Tripp Lite SRCOOLNET Owner's manual

Type
Owner's manual
Installation and
Quick Start Guide
SNMP/Web Management
Accessory
Model: SRCOOLNET
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Read this manual carefully before installation. A separate User's Guide (PDF
format) is included on the CD-ROM bundled with SRCOOLNET. Refer to the
User's Guide for additional information about configuration and operation.
Installation 2
Features 12
Tech Support 13
Warranty 13
Español 15
Français 29
Русский 43
WARRANTY
REGISTRATION
Register online today for a
chance to win a FREE Tripp Lite
product! www.tripplite.com/warranty
13-08-187 93-32CA.indb 1 9/27/2013 9:25:19 AM
2
The SRCOOLNET allows the user to communicate with and control Tripp Lite’s
SRCOOL12K and SRXCOOL12K spot coolers as manageable devices on a network
accessible via a Web Browser, Network Management Station or Telnet.
1 - Preparation
1-1
Confirm Package Contents: In addition to this manual, your package should
include the following:
• Configurationcable(73-1025)
• CD-ROMcontainingadditionaldocumentation
•100-240VACAdapterwithNEMA5-15PandCEE7/7Plug
•ENVIROSENSEModule
•ENVIROSENSEUserManual
• VelcroStrips
• RubberMountingFeet
1-2
Locate MAC Address: The12-digitMACaddress(000667xxxxxx)islocatedon
the underside of the SRCOOLNET.
1-3
Determine Network Installation Method: Ifyournetwork'sDHCPserverwill
assignadynamicIPaddresstotheSRCOOLNETautomatically,proceedto
2 - Dynamic IP Address Assignment.IfyouwillassignastaticIPaddressto
the SRCOOLNET manually, proceed to 3 - Static IP Address Assignment. If you
are uncertain which method to use, contact your network administrator for
assistance before continuing the installation process.
Installation
13-08-187 93-32CA.indb 2 9/27/2013 9:25:19 AM
3
Installation
2 - Dynamic IP Address Assignment
2-1
Connect the SRCOOLNET to the SRCOOL12K or SRXCOOL12K: Usingthe
dedicated connector
A
, connect the SRCOOLNET to the communication port on
thesideofthespotcooler(SeeFigure1onPage5).
2-2
Connect SRCOOLNET to Power: ConnecttheACAdapter
B
to the SRCOOLNET
viatheportlabeled“DCPower”
C
andplugtheotherendintoanACpower
source(SeeFigure1onPage5).
Note: The SRCOOLNET must be plugged into a power source protected by a
UPS or Inverter/Charger in order to maintain communications during a power
outage.
2-3
Connect SRCOOLNET to Network: Connect a standard Ethernet patch cable to
theRJ45EthernetportontheSRCOOLNET. Note: This port does not support
PoE (Power over Ethernet) applications. The SRCOOLNET will attempt to obtain
anIPaddressviaDHCP.Thismaytakeaslongasseveralminutes,dependingon
your network environment.
2-4
Discover IP Address: ContactyournetworkadministratortodeterminewhichIP
addresshasbeenassignedtotheSRCOOLNETbytheDHCPserver.Thecardcan
beidentifiedontheDHCPserverbyreferringtoitsMACaddress(seeStep
1-2
).
Youmaywishtorequestalong-termleaseperiodfortheIPaddress,depending
onyourapplication.AfteryouhavediscoveredtheIPaddress,proceedto
4 - Test and Configure. Note: The DHCP address is also displayed during boot-
up when connected to a computer through the configuration cable and a
terminal emulation program.
13-08-187 93-32CA.indb 3 9/27/2013 9:25:19 AM
4
Installation
3 - Static IP Address Assignment/Terminal Menu
Configuration Settings
3-1
Determine IP Information: BeforeassigningastaticIPaddress,you'llneedto
knowtheIPaddress,gatewayaddressandsubnetmask.Ifyoudonothavethis
information, contact your network administrator for assistance.
3-2
Configure Terminal Emulation Program: OpenaVT100-compatibleterminal
emulationprogram(suchastheHyperTerminalprogrambundledwithMicrosoft
®
Windows
®
)onacomputerwithanavailableDB9
serialport.Anotebookcomputermaybethe
most convenient choice. Set the terminal
emulation program to use the COM port
1
that
correspondstotheDB9serialport.Specifythe
parameters
2
required to communicate with the
SRCOOLNET terminal interface:
If the terminal emulation program supports multiple emulation modes, you may
alsoneedtospecifyVT100emulation
3
.
Bits per second: 9600
Databits: 8
Parity: None
Stop bits: 1
Flow control: None
1 2 3
13-08-187 93-32CA.indb 4 9/27/2013 9:25:20 AM
5
Installation
3-3
Connect SRCOOLNET to Computer: Usetheincludedmini-DINtoDB9
configurationcable(partnumber73-1025)toconnecttheSRCOOLNETtothe
computer. The circular connector
D
at one end of the cable attaches to the
8-pinmini-DINserialport(labeledCONFIG)
E
ontheSRCOOLNET(Alignthe
connectorcarefullytoavoiddamagingthepins).TheDB9connector
F
at the
other end of the cable connects to the computer’s serial port
G
.
Note: Self-adhesive Velcro strips are included for mounting the SRCOOLNET to the
side of the A/C unit. As an alternative, the included rubber feet can be used if the
SRCOOLNET will be freestanding.
3-4
Connect SRCOOLNET to Network: Connect a standard Ethernet patch cable to
theRJ45EthernetportontheSRCOOLNET.Note: This port does not support
PoE (Power over Ethernet) applications.
3-5
Connect the SRCOOLNET to the SRCOOL12K or SRXCOOL12K: Usingthe
dedicated connector
A
, connect the SRCOOLNET to the communication port on
thesideofthespotcooler(RefertoFigure1).
3-6
Connect SRCOOLNET to Power: (RefertoFigure1).ConnecttheACAdapter
B
totheSRCOOLNETviatheportlabeled“DCPower”
C
and plug the other
endintoanACpowersource.
Note: The SRCOOLNET must be plugged into a power source protected by a UPS
or Inverter/Charger in order to maintain communications during a power outage.
Figure 1
A
B
D
G
C
E
F
13-08-187 93-32CA.indb 5 9/27/2013 9:25:20 AM
6
Installation
This card's hostname [ ]?
This card's domain [ ]?
Obtain IP settings automatically using
DHCP for Ethernet interface? [Y]
IP address? [10.2.0.98]
Subnet mask? [255.0.0.0]
Gateway address? [10.0.0.1]
DNS server 1? [10.0.0.5]
DNS server 2? [10.2.0.10]
This cards host name? [cornflakes]
This cards domain? [tlsoftwaredev.local]
SNMP Settings
Enable SNMP Community 0 [Y]? y
Choose a community privilege level:
0 - noAccess
1 - v1UserReadOnly
2 - v1UserReadWrite
3 - v2cUserReadOnly
4 - v2cUserReadWrite
Privilege Level [4]:
Community Name [tripplite]:
Allowable Address Range : [0.0.0.0]?
Allowable Address Mask : [0.0.0.0]?
Enable SNMP Community 1 [N]? n
Enable SNMP Community 2 [N]? n
Enable SNMP Community 3 [N]? n
Note: Default SNMP access is:
Community 0 enable with v2 read only
community public
Community 1 enable with v2 read/write
community tripplite
3-7
Configure SRCOOLNET in Terminal Mode: Note: The SRCOOLNET must be
reinitialized by pressing the reset button (located between the "Link" and "Status"
descriptions under the RJ45 port on the SRCOOLNET), for 3 seconds. Afterthe
brief message shown below, an initialization page should appear in the terminal
emulationprogram.Pressanykeyonthekeyboardwithin5secondstochange
theSRCOOLNET'ssettings(Ifthe5-secondperiodhaselapsed,youcan
reinitializetheSRCOOLNET).
Note: The following message will appear in the terminal startup menu:
IAM:Got AUTO-CONFIGURED IPv6 address FE80::4200:FF:FE01:8 on interface eth0:3
IPv6 is not currently supported. Tripp Lite is working on IPv6 for a future release.
FollowthesequenceofresponsesbelowinordertoassignanIPaddresstothe
SRCOOLNET.ThedefaultterminalmodepasswordisTrippLite.SampleIPsettings
areshown-supplyyourownIPinformationwhenyouconfigureyourSRCOOLNET.
13-08-187 93-32CA.indb 6 9/27/2013 9:25:21 AM
7
Installation
Additional Settings
AdditionalEthernetSettings:
Enable SNTP? [N]
Enable http? [Y]
Port number? [80]
Enable https? [N]
Port number? [443]
Enable telnet? [Y]
Port number? [23]
Enable ssh? [Y]
Port number? [22]
Hardware Parameters:
Would you like to update the RTC date/time in GMT? [N]
Time Zone (0 is GMT, -6 is CST) :
Time Zone Offsets Supported
Western Hemisphere Eastern Hemisphere
Hour
Off-Set
Location
Hour
Off-Set Location
0 Greenwich,England 1 MidEurope/Africa
-1 SEGreenland 2 EEurope,ECentralAfrica
-2 AtlanticOcean 3 Moscow,Mid-East,EAfrica
-3 GreenlandTime 4 NW Caspian Sea
-4 AtlanticTime 5 UralMountains,Russia
-5 Eastern Standard Time 6 Almaty(AlmaATA),Russia
-6 Central Standard Time 7 W Mongolia
-7 Mountain Standard Time 8 China
-8 PacicStandardTime 9 Japan
-9 AlaskaTime 10 EasternRussia,Sydney,Australia
-10 Hawaii 11 Kamchatskiy, E Russia
-11 PacicOcean
+/-12 InternationalDateLine
Do you wish to configure the advanced settings [y/n]? [Y]
ThisinterfacemusthaveauniqueMACaddress.
Ethernet MAC Address? [00:06:67:01:00:08]
13-08-187 93-32CA.indb 7 9/27/2013 9:25:21 AM
8
Installation
DO NOT MODIFY UNLESS DIRECTED BY YOUR ADMINISTRATOR
Do you want to completely erase the file system? [N]
DO NOT MODIFY UNLESS DIRECTED BY TRIPP LITE TECHNICAL SUPPORT
Default Ethernet setting (0=Auto, 1=10 Half, 2=10 Full, 3=100 Half, 4=100
Full)? [Auto]
DO NOT MODIFY UNLESS DIRECTED BY YOUR ADMINISTRATOR
Youcanalsochangetherootpassword,real-timeclockandothersettings.
Tripp Lite recommends against changing the default settings unless you are an
advanceduserwithaspecificpurpose.Afteryouhavefinishedenteringsettings,
theSRCOOLNETwillsavechangestomemoryandreboot(thismaytakeseveral
minutes).AftertheSRCOOLNETreboots,theinitializationpageshoulddisplaythe
newstaticIPsettings.
3-8
Remove Configuration Cable: Remove the configuration cable that connects
the SRCOOLNET to the computer.
4 - Test and Configure
4-1
Test Network Connection: AfteranIPaddresshasbeenassignedtothe
SRCOOLNET, try to access it with a Web browser that supports frames, forms
andJava™.OpenaWebbrowseronacomputerconnectedtotheLANandenter
theSRCOOLNET’sIPaddress.Youwillbepromptedforapassword.Theuser
nameislocaladminandthedefaultpasswordislocaladmin.Afteryouenterthe
usernameandpassword,thePowerAlertStatuspagewillappearinthebrowser
window. For more information about configuration and operation of the managed
device,refertotheUser'sGuide,includedontheCD-ROMbundledwiththe
SRCOOLNET.
Note: When using the SRCOOLNET with the SRCOOL12K or SRXCOOL12K, do
not use the cooling unit’s manual control panel.
13-08-187 93-32CA.indb 8 9/27/2013 9:25:21 AM
9
Installation
5 - Using EnviroSense
®
for Remote Temperature Setpoint
SRCOOLNET supports the use of the included EnviroSense environmental sensor to
control the SRCOOL12K setpoint instead of the temperature sensor in the return
airstream. This helps ensure that supply air to important equipment is at or below a
target temperature in cases where SRCOOL12K is indirectly supplying cold air to that
equipment.
5-1
Important Considerations When Using Remote Temperature Setpoint Mode
It is important to keep the following considerations in mind when using the Remote
Temperature Setpoint feature of SRCOOLNET:
1
The temperature being used for controlling the status of the attached cooling
device is the EnviroSense sensor, NOT the return air temperature. The return air
temperature may be higher or lower than the temperature Envirosense is
reporting.
2
The setpoint displayed on the attached cooling device display panel will probably
NOT match the Remote Setpoint Temperature specified. Typically the setpoint
temperaturedisplayedonthedevicedisplaypanelwillbetheminimum(when
cooling)ormaximum(whennotcooling)setpointpermissiblebythecoolingunit.
3
If the return air temperature at the air intake of the cooling device is outside the
limits of the cooling device, the Remote Temperature Setpoint mode will be
unable to control the temperature at the Envirosense sensor. For this reason it is
importanttoensurethatthecoolingunitairintaketemperaturebebetween17°C
and30°CfortheRemoteTemperatureSetpointtoworkcorrectly.
4
If the power button on the cooling unit display panel is pressed while in Remote
Temperature Setpoint mode, the mode will be canceled.
13-08-187 93-32CA.indb 9 9/27/2013 9:25:21 AM
10
Installation
5-2
Configuring SRCOOLNET for Remote Setpoint Usage
To use the Remote Temperature Setpoint mode of operation, ensure that the device is
connected to SRCOOLNET and installed
A
.FromtheUserInterface,turnthe
SRCOOL12KunitONandclickthe'Remote'checkboxontheSRCOOLNETuser
interface
B
. Type in the temperature setpoint you wish the SRCOOL12K to target and
press ENTER.
Note: SRCOOLNET not shown to
scale. A self-adhesive Velcro strip is
included for mounting the
ENVIROSENSE.
ENVIROSENSE
MODULE
ENVIROSENSE
MODULE
SRCOOLNET
SRCOOLNET
A
13-08-187 93-32CA.indb 10 9/27/2013 9:25:21 AM
11
Installation
SRCOOL12K will now begin cooling when the temperature reading at EnviroSense
equalsorexceedsthesetpointvalueyouentered.Whenthetemperaturefallsbelow
thissetpoint,theunitwillstopcooling.Ifthe'AlwaysOn'checkboxischecked,the
fanswillremainrunningwhentheunitstopscooling.Ifthe'AlwaysOn'checkboxis
unchecked,thefanswillshutoffandtheSRCOOL12Kdisplaywillextinguish.Once
the temperature reaches the setpoint again, the unit will restart and begin cooling
until the temperature reported by EnviroSense returns below the setpoint. This cycle
will continue indefinitely until you select STOP from the SRCOOLNET user interface.
B
13-08-187 93-32CA.indb 11 9/27/2013 9:25:22 AM
12
Features
PS/2 Port: UsethisporttoconnecttheTrippLiteENVIROSENSE
environmental sensor to provide remote temperature/humidity
monitoring and a dry contact interface to control and monitor
alarm, security and telecom devices. Note: Do not connect a
keyboard or mouse to this port.
Mini-DIN Serial Port: Usethisporttoprovideadirectterminal
connection to a computer with a terminal emulation program.
Aconfigurationcable(partnumber73-1025)isincludedwiththe
SRCOOLNET. If you need to order a replacement cable, visit
www.tripplite.com/support.
Ethernet Port: UsethisRJ45jacktoconnecttheSRCOOLNETto
thenetworkwithastandardEthernetpatchcable.TheLinkLED
C1
andStatusLED
C2
indicate several operating conditions, as shown
inthetablebelow.DoesnotsupportPoE(PowerOverEthernet)
applications.
SRCOOLNET Operating Conditions
C1
Link LED Color
Off No Network Connection
FlashingAmber 100MbpsNetworkConnection
FlashingGreen 10MbpsNetworkConnection
C2
Status LED Color
Off SRCOOLNET Not Initialized
SteadyGreen SRCOOLNET Initialized and Operational
FlashingAmber Error-SRCOOLNETNotInitialized
Reset Button: Presstheresetbuttonfor3secondstorebootthe
SRCOOLNET. Rebooting the SRCOOLNET will not erase network
settingsorinterruptACpower.Note: The recessed button is located
just beneath the Ethernet port. Use a pin, paper clip, or pointed
tool to access the button.
C1
C2
RESET
13-08-187 93-32CA.indb 12 9/27/2013 9:25:22 AM
13
Technical Support can be found at: www.tripplite.com/support
Features
Warranty and Warranty Registration
Technical Support
DC Power Jack: ThisportisusedtoconnecttheACAdapter(outputplug)tosupply
power to the SRCOOLNET.
SRCOOLNET Interface Connector: This dedicated connector is used to connect the
SRCOOLNET to the SRCOOL12K or SRXCOOL12K and features a locking ring for
securing the connection.
AC Power Adapter: UsedtoprovidepowertotheSRCOOLNET.Note: Plug into an AC
power source supported by a UPS or Inverter/Charger in order to maintain
communications during a power outage.
LIMITED WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects
inmaterialandworkmanshipforaperiodof2years(exceptinternalUPSsystembatteriesoutsideUSAandCanada,
1year)fromthedateofinitialpurchase.Iftheproductshouldprovedefectiveinmaterialorworkmanshipwithin
that period, Seller will repair or replace the product, in its sole discretion. Service under this Warranty can only be
obtainedbyyourdeliveringorshippingtheproduct(withallshippingordeliverychargesprepaid)to:TrippLite,1111
W.35th Street,Chicago, IL60609,USA.Seller willpayreturn shippingcharges.Visit www.tripplite.com/support
before sending any equipment back for repair.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE,
ABUSEOR NEGLECT. SELLERMAKESNO EXPRESS WARRANTIESOTHER THANTHE WARRANTYEXPRESSLYSET
FORTHHEREIN.EXCEPTTOTHEEXTENTPROHIBITEDBYAPPLICABLELAW,ALLIMPLIEDWARRANTIES,INCLUDING
ALLWARRANTIESOFMERCHANTABILITYORFITNESS,ARELIMITEDINDURATIONTOTHEWARRANTYPERIODSET
FORTHABOVE;AND THISWARRANTYEXPRESSLYEXCLUDESALL INCIDENTALANDCONSEQUENTIAL DAMAGES.
(Somestatesdo notallowlimitations onhowlongan impliedwarrantylasts, andsomestatesdo notallowthe
exclusionorlimitationofincidentalorconsequentialdamages,sotheabovelimitationsorexclusionsmaynotapply
toyou.ThisWarrantygivesyouspecificlegalrights,andyoumayhaveotherrightswhichvaryfromjurisdictionto
jurisdiction).
WARNING:Theindividualusershouldtakecaretodeterminepriortousewhetherthisdeviceissuitable,adequate
orsafefortheuseintended.Sinceindividualapplicationsaresubjecttogreatvariation,themanufacturermakesno
representation or warranty as to the suitability or fitness of these devices for any specific application.
NotcompatiblewithPoE(PoweroverEthernet)applications.
13-08-187 93-32CA.indb 13 9/27/2013 9:25:22 AM
14
Warranty and Warranty Registration
WARRANTY REGISTRATION
Visitwww.tripplite.com/warrantytodaytoregisterthewarrantyforyournewTrippLiteproduct.You'llbeautomatically
entered into a drawing for a chance to win a FREE Tripp Lite product!*
*Nopurchasenecessary.Voidwhereprohibited.Somerestrictionsapply.Seewebsitefordetails.
CAUTION: Use of this equipment in life support applications where failure of this equipment can reasonably be
expectedtocausethefailureofthelifesupportequipmentortosignificantlyaffectitssafetyoreffectivenessisnot
recommended.Donotusethis equipmentin thepresenceofaflammableanestheticmixture withair,oxygenor
nitrousoxide.
WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union)
Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when
customers buy new electrical and electronic equipment from Tripp Lite they are entitled to:
•Sendoldequipmentforrecyclingonaone-for-one,like-for-likebasis(thisvariesdependingonthecountry)
•Sendthenewequipmentbackforrecyclingwhenthisultimatelybecomeswaste
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned
a unique series number. The series number can be found on the product nameplate label, along with all required
approval markings and information. When requesting compliance information for this product, always refer to the
series number. The series number should not be confused with the marking name or model number of the product.
TrippLitehasapolicyofcontinuousimprovement.Productspecificationsaresubjecttochangewithoutnotice.
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
13-08-187 93-32CA.indb 14 9/27/2013 9:25:22 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Tripp Lite SRCOOLNET Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI