American Standard 6032.STLH User manual

  • Hello! I am an AI chatbot trained to assist you with the American Standard 6032.STLH User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation
Instructions
751817-100 Rev. Q
Certified to comply with ANSI Z124.2.
Observe local plumbing and building codes.
SPECIFICATIONS:
Product No.
Size:
Product No.
Size:
Product No.
Size:
NOTE: Read instructions completely before proceeding with installation.
3636.ST
36" x 36-3/16"
(914 x 919mm)
3636.NEO
60-1/8" x 34-1/8"
(1527 x 867mm)
1
4242.ST
6034.ST
3838.NEO 4242.NEO
42-1/8" x 42-1/8"
(1070 x 1070mm)
4834.ST
48-1/8" x 34-1/4"
(1222 x 870mm)
36-1/4" x 36-1/8"
(921 x 918mm)
4832.ST
48" x 32"
(1219 x 813mm)
6032.STRH
6032.STLH
60" x 32"
(1524 x 813mm)
60" x 32"
(1524 x 813mm)
38-1/8" x 38-1/16"
(968 x 967mm)
42-1/4" x 42-1/8"
(1073 x 1070mm)
34-1/4"
(870mm)
16-3/4"
(425mm)
24-1/16"
(611mm)
48-1/8"
(1222mm)
4834.ST
6034.ST
3838.NEO
4242.NEO
38-1/16"
(967mm)
38-1/8"
(968mm)
12-1/2"
(318mm)
12-1/2"
(318mm)
19-7/8"
(505mm)
25-3/4"
(654mm)
19-7/8"
(505mm)
42-1/8"
(1070mm)
12-1/2"
(318mm)
12-1/2"
(318mm)
42-1/4"
(1073mm)
24"
(610mm)
25-5/8"
(651mm)
24"
(610mm)
3636.NEO
918mm
(36-1/8")
921mm
(36-1/4")
318mm
(12-1/2")
318mm
(12-1/2")
17-7/8"
(454mm)
656mm
(25-13/16")
454mm
(17-7/8")
34-1/8"
(867mm)
16-3/4"
(425mm)
30"
(762mm)
60-1/8"
1527mm
FRONT
32"
(813mm)
16"
(406mm)
24"
(610mm)
48"
(1219mm)
FRONT
FRONT
32"
(813mm)
32"
(813mm)
16"
(406mm)
16"
(406mm)
8"
(203mm)
60"
(1524mm)
FRONT
3232.ST
32"
(813mm)
16"
(406mm)
32"
(813mm)
15-3/8"
(391mm)
FRONT
4242.ST
4832.ST
6032.STLH
6032.STRH
42-1/8"
(1070mm)
21"
(533mm)
42-1/8"
(1070mm)
20-3/4"
(527mm)
FRONT
3232.ST
32" x 32"
(813 x 813mm)
3636.ST
36-3/16"
(919mm)
18"
(457mm)
36"
(914mm)
17-3/4"
(451mm)
FRONT
Thank you for selecting American Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully
before you begin.
ACRYLIC SHOWER BASE
MODELS: 3232.ST, 3636.ST, 4242.ST, 4832.ST, 4834.ST, 6032.STLH,
6032.STRH, 6034.ST, 3636 NEO, 3838.NEO, 4242.NEO
For alcove (.ST models) installation only:
The opening dimensions should be 1/8" larger than dimensions shown.
© AS America, Inc. 2008
751817-100 Rev. Q
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
CLEANING AND MAINTENANCE
D
C
E
F
G
H
DRAIN
ASSEMBLY
Strainer
Drain
Body
Shower
Base
Silicone
Sealant
Rubber
Gasket
Fiber
Gasket
Locking
Nut
Rubber
Caulking
Gasket
Lift and lower base over center
of drain pipe and set into place
Base Flange
Drywall
Screw
Bracket
Stud
Shower
Base
Shower
Base
Splash
Lip
Flange
Bracket
Tile
Adhesive
Waterproof
Drywall
Tile
Stud
Caulk
Your American Standard shower base is designed to last indefinitely
with reasonable care and maintenance.
The high-gloss acrylic surface is resistant to impact and retains its luster
with proper care and maintenance. An integral, slip-resistant surface is
incorporated for user safety.
General Cleaning: Do not use abrasive cleaners; a mixture of warm
water and a mild liquid detergent is adequate for most cleaning. Strong
detergents formulated for use on tile or porcelain-enamel surfaces
should be avoided.
Caution: Do not allow liquid detergent containers to remain on base
surfaces for more than a few moments. Do not use Lestoil, Windex, Mr.
Clean, Dow Disinfectant (spray or concentrate), or Lysol Basin, Tub and
Tile Cleaner. Do not allow nail polish remover, dry cleaning fluid, acetone,
paint remover, or other solvents to contact acrylic surface.
Level
Level
Level base in two directions.
51x102 mm
(2x4) Stud Wall
Waterproof
Drywall
13mm (1/2")
minimum
Bedding Material Area
3 mm
(1/8)
127 mm (5)
51 mm (2)
PVC Pipe
159mm
(6-5/8)
Bedding
Material
No Bedding
Under
Apron
Before installing drain into
the shower base, remove
strainer (see Fig. C). This
will be installed after
shower base is in its final
position. Install the drain to
the shower base as shown
in Fig. D. Use silicone
sealant between drain
body and shower base.
Secure the base to the studs as shown, using the
screws and the brackets provided. See Fig. G.
Note: Allow the bedding material to completely
harden before applying weight to the bottom of
the shower base.
Draw a line 6-5/8" (159mm) from the
sub-floor on to the studs at each
side of the opening. Using this line
and a level, mark the remaining
studs. (See Figs. A & B.) This will be
the installed height of the shower
base. Mix the low-shrink bedding
material (grout, mortar, plaster, etc.).
Concrete is not recommended.
Apply enough bedding material to
support the entire bottom of the
shower base. The bedding material
must not be used under the apron
(front edge).
1
SHOWER BASE
3636.NEO
3838.NEO
4242.NEO
3232.ST
4834.ST
6034.ST
3636.ST
4242.ST
4832.ST
6032.STRH/LH*
5/16" ± 1/16"
3/8" ± 1/16"
5/16" ± 1/16"
3/8" ± 1/16"
1/4" ± 1/16"
1/4" ± 1/16"
1/4" ± 1/16"
5/16" ± 1/16"
1/2" ± 1/16"
1/2" ± 1/16"
WASTE PIPE HEIGHT
2
3
4
5
6
A
51 mm (2)
PVC Waste Pipe
127mmx127mm
(5x5) Opening
(See Product Chart for Drain Location)
C/L
C/L
3636.NEO, 3838.NEO, 4242.NEO
90° 90°
6-5/8
6-5/8
Insure the floor and stud walls are square and plumb. Provide a 5" x 5" (127mm x
127mm) opening in the floor for the drain (see Figs. A & B). The drain plug
accom-modates a 2" (51mm) PVC waste pipe. The waste pipe should extend above
the surface of the sub-floor, refer to chart on page 2 for the required dimensions.
See product drawings on this page for the specified drain locations.
B
3232.ST, 3636.ST, 4242ST, 6034.ST, 4834.ST, 4832.ST
90°
90°
51 mm (2)
PVC Waste Pipe
127mmx127mm
(5x5) Opening
C/L
(See Product Chart for Drain Location)
6-5/8
Tape over the strainer to protect the finish
and prevent construction debris from
entering the drain.
Finish installation as shown in Figure H.
After the bedding material has been poured and
before it sets, lower the shower base into position
with the drain assembly sliding over the waste pipe
as shown in Fig. E. It will be necessary to "rock" the
shower base until the top of the tile flange aligns
with the lines drawn in Step 3 on the stud walls.
Make certain the apron is contacting the rough floor
along the entire length of the shower base. Insure
that the base is level in two directions (see Fig. F).
Snap strainer back into place and check for proper
drainage.
Note: Variations in
levelness of the subfloor
may require adjustment
of waste pipe height.
* For 6032.STRH and
6032.STLH, see drawing
for proper location of
5" x 5" drain cut-out.
/