Lincoln Manufacturing Series 1000 User manual

Type
User manual

This manual is also suitable for

1000serviceexp REV: 1/5/07
SERVICE MANUAL
(INTERNATIONAL)
IMPINGER CONVEYOR OVENS
MODEL SERIES 1000 & 1200
Lincoln Foodservice Products, LLC
1111 North Hadley Road
Fort Wayne, Indiana 46804
United States of America
Phone : (800) 374-3004
U.S. Fax: (888) 790-8193 • Int’l Fax: (260) 436-0735
Technical Service Hot Line
(800) 678-9511
www.lincolnfp.com
Impinger I -–1000 Series Service Manual - International 2
TABLE OF CONTENTS
TABLE OF CONTENTS..............................................................................................................................................2
SEQUENCE OF OPERATIONS 1002/1003...............................................................................................................3
SEQUENCE OF OPERATIONS 1106........................................................................................................................4
SEQUENCE OF OPERATIONS 1028 / 1029 / 1228 / 1229 ......................................................................................5
SEQUENCE OF OPERATIONS 1030........................................................................................................................6
SEQUENCE OF OPERTIONS 1032 ..........................................................................................................................7
SEQUENCE OF OPERATIONS / 1033, 1034, 1046, 1047 .......................................................................................8
SEQUENCE OF OPERATIONS 1042 / 1043 / 1242 / 1243 ....................................................................................10
SCHEMATIC / 1002, 1003 .......................................................................................................................................12
SCHEMATIC / 1006 TO SERIAL NUMBERS Q14279.............................................................................................13
SCHEMATIC / 1028, 1029, S/N Q19071 & BELOW................................................................................................14
SCHEMATIC / 1028, 1029, S/N Q19078 & ABOVE.................................................................................................15
SCHEMATIC / 1030, TO S/N Q17170......................................................................................................................16
SCHEMATIC / 1030, S/N Q17171 & ABOVE...........................................................................................................17
SCHEMATIC / 1032. S/N Q19077 & BELOW ..........................................................................................................18
SCHEMATIC / 1032, S/N Q19078 & ABOVE...........................................................................................................19
SCHEMATIC / 1033, 1034, 1046, 1047 ...................................................................................................................20
SCHEMATIC / 1042, 1043, S/N Q14279 & BELOW................................................................................................21
SCHEMATIC / 1042, 1043, S/N Q14280 & ABOVE.................................................................................................22
SCHEMATIC / 1228. 1229, S/N Q14790 & BELOW................................................................................................23
SCHEMATIC / 1228, 1229, S/N Q14791 & ABOVE.................................................................................................24
SCHEMATIC / 1242, 1243 .......................................................................................................................................25
TROUBLESHOOTING GUIDE 1000 & 1200 / GAS OVENS ..................................................................................26
TROUBLESHOOTING GUIDE 1000 & 1200 SERIES / ELECTRIC OVENS...........................................................39
TROUBLESHOOTING / GAS OVENS 1033, 1034, 1046, 1047..............................................................................46
REMOVAL, INSTALLATION & ADJUSTMENTS .....................................................................................................53
MODEL SERIES 1000 &1200...............................................................................................................................53
PARTS / MODEL SERIES 1000 & 1200 - GENERAL..............................................................................................80
BLOW UP / 1000, 1200 – GENERAL.......................................................................................................................81
PARTS / MODEL 1002-1003 , S/N 2584 TO 4389 ..................................................................................................82
BLOW UP / 1002, 1003 – S/N 2584 to 4389............................................................................................................83
PARTS / MODEL 1002-1003, S/N 4390 & UP.........................................................................................................84
BLOW UP / 1002, 1003 – S/N 4390 & ABOVE........................................................................................................85
PARTS / MODEL 1006.............................................................................................................................................86
BLOW UP / 1006 ......................................................................................................................................................87
PARTS / 1028-1029-1032 ........................................................................................................................................88
BLOW UP / 1028, 1029, 1032 ..................................................................................................................................89
PARTS/ MODEL 1030..............................................................................................................................................90
BLOW UP / 1030 ......................................................................................................................................................91
PARTS / 1042, 1043.................................................................................................................................................92
BLOW-UP / 1042, 1043............................................................................................................................................93
PARTS / 1033, 1034, 1046, 1047.............................................................................................................................94
BLOW-UP / 1033, 1034, 1046, 1047........................................................................................................................95
PARTS / 1228-1229..................................................................................................................................................96
BLOW UP / 1228, 1229 ............................................................................................................................................97
PARTS / 1242, 1243.................................................................................................................................................98
BLOW - UP / 1242, 1243..........................................................................................................................................99
PARTS / OVEN BACK - GAS.................................................................................................................................100
BLOW UP / OVEN BACK – GAS ...........................................................................................................................101
PARTS / OVEN BACK- ELECTRIC........................................................................................................................102
BLOW UP / OVEN BACK – ELECTRIC .................................................................................................................103
PARTS / CONVEYOR MOTOR ASSEMBLY S/N 4390 & ABOVE ........................................................................104
BLOW UP / CONVEYOR MOTOR ASSEMBLY S/N 4390 & ABOVE ...................................................................105
PARTS / SERIES 1000 – CONVEYOR..................................................................................................................106
BLOW UP / SERIES 1000 CONVEYOR ................................................................................................................107
PARTS / SERIES 1200 - CONVEYOR CONTROL................................................................................................108
BLOW UP / SERIES 1200 – CONVEYOR CONTROL ..........................................................................................109
PARTS / SERIES 1200 – CONVEYOR..................................................................................................................110
BLOW UP / SERIES 1200 – CONVEYOR .............................................................................................................111
Impinger I -–1000 Series Service Manual - International 3
SEQUENCE OF OPERATIONS 1002/1003
MODEL 1002 - 240VAC - 50HZ - NATURAL GAS
MODEL 1003 - 240VAC - 50HZ - L.P. GAS
POWER SUPPLY Electrical Power to be supplied to the Oven by a three conductor service.
Black conductor is Hot
Red conductor is Neutral
Green conductor is Ground
CONTROL BOX When the temperature in the Control Box reaches 120°F +
AUTO COOL DOWN 3°, the Cooling Fan Thermostat will switch power to the Control Box Cooling Fan.
The Thermostat will interrupt power to the Cooling Fan when the Control Box
temperature falls to 100°F + 3°.
MAIN FAN CIRCUIT Electrical power is permanently supplied to the normally open contacts of the Double
Pole Main Fan Relay, the Cooling Fan Thermostat, the normally open Double Pole
Main Fan Switch, and the normally open Cool Down Thermostat (thermostat closes
at 160°F and opens at140°F). Closing the Main Fan Switch supplies 240 VAC
through a 3A Fuse to the primary of the control circuit Step down Transformer. The
Transformer steps the voltage down to 120 VAC for the control circuit. 120 VAC is
supplied to the coil of the Double Pole Main Fan Relay. The coil of the relay is
energized. The normally open contacts now close, energizing the Main Fan Motor
through one 10A Fuse. Closing the Fan Switch also supplies power to the Cooling
Fan, Hour Meter (hour meter discontinued after S/N 3484), the 12.6 VAC
Transformer, the Burner and Conveyor Switches.
BURNER CIRCUIT
Closing the Fan Switch and the normally open Burner Switch supplies 120 VAC
through the Air Pressure Switch, to the normally open contacts of the Burner Motor
Relay, and the primary of the 24 VAC Step Down Transformer. The Transformer
secondary supplies 24 VAC to the Relay Coil (the normally open contacts close
within 30 seconds), and the normally open Centrifugal Switch. When the Relay
contacts close, the Burner Blower Motor is energized. As this motor reaches
approximately 1600 R.P.M., its internal centrifugal switch closes, supplying 24 VAC
to the Gas Control Valve. When the Gas Control Valve is supplied with 24 VAC, the
pilot valve is energized, and the igniter circuit is energized. Ignition should now
occur. After pilot flame is proven, the main gas valve is energized. The Burner
Indicator Light is also energized.
CONVEYOR DRIVE
(S/N 100 to 4389)
Closing the Fan Switch and the normally open Conveyor Switch supplies 120 VAC
through a 3A Fuse, to the Motor Control Board. AC volts are converted to D.C. volts
and are supplied to the Conveyor Motor at board terminals A1 and A2 through a
D.P.D.T. Reversing Switch. Adjustment of the Speed Control Potentiometer (500
ohm, 10 turn) will change resistance at terminals S1, S2, and S3 varying the D.C.
voltage to the motor. The speed of the Conveyor Motor will increase or decrease as
the D.C. voltage from the Motor Control Board increases or decreases respectively
(S/N 4390 and UP)
Closing the fan switch and the conveyor switch supplies 120 VAC to the Motor
Control Board. AC volts are converted to DC volts and are supplied to the Conveyor
Motor at terminals A+ and A-. Adjustment of the Speed Control Potentiometer (5,000
ohm 10 turn) will change resistance at terminals P1, P2, and P3 varying the DC
voltage to the motor. The speed of the conveyor motor will increase or decrease as
the DC voltage from the board increases or decreases respectively. As the motor
turns, it drives both the reducer gear box and the tach. generator which supplies a
voltage to the DC motor control board and is used as a reference for maintaining a
constant conveyor speed
Impinger I -–1000 Series Service Manual - International 4
TIME TEMP DISPLAY The Time/Temp Display is energized when the Fan Switch is closed, supplying 120
VAC to the primary of the 12.6 volt Transformer. The secondary output of the
transformer, normally 13 to 14 VAC (depending on input), with a center tap, is
supplied to terminals 1,2, and 3 of the Time/Temp Display. The center tap is terminal
2. The display works on a balanced input and center tap voltage to each leg must be
1/2 the total reading.
The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach.
coupling) to break the infra-red light beam of the optical switch (mounted on gear
motor) producing electrical pulses that are transmitted to the display. The display
converts these pulses into a read-out of minutes and seconds.
The temperature portion of the display uses a Thermistor Probe to sense oven
temperature. The thermistor outputs a resistance proportional to the oven
temperature. This resistance is then converted by the display into a temperature
reading.
SEQUENCE OF OPERATIONS 1106
MODEL 1006 - 240 VAC - 50HZ - 1 PHASE - NATURAL GAS
POWER SUPPLY Electrical Power to be supplied to the Oven by a three conductor service.
Red conductor is Hot
Black conductor is Neutral
Green conductor is Ground
CONTROL BOX AUTO
COOL DOWN
When the temperature in the Control Box reaches 120°F + 3°, the Cooling Fan
Thermostat will switch power to the Control Box Cooling Fan. The Thermostat will
interrupt power to the Cooling Fan when the Control Box temperature falls to 100°F +
3°.
MAIN FAN CIRCUIT Electrical power is permanently supplied to the normally open contacts of the Double
Pole Main Fan Relay, the Cooling Fan Thermostat, and through a 3A Fuse to the
normally open Double Pole Main Fan Switch, and the normally open Cool Down
Thermostat (thermostat closes at 160°F and opens at 140°F). Closing the Main Fan
Switch supplies 240 VAC to the primary of the control circuit Step Down
Transformer. (The transformer steps the voltage down to 120VAC for the control
circuit) 120 VAC is supplied to the coil of the Main Fan Relay. The coil of the Relay is
energized, the normally open contacts now close, energizing the Main Fan Motor
through one 10A fuse. Closing the Fan Switch also supplies power to the Cooling
Fan, the 12.6 VAC Transformer, the Burner and Conveyor Switches
TRANSFORMER (12.6
VAC)
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to
14 VAC) with a center tap, and supplies power to the Time/Temp Display. The
voltage from each leg of the Transformer's secondary to the center tap should be
one half of the secondary voltage.
BURNER CIRCUIT Closing the Fan Switch and the normally open Burner Switch supplies 120 VAC
through the Air Pressure Switch, to the normally open contacts of the Burner Motor
Relay, and the primary of the 24 VAC Step Down Trans-former. The Transformer
secondary supplies 24 VAC to the coil of the Burner Motor Relay (the normally open
contacts close within 30 seconds), and through the Burner Air Pressure Switch to the
normally open Centrifugal Switch. When the Relay contacts close, the Burner Blower
Motor is energized. As this motor reaches approximately 1600 R.P.M., the Burner Air
Pressure Switch closes, and the motor's internal centrifugal switch closes supplying
24 VAC to the Gas Control Valve. When the Gas Control Valve is supplied with 24
VAC, the pilot valve is energized, and the igniter circuit is energized. Ignition should
now occur. After pilot flame is proven, the main gas valve is energized. The Burner
Indicator Light is also energized.
CONVEYOR DRIVE
(S/N 4390 AND UP)
Closing the fan switch and the normally open conveyor switch supplies 120 VAC to
the Motor Control Board .AC volts are converted to DC volts and are supplied to the
Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control
Potentiometer (5000 ohm 10 turn ) will change resistance at terminals P1, P2, and
P3 varying the DC voltage to the motor. The speed of the conveyor motor will
Impinger I -–1000 Series Service Manual - International 5
increase or decrease as the DC voltage from the board increases or decreases
respectively. As the motor turns, it drives both the reducer gearbox and the Tach.
Generator. The Tach. Generator is a DC voltage generator, which supplies a voltage
to the DC motor control board and is used as a reference for maintaining a constant
conveyor speed.
TlME/TEMP DISPLAY The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120
VAC to the primary of the 12.6 volt Transformer. The secondary output of the
transformer, normally 13 to 14 VAC (depending on input), with a center tap is
supplied to terminals 1,2, and 3 of the Time/Temp Display. The center tap is terminal
2. The display works on a balanced input and center tap voltage to each leg must be
1,2 the total reading.
The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach.
coupling) to break the infra-red light beam of the optical switch (mounted on gear
motor) producing electrical pulses that are transmitted to the display. The display
converts these pulses into a read-out of minutes and seconds.
The temperature portion of the display uses a Thermistor Probe to sense oven
temperature. The thermistor outputs a resistance proportional to the oven
temperature. This resistance is then converted by the display into a temperature
reading.
SEQUENCE OF OPERATIONS 1028 / 1029 / 1228 / 1229
MODEL 1028 - 380Y/220 VAC - 50 HZ - 3 PHASE
MODEL 1029 - 415Y/240 VAC - 50 HZ - 3 PHASE
MODEL 1228 - 380Y/220 VAC - 50 HZ - 3 PHASE - DUAL BELT
MODEL 1229 - 415Y/240 VAC - 50 HZ - 3 PHASE - DUAL BELT
POWER SUPPLY Electrical Power to be supplied to the Oven by a five conductor service.
Black conductor is Hot
Red conductor is Hot
Orange conductor is Hot
White conductor is Dedicated Neutral
Green conductor is Ground
MAIN FAN CIRCUIT Electrical power is permanently supplied through 3, 50A fuses to the normally open
contacts of the Mercury Contactor. Power is also supplied through 1, 10A fuse to the
normally open contact of the Main Fan Relay, through a 1A Fuse to the normally
open Double Pole Main Fan Switch, and to the normally open Cool-Down
Thermostat (thermostat closes at 160°F and opens at 140°F.) Closing the Main Fan
Switch supplies 220 or 240 VAC to the primary of the control circuit Step Down
Transformer. (The transformer steps the voltage down to 120 VAC for the control
circuit.) 120 VAC is supplied to the coil of the Main Fan Relay. The coil of the relay is
energized, the normally open contacts close, energizing the Main Fan Motor. Closing
the Main Fan Switch also supplies power to the 12.6 VAC Transformer, the Control
Box Cooling Fan, and the Heat and Conveyor Switches.
TRANSFORMER (12.6
VAC)
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to
14 VAC) with a center tap, and supplies power to the Time/Temp. Display. The
voltage from each leg of the Transformer's secondary to the center tap should be
one half of the secondary voltage.
HEAT CIRCUIT Closing the Fan Switch and the normally open Heat Switch supplies 120 VAC
through the normally open Air Pressure Switch, and the normally closed Hi-Limit
Thermostat (manually re-settable, opens at 190°F) and, the 3A Fuse, to the L1
terminal of the Temperature Control Board, the coil of the Mercury Contactor, and to
the Heat Indicator Light.
TEMPERATURE
CONTROL
When the Heat Switch is closed, 120 VAC is supplied to the Temperature Control.
The Temperature Control Potentiometer (2.5K ohm) is adjusted to desired
temperature. The Thermocouple will provide varying millivolts to the Temperature
Controller. The Temperature Controller switches the L 2 line of the Contactor coils at
intermittent intervals to maintain desired temperatures.
Impinger I -–1000 Series Service Manual - International 6
CONVEYOR DRIVE
(S/N 100 to 4389)
Closing the Fan Switch and the normally open Conveyor Switch supplies 120 VAC
through a 3A Fuse, to the Motor Control Board. AC volts are converted to D.C. volts
and are supplied to the Conveyor Motor at board terminals A1 and A2 through a
D.P.D.T. Reversing Switch. Adjustment of the Speed Control Potentiometer (500
ohm, 10 turn) will change resistance at terminals S1, S2, and S3 varying the D.C.
voltage to the Conveyor Motor. The speed of the Conveyor Motor will increase or
decrease as the D.C. voltage from the Motor Control Board increases or decreases
respectively.
(S/N 4390 and UP
1000 Series)
(S/N 4390 to 14790
1200 Series)
(S/N 14791 & Above
1200 Series
See Page 9
Closing the fan switch and the normally open Conveyor switch supplies 120 VAC to
the Motor Control Board. AC volts are converted to DC volts and are supplied to the
Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control
Potentiometer (5,000 ohm 10 turn ) will change resistance at terminals P1, P2, and
P3 varying the DC voltage to the motor. The speed of the conveyor motor will
increase or decrease as the DC voltage from the board increases or decreases
respectively. As the motor turns, it drives both the reducer gearbox and the tach.
generator. The tach. generator is a DC voltage generator which supplies a voltage to
the DC motor control board and is used as a reference for maintaining a constant
conveyor speed.
NOTE The 1200 Series Ovens utilize 2 complete conveyor drive systems.
TIME TEMP
DISPLAY(S/N 4390 &
Above1000 Series) S/N
4390-147901200 Series)
(T/T Display S/N
Q14791& Above1200
Series See Page 9
The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120
VAC to the primary of the 12.6 volt Transformer. The secondary output of the
transformer, normally 13 to 14 VAC (depending on input), with a center tap, is
supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is
terminal 2. The display works on a balanced input and center tap voltage to each leg
must be 1/2 the total reading.
The speed side of the Time/Temp. Display uses a slotted.disc (cemented to tach.
coupling) to break the infra-red light beam of the optical switch (mounted on gear
motor) producing electrical pulses that are transmitted to the display. The display
converts these pulses into a read-out of minutes and seconds.
The temperature portion of the display uses a Thermistor Probe to sense oven
temperature. The thermistor outputs a resistance proportional to the oven
temperature. This resistance is then converted by the display into a temperature
reading.
NOTE The 1200 Series Ovens use a Double Pole Double Throw Switch to connect the two
Optical Encoder Assemblies to the Time/Temp. Display. By activating the switch,
either the front or rear belt speed can be shown by the Time/Temp. Display.
SEQUENCE OF OPERATIONS 1030
MODEL 1030 - 220 VAC - 50HZ - 1 PHASE
POWER SUPPLY Electrical Power to be supplied to the Oven by a three conductor service.
Black conductor is Hot
Red conductor is Neutra
Green conductor is Ground
CONTROL BOX
AUTO COOL DOWN
When the temperature in the Control Box reaches 120°F + 3°, the Cooling Fan
Thermostat will switch power to the Control Box Cooling Fan. The Thermostat will
interrupt power to the Cooling Fan when the Control Box temperature falls to 100°F +
3°.
MAIN FAN CIRCUIT Electrical power is permanently supplied to the normally open contacts of the Double
Pole Main Fan Relay, the Cooling Fan Thermostat, the normally open Main Fan
Switch, and the normally open Cool Down Thermostat (thermostat closes at 160°F
and opens at 140°F). Closing the Main Fan Switch supplies 220 VAC through a 3A
Fuse to the (normally open) Burner Switch, and to the control circuit Step Down
Transformer (the transformer steps the voltage down to 120 VAC for the control
circuit) 120 VAC is supplied to the coil of the Main Fan Relay The coil is energized,
the normally open contacts close, supplying 220 VAC through one 10A Fuse to the
Main Fan Motor. 120 VAC is also supplied to the 12.6 VAC Transformer, the
Temperature Controller and the Conveyor Switch.
TRANSFORMER (12.6
VAC)
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to
Impinger I -–1000 Series Service Manual - International 7
14 VAC) with a center tap, and supplies power to the Time/Temp Display. The
voltage from each leg of the Transformer's secondary to the center tap should be
one half of the secondary voltage
BURNER CIRCUIT Closing the normally open Burner Switch supplies 220 VAC, through the gas
pressure-proving switch, and through the Main Fan Air Pressure Switch, to the
Ignition Control. The combustion motor relay is energized, its normally open contacts
now close, supplying120 VAC to the combustion motor. The normally open
combustion air switch closes upon sensing air. After pre-purge period of between 30
and 60 seconds, the Ignition Transformer is energized and the Main Gas Valve is
energized. Ignition should now occur.
TEMPERATURE
CONTROL
Closing the Fan Switch supplies (through the Step down Transformer) 120 VAC to
the Temperature Control Board. The 2.5K ohm Temperature Potentiometer is
adjusted to desired temperature. The Thermocouple will provide varying millivolts to
the Temperature Controller. The Temperature Controller supplies 120 VAC to the
Solenoid Valve at intermittent intervals to maintain desired temperature.
CONVEYOR DRIVE
(S/N4390-Q17170)
(Conveyor Drive
Q171701 & Above See
Page 9)
Closing the fan switch and the normally open conveyor switch supplies 120 VAC to
the Motor Control Board. AC volts are converted to DC volts and are supplied to the
Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control
Potentiometer (5,000 ohm 10 turn) will change resistance at terminals P1, P2, and
P3 varying the DC voltage to the Conveyor Motor. The speed of the conveyor motor
will increase or decrease as the DC voltage from the board increases or decreases
respectively. As the motor turns, it drives both the reducer gearbox and the tach.
generator. The tach. generator is a DC voltage generator which supplies a voltage to
the DC motor control board and is used as a reference for maintaining a constant
conveyor speed.
(Time/Temp Display
Q17171 & Above See
Page 9)
The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120
VAC to the primary of the 12.6 volt Transformer. The secondary output of the
transformer, normally 13 to 14 VAC (depending on input), with a center tap, is
supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is
terminal 2. The display works on a balanced input and center tap voltage to each leg
must be 1/2 the total reading.
TIME/TEMP
DISPLAY(Q17171 &
Above See Page 9
The speed side of the Time Temp. Display uses a slotted disc (cemented to tach.
coupling) to break the infra-red light beam of the optical switch (mounted on gear
motor) producing electrical pulses that are transmitted to the display. The display
converts these pulses into a read-out of minutes and seconds.
The temperature portion of the display uses a Thermistor Probe to sense oven
temperature. The thermistor outputs a resistance proportional to the oven
temperature. This resistance is then converted by the display into a temperature
reading.
SEQUENCE OF OPERTIONS 1032
MODEL 1032 - 380Y/220 VAC - 50 HZ - 3 PHASE
POWER SUPPLY Electrical Power to be supplied to the Oven by a five conductor service
Black conductor is Hot
Red conductor is Hot
Orange conductor is Hot
White conductor is Dedicated Neutral
Green conductor is Ground
MAIN FAN CIRCUIT Electrical power is permanently supplied through 3, 50A fuses to the normally open
contacts of the Mercury Contactor. Power is also supplied through one 10A fuse to
the normally open contact of the Main Fan Relay, through a 1A Fuse to the normally
open Double Pole Main Fan Switch, and to the normally open Cool-Down
Thermostat (thermostat closes at 160°F and opens at 140°F.) Closing the Main Fan
Switch supplies 220VAC to the primary of the control circuit Step Down Transformer.
(The transformer steps the voltage down to 120 VAC for the control circuit.) 120 VAC
is supplied to the coil of the Main Fan Relay. The coil of the relay is energized, the
normally open contacts close, energizing the Main Fan Motor. Closing the Main Fan
Switch also supplies power to the 12.6 VAC Transformer, the Control Box Cooling
Impinger I -–1000 Series Service Manual - International 8
Fan, and the Heat and Conveyor Switches.
TRANSFORMER (12.6
VAC)
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to
14 VAC) with a center tap, and supplies power to the Time/Temp Display. The
voltage from each leg of the Transformer's secondary to the center tap should be
one half of the secondary voltage.
HEAT CIRCUIT Closing the Fan Switch and the normally open Heat Switch supplies 120 VAC
through the normally open Air Pressure Switch, and the normally closed Hi-Limit
Thermostat (manually re-settable, opens at 368°C) through the 3A Fuse, to the
Temperature Control Board, the coil of the Mercury Contactor, and to the Heat
Indicator Light.
TEMPERATURE
CONTROL
When the Heat Switch is closed, 120 VAC is supplied to the Temperature Control.
The Temperature Control Potentiometer (2.5K ohm) is adjusted to desired
temperature. The Thermocouple will provide varying millivolts to the Temperature
Controller. The Temperature Controller switches the L2 line of the Contactor coil at
intermittent intervals to maintain desired temperature.
CONVEYOR DRIVE
(S/N 4390 AND UP)
Closing the fan switch and the normally open conveyor switch supplies 120 VAC to
the Motor Control Board AC volts are converted to DC volts and are supplied to the
Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control
Potentiometer (5,000 ohm 10 turn ) will change resistance at terminals P1, P2, and
P3 varying the DC voltage to the Conveyor Motor. The speed of the conveyor motor
will increase or decrease as the DC voltage from the board increases or decreases
respectively. As the motor turns, it drives both the reducer gear box and the tach.
generator. The tach. generator is a DC voltage generator which supplies a voltage to
the DC motor control board and is used as a reference for maintaining a constant
conveyor speed.
TIME TEMP DISPLAY The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120
VAC to the primary of the12.6 volt Transformer. The secondary output of the
transformer, normally 13 to 14 VAC (depending on input), with a center tap, is
supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is
terminal 2.The display works on a balanced input and center tap voltage to each leg
must be 1/2 the total reading.
The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach.
coupling) to break the infra-red light beam of the optical switch (mounted on gear
motor) producing electrical pulses that are transmitted to the display. The display
converts these pulses into a read-out of minutes and seconds.
The temperature portion of the display uses a Thermistor Probe to sense oven
temperature. The thermistor outputs a resistance proportional to the oven
temperature. This resistance is then converted by the display into a temperature
reading.
SEQUENCE OF OPERATIONS / 1033, 1034, 1046, 1047
MODEL 1033 / 220 VAC - 50HZ / NATURAL GAS
MODEL 1034 / 220 VAC - 50HZ / L.P. GAS
MODEL 1046 / 240 VAC - 50HZ / NATURAL GAS
MODEL 1047 / 240 VAC - 50HZ / L.P. GAS
POWER SUPPLY Electrical Power to be supplies to the oven by a three-conductor service.
Brown conductor is Hot
Blue conductor is Neutral
Green conductor is Ground
CONTROL BOX AUTO
COOL DOWN
When the temperature in the Control Box reaches 120°F± 3°, the Cooling Fan
Thermostat will switch power to the Control Box Cooling Fan. The Thermostat will
interrupt power to the Cooling Fan when the Control Box temperature falls to
100°F±3°.
MAIN FAN CIRCUIT Electrical power is permanently supplied to the normally open contacts of the oven
fan motor relay, the Cooling Fan Thermostat, and the normally open Oven Fan
Switch. Closing the oven fan switch supplies 220 VAC, through a 3 AMP Fuse, to the
primary of the Power Transformer (the transformer steps the voltage down to 120
VAC for the control circuit). 120 VAC is supplied to the Cooling Fan, the normally
open Conveyor Switch, the Electronic Temperature Control, and to the coil of the
Impinger I -–1000 Series Service Manual - International 9
oven start and cool down relay. Its normally open contacts close, supplying 220 VAC
to the Burner Switch and enabling the 20-minute Time Delay module. The 20-minute
Time Delay module supplies 120 VAC to the oven fan motor relay, these normally
open contacts now close, supplying 220 VAC to the Oven Fan Motor.
TRANSFORMER(12.6V
AC)
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to 14
VAC) with a center tap, and supplies power to the Time/Temp Display. The voltage
from each leg of the Transformer's secondary to the center tap should be one half of
the secondary voltage.
BURNER CIRCUIT Closing the normally open burner switch supplies 220 VAC through the oven air
pressure switch, the gas inlet pressure switch, the normally closed high limit
thermostat (opens at 368°C) to the ignition control. The combustion motor is now
energized. The normally open burner blower air pressure switch closes upon sensing
air pressure. After a pre-purge period of 30-60 seconds, the main gas valve and the
spark generator are energized. Ignition should now occur. After proving the pilot
flame, and a 30 second delay, the gas control relay and the burner indicator lamp are
energized.
TEMPERATURE
CONTROL
Closing the Fan Switch supplies (through the Step Down Transformer) 120 VAC to
the Temperature Control Board. The Temperature Potentiometer is adjusted to
desired temperature. The Thermocouple will provide varying millivolts to the
Temperature Controller. The Temperature Controller supplies 120 VAC to the
Solenoid Valve at intermittent intervals to maintain desired temperature. (An
electronic flame monitor proves main flame operation in the 1033-1034 models)
CONVEYOR DRIVE Closing the Oven Fan Switch supplies 120 VAC, through the Power Transformer, to
the normally open Conveyor Switch. Closing the Conveyor Switch supplies 120 VAC,
through a 3 AMP Fuse, to the primary of the Conveyor Control Transformer. The
secondary of this Transformer supplies 10 VAC and 29 VAC to the Conveyor Control.
The conveyor control supplies voltage pulses to the Conveyor Control. The Conveyor
Control Potentiometer varies the frequency of these pulses. The motor speed will
increase or decrease, as the frequency of the pulses increase or decrease
respectively.
TIME TEMP DISPLAY Closing the Oven Fan Switch supplies 120 VAC, through the Power Transformer, to
the primary of the Time/Temp. Transformer. The secondary output of the
Transformers, 12.5 to 15 VAC with a center tap, is supplies to terminals 1, 2, and of
the Time/Temp. Display. The display works on a balanced input, and the center tap
voltage to each leg must be 1/2 the total reading.The speed side of the Time/Temp.
Display is supplied, by the Conveyor Control, with the frequency of the pulses to the
Conveyor Motor. This frequency is converted by the Time/Temp. Display into a read
out of minutes and seconds. NOTE: The Conveyor Control uses a sensor and
magnet, mounted on the Conveyor Motor that senses when the motor is not turning. If
the motor is not turning, the Time/Temp Display will show --:-- in the window. The
temperature portion of the display uses a Thermistor Probe to sense oven
temperature. The Thermistor outputs a resistance proportional to oven temperature.
This resistance is then converted by the Display into a temperature reading.
OR:
The temperature portion of the display uses a "J" type thermocouple to measure oven
temperature. The thermocouple generates D.C. millivolts proportional to oven
temperature. This millivolt reading is then converted by the display into a temperature
reading.
Impinger I -–1000 Series Service Manual - International 10
SEQUENCE OF OPERATIONS 1042 / 1043 / 1242 / 1243
MODEL 1042 - 240V - 50HZ - NATURAL GAS
MODEL 1043 - 240V - 50HZ - L.P. GAS
MODEL 1242 - 240V - 50HZ - NATURAL GAS/DUAL BELT
MODEL 1243 - 240V - 50HZ - L.P.GAS/DUAL BELT
POWER SUPPLY Electrical Power to be supplied to the Oven by a three conductor service.
Black conductor is Hot
Red conductor is Neutral
Green conductor is Ground
CONTROL BOX AUTO
COOL DOWN
When the temperature in the Control Box reaches 120°F + 3°, the Cooling Fan
Thermostat will switch power to the Control Box Cooling Fan. The Thermostat will
interrupt power to the Cooling Fan when the Control Box temperature falls to 100°F +
3°.
MAIN FAN CIRCUIT Electrical power is permanently supplied to the normally open contacts of the Double
Pole Main Fan Relay, the Cooling Fan Thermostat, the normally open Double Pole
Main Fan Switch, and the normally open Cool Down Thermostat (thermostat closes
at 160°F and opens at 140°F). Closing the Main Fan Switch supplies 240 VAC
through a 3A Fuse to the primary of the control circuit Step Down Transformer. The
Transformer steps the voltage down to 120 VAC for the control circuit. 120 VAC is
supplied to the coil of the Double Pole Main Fan Relay. The coil of the relay is
energized. The normally open contacts now close, energizing the Main Fan Motor
through one 10A Fuse. Closing the Fan Switch also supplies power to the Cooling
Fan, the 12.6 VAC Transformer the Burner and Conveyor Switches.
TRANSFORMER (12.6
VAC)
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to
14 VAC) with a center tap, and supplies power to the Time/Temp Display. The
voltage from each leg of the Transformer's secondary to the center tap should be
one half of the secondary voltage.
BURNER CIRCUIT Closing the Fan Switch and the normally open Burner Switch supplies 120 VAC
through the Air Pressure Switch, to the Temperature Control Board, the normally
open contacts of the Burner Motor Relay (Burner Motor Relay discontinued after S/N
14791) and the primary of the 24 VAC Transformer. The transformer's secondary
supplies 24 VAC to the burner motor relay coil (the normally open contacts close
within 30 seconds), and the normally open Centrifugal Switch. When the relay
contacts close, the Burner Blower Motor is energized. As this motor reaches approx.
1,600 R.P.M its internal centrifugal switch closes, supplying 24 VAC to the Gas
Control Valve. When the Gas Control Valve is supplied with 24 VAC, the pilot valve
is energized, and the igniter circuit is energized. Ignition should now occur. After pilot
flame is proven, the Main Gas Valve is energized. The Burner Indicator Light is also
energized.
TEMPERATURE
CONTROL
CONVEYOR DRIVE
(S/N Q14790 & Below,
1200 series
S/N Q14973 & Below,
1000 series)
(S/N Q14791 & Above,
1200 series
S/N Q14974 & Above,
1000 series refer to
Pg. 9)
Closing the Fan Switch and Burner Switch supplies 120 VAC to the Temperature
Control Board. The 1K or 1000 ohm Temperature Potentiometer is adjusted to
desired temperature. The Thermocouple will provide varying millivolts to the
Temperature Controller. The Temperature Controller supplies 120 VAC to the
Solenoid Valve at intermittent intervals to maintain desired temperature.
Closing the fan switch and the normally open conveyor switch supplies 120 VAC to
the Motor Control Board. AC volts are converted to DC volts and are supplied to the
Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control
Potentiometer (5,000 ohm 10 turn ) will change resistance at terminals P1, P2, and
P3 varying the DC voltage to the motor. The speed of the conveyor motor will
increase or decrease as the DC voltage from the board increases or decreases
respectively. As the motor turns, it drives both the reducer gearbox and the tach.
generator. The tach. generator is a DC voltage generator which supplies a voltage to
the DC motor control board and is used as a reference for maintaining a constant
conveyor speed.
Impinger I -–1000 Series Service Manual - International 11
TIME/TEMP
DISPLAY(S/N Q14790 &
Below, 1200 series S/N
Q14973 & Below, 1000
series)
(S/N Q14791 & Above,
1200 series S/N Q14974
& Above,
1000 series refer to Pg.
9)
The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120
VAC to the primary of the12.6 volt Transformer. The secondary output of the
transformer, normally 13 to 14 VAC (depending on input), with a center tap, is
supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is
terminal 2. The display works on a balanced input and center tap voltage to each leg
must be 1/2 the total reading.
The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach.
coupling) to break the infra-red light beam of the optical switch (mounted on gear
motor) producing electrical pulses that are transmitted to the display. The display
converts these pulses into a read-out of minutes and seconds. The temperature
portion of the display uses a Thermistor Probe to sense oven temperature. The
thermistor outputs a resistance proportional to the oven temperature. This resistance
is then converted by the display into a temperature reading.
Impinger I -–1000 Series Service Manual - International 12
SCHEMATIC / 1002, 1003
Impinger I -–1000 Series Service Manual - International 13
SCHEMATIC / 1006 TO SERIAL NUMBERS Q14279
Impinger I -–1000 Series Service Manual - International 14
SCHEMATIC / 1028, 1029, S/N Q19071 & BELOW
Impinger I -–1000 Series Service Manual - International 15
SCHEMATIC / 1028, 1029, S/N Q19078 & ABOVE
Impinger I -–1000 Series Service Manual - International 16
SCHEMATIC / 1030, TO S/N Q17170
Impinger I -–1000 Series Service Manual - International 17
SCHEMATIC / 1030, S/N Q17171 & ABOVE
Impinger I -–1000 Series Service Manual - International 18
SCHEMATIC / 1032. S/N Q19077 & BELOW
Impinger I -–1000 Series Service Manual - International 19
SCHEMATIC / 1032, S/N Q19078 & ABOVE
Impinger I -–1000 Series Service Manual - International 20
SCHEMATIC / 1033, 1034, 1046, 1047
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112

Lincoln Manufacturing Series 1000 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI