unplug power cord from wall outlet
and wrap around handle to prevent
damage when not in use.
3. Wearing safety glasses drain tank of
air by pulling the ring on the safety
valve. Use other hand to deflect
fast moving air from being directed
toward your face.
4. Drain tank of condensation by
opening drain valve on bottom of
tank. Tank pressure should be below
10 psi when draining tank.
5. Air hose should be disconnected
from compressor and hung open
ends down to allow any moisture to
drain.
6. Compressor and hose should be
stored in a cool, dry place.
TECHNICAL SERVICE
For information regarding the operation
or repair of this product, please call
1-800-543-6400.
Figure 7
Figure 8 - Intake Filter Maintenance
Filter
Cover
Filter
Element
Bolt
7
HU500000, HU502000
www.chpower.com
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form
into droplets as it comes from an air
compressor pump. When humidity
is high or when a compressor is in
continuous use for an extended
period of time, this moisture will
collect in the tank. When using a
paint spray or sandblast gun, this
water will be carried from the tank
through the hose, and out of the
gun as droplets mixed with the spray
material.
IMPORTANT: This condensation will
cause water spots in a paint job,
especially when spraying other than
water based paints. If sandblasting, it
will cause the sand to cake and clog
the gun, rendering it ineffective.
A filter in the air line, located as
near to the gun as possible, will help
eliminate this moisture.
MAINTENANCE SCHEDULE
OPERATION DAILY WEEKLY MONTHLY
DRAIN TANK
l
CHECK AIR FILTER
l
CHECK SAFETY VALVE
l
CLEAN UNIT
l
Maintenance (Continued)
Notes
8
Operating Instructions
www.chpower.com
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Compressor will not
run
1. Switch in OFF position 1. Make sure compressor is plugged in and switch is ON.
2. No electrical power at wall
outlet
2. Check circuit breaker or fuse at electrical panel.
3. Compressor has reached
automatic shut-off pressure
3. Release air from tank until compressor restarts
automatically.
4. Motor overheated 4. Allow compressor to cool for approximately 30 minutes so
thermal overload switch will reset. Make sure compressor
is run in a clean, well-ventilated area where temperature
will not exceed 100°F.
5. Loose electrical connection 5. Check all electrical connections.
6. ON / OFF switch bad 6. Replace ON / OFF switch.
7. Pressure switch bad 7. Replace pressure switch.
8. Defective motor 8. Replace pump / motor assembly.
Fuses blow / circuit
breaker trips
repeatedly
1. Incorrect size fuse, circuit
overloaded
1. Check for proper fuse, use time-delay fuse. Disconnect
other electrical appliances from circuit or operate
compressor on its own branch circuit.
2. Extension cord usage - wrong
gauge wire and/or too long
2. Remove extension cord or refer to Extension Cord Chart on
page 5.
3. Worn check valve 3. Replace check valve.
Do not disassemble check valve with
air pressure in tank; bleed tank.
4. Defective unloader valve (on
pressure switch)
4. Replace unloader valve.
5. Defective motor capacitor(s) 5. Replace capacitor(s).
6. Defective motor 6. Replace motor.
Tank pressure drops
when compressor
shuts off
1. Loose connections (fittings,
tubing, etc.)
1. Check all connections with soap and water solution.
Tighten; or remove and apply pipe dope or pipe tape to
the threads, then reassemble.
2. Open tank drain valve 2. Close tank drain valve.
3. Tank leaks 3. Check tank for leaks with soap and water solution. If
leak is detected, tank must be replaced with genuine
replacement part.
Compressor runs
continuously and / or
air output is lower
than normal / low
discharge pressure
1. Excessive air usage 1. Decrease air usage; compressor not large enough for air
requirement.
2. Clogged intake filter 2. Clean or replace filter.
3. Open tank drain valve 3. Close tank drain valve.
4. Air leaks in piping (on machine
or in outside system)
4. Check all connections with soap and water solution.
Tighten; or remove and apply pipe dope or pipe tape to
the threads, then reassemble.
5. Piston ring worn 5. Replace piston and cylinder.
6. Broken valve (in pump) 6. Replace valve.
7. Tank leaks 7. Check tank for leaks with soap and water solution. If
leak is detected, tank must be replaced with genuine
replacement part.
8. Defective pressure switch 8. Replace switch.
9
HU500000, HU502000
www.chpower.com
Troubleshooting Chart (Continued)
Symptom Possible Cause(s) Corrective Action
Excessive moisture in
discharge air
1. Excessive water in tank 1. Drain tank.
2. High humidity 2. Move to area of less humidity; use air line filter.
Knocks, rattles, and/or
excessive vibration
1. Loose mounting bolts 1. Tighten bolts.
2. Tank not level 2. Use sturdy wedge / object to bring tank to level position.
3. Cylinder or piston is worn/
scored
3. Replace or repair as necessary.
Compressor runs
continuously and safety
valve opens as pressure
rises
1. Defective pressure switch 1. Replace switch.
2. Defective safety valve 2. Replace safety valve with genuine replacement part.
Air leaking from
unloader valve on
pressure switch
1. Check valve stuck in an open
position
1. Replace check valve.
2. Unloader valve stuck in open
position
2. Replace unloader valve.
Do not disassemble check valve with
air pressure in tank; bleed tank.
10
Operating Instructions
www.chpower.com
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: One Year.
2. WHO GIVES THIS WARRANTY (WARRANTOR):
Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400.
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld
compressor.
4. WHAT PRODUCT IS COVERED BY THIS WARRANTY: This Campbell Hausfeld air compressor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects due to material and workmanship with the exceptions noted below.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY:
A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM THE DATE OF
ORIGINAL PURCHASE AS STATED IN THE DURATION. If this compressor is used for commercial, industrial or rental purposes, the warranty
will apply for ninety (90) days from the date of purchase. Some States do not allow limitations on how long an implied warranty lasts, so
the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE,
OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with instructions
provided in the owner’s manual(s) supplied with compressor.
D. Pre-delivery service, e.g. assembly, oil or lubricants, and adjustment.
E. Items or service that are normally required to maintain the product, e.g. lubricants, filters and gaskets, etc.
F. Gasoline engines and components are expressly excluded from coverage under this limited warranty. The Purchaser must comply with
the warranty given by the engine manufacturer which is supplied with the product.
G. Additional items not covered under this warranty:
1. All Compressors
a. Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance
with installation and operation guidelines or damaged by contact with tools or surroundings.
b. Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants.
c. Cosmetic defects that do not interfere with compressor functionality.
d. Electric motors, check valves and pressure switches.
e. Drain cocks.
f. Damage due to incorrect voltage or improper wiring.
g. Other items not listed but considered general wear parts.
h. Pressure switches, air governors and safety valves modified from factory settings.
2. Lubricated Compressors
a. Pump wear or valve damage caused by using oil not specified.
b. Pump wear or valve damage caused by any oil contamination or by failure to follow proper oil maintenance guidelines.
3. Belt Drive / Direct Drive / Gas Driven Compressors
a. Belts.
b. Ring wear or valve damage from inadequate filter maintenance.
c. Manually adjusted load/unload and throttle control devices.
7. ADDITIONAL WARRANTY LIMITATIONS FOR UNITS WITH THE 10 YEAR "TOUGH TANK" GUARANTEE.
A. WHAT IS COVERED BY THE 10 YEAR "TOUGH TANK" GUARANTEE:
1. At the warrantor’s option, replace any tank or product which is found to have a manufacturer’s defect in the tank for ten (10) years
from the date of purchase by the original purchaser and subject to the exclusions below.
B. WHAT IS NOT COVERED BY THE 10 YEAR "TOUGH TANK" GUARANTEE:
1. The compressor and all parts other than the tank, consult the written warranty issued for your specific compressor model.
2. Defects in the tank not related to a manufacture's defect including but not limited to:
a. Failures due to rust.
b. Failures due to corrosive environments.
c. Failures due to neglect or abuse.
3. Any tank that has been altered in any way.
4. Any tank used for anything other than its original intended purpose.
5. Any unit that has been fitted with any non-OEM parts.
6. Labor to replace a defective tank.
8 RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, compressor or component which is
defective, has malfunctioned and/or failed to conform within the duration of the specific warranty period.
9. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
A. Provide dated proof of purchase and maintenance records.
B. Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service Center. Freight
costs, if any, must be borne by the purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
10. WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and
serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts.
This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have other rights which
vary from State to State or country to country.
Notes / Notas
Operating Instructions Instructions d’Utilisation Manual de Instrucciones
31
HU500000, HU502000
Service Record
Enregistrement d’entretien
Registro de Servicios
32
Operating Instructions Instructions d’Utilisation Manual de Instrucciones
Date Maintenance performed Repair components required
Date Entretien exécuté Éléments de remplacement requis
Fecha Maintenimiento efectuado Componentes de reparación necesarios
HU500000, HU502000
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Campbell Hausfeld HU502000 User manual

Category
Air compressors
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI