CERBERUS PYROTRONICS Conventional Fire Alarm Systems Owner's manual

Category
Fire protection
Type
Owner's manual

CERBERUS PYROTRONICS Conventional Fire Alarm Systems are user-friendly and packed with features to protect your property. It offers easy operation with an ATM-style display for programming and operating fire alarm control panels. The system includes a range of notification appliances, detectors, and communication devices to suit various needs. It ensures reliable monitoring, alarm activation, and notification during fire emergencies.

CERBERUS PYROTRONICS Conventional Fire Alarm Systems are user-friendly and packed with features to protect your property. It offers easy operation with an ATM-style display for programming and operating fire alarm control panels. The system includes a range of notification appliances, detectors, and communication devices to suit various needs. It ensures reliable monitoring, alarm activation, and notification during fire emergencies.

Conventional Fire Alarm
Systems & Accessories
6200
CATALOG NUMBER
l12 Zones Expandable to 32
l10 Amp Power Supply
Expandable to 20
l4 Notification Appliance
Circuits Expandable to 16
l2 Amps per Notification
Appliance Circuit
PXL Fire Alarm Control
lFeatures Easy to Use, ATM-Style
Display for Operating & Programming
l4 Zones Expandable to 8
l3 Amp Power Supply
l2 Notification Appliances Circuits
lField Programmable Software Features
for Every Application
SXL Fire Alarm Control
Fire Alarm Control Panels
All of Cerberus Pyrotronics conventional Fire Alarm Controls
are listed/approved by UL, ULC, CSFM & NYMEA. These
microprocessor based panels are listed as compatible with
all of the accessories included here. They also include
software based features to meet any need including
supervisory monitoring, waterflow alarms, event history logs
and zone bypass. They provide a complete system solution
for any zoned building.
Order Model PXL, Part No. 599-694189
Order Model SXL, Part No. 599-692530
firealarmresources.com
lAdvanced Field Cleanable Chamber Design
lUL Listed Self Test Feature
lMulti-Color LED for Normal, Trouble or
Alarm Indication
lLow-Profile Design
lEasy Twist-In Base Design
lMade in USA at ISO 9001 Facility
lListed, ULC Listed, FM, CSFM,
NYMEA Approved
PE-11 Self Diagnostic Detector
Smoke Detectors
Cerberus Pyrotronics smoke detectors have been devel-
oped using an extensive history of fire test data. This
experience is designed into new technology products
which provide high reliability while reducing installation
cost and test time.
DI-3 Ionization Smoke Detector
lTransmitter and Receiver Installed in the
Same Housing
lEasy Alignment and Installation
lTwo-Wire Installation
lSuitable for Ranges from 17 Feet to 280 Feet
lResponse Behavior Selectable in Three
Sensitivity Settings
lHigh Immunity to Extraneous Light
lAutomatic and Comprehensive Self-Test
lOperates According to the Principle of Light-
Attenuation by Smoke
Linear Beam Smoke Detector
lAdjustable Sensitivity
lDual Chamber
lSensitivity Test Points
lSimple Twist/Lock Assembly
lOptional Auxiliary Relay
lScrew-Clamp Terminals
lAlarm LED
lListed, ULC Listed, FM, CSFM,
NYMEA Approved
Order Detector Model PBA-1191, Part No. 500-095076
Order Base Model PBB-1191, Part No. 500-095077
Order Reflector Model PBR-1191, Part No. 500-095078
Order Detector Model DI-3, Part No. 500-081806
Order Base Model DB-3S, Part No. 595-381804
The DI-3 has standardized the ionization detection principle
for over 15 years. PE-11 uses a self-test feature to eliminate
the need for special sensitivity meters. The PBA-1191
contains both transmitter and receiver in one housing to
reduce installed wiring costs. These devices satisfy any
smoke detection problem.
Order Detector Model PE-11, Part No. 500-094150
Order Base Model DB-11, Part No. 500-094151
firealarmresources.com
l25 or 70.7 VRMS Audio (Field Selected)
lTrue 100 Watts RMS Output Capacity
lUp to 11 Optional Speaker and Strobe
Circuit Modules in One Cabinet
lAll Outputs are Power Limited & Supervised
lStyle Y (Class B) and Style Z (Class A)
Speaker and Strobe Circuits
lDry Contact or polarity reversal Activation
lActivation Inputs are Fully Supervised
lOptional Digital MessageMaker is Field
Programmable
lCoded Tone Option
lBackup Evacuation Tone Option
lStand Alone or for Use with any Fire Alarm/
Suppression Control Panel
lListed, ULC Listed, CSFM, NYMEA
Approved
VoiceCom Voice/Alarm Communication System
PAD-2 Auxiliary Power Supply / NAC Extender
l6 Amps of Notification Appliance Power
lAdvanced Microprocessor Control
l24 VDC Regulated Output Voltage
lFour Power-Limited Notification Outputs
lSynchronized ANSI Temporal Pattern
lClass ‘A’ Selectable
lGround Fault Detection
lBattery Supervision
l3 Amp Auxiliary Power Output
lTrouble Contact for Monitoring
lListed
Order Model VoiceCom, Part No. 500-693713 (50 Watts)
Order Model VoiceCom-MM, Part No. 500-693714
(50 Watts with MessageMaker)
Order Model VoiceCom-L, Part No. 500-694227 (100 Watts)
Order Model PAD-2, Part No. 500-694275
Building Evacuation
The Americans with Disabilities Act has driven the need for
notification capacity in all buildings. VoiceCom Emergency
Voice/Alarm Evacuation System and the PAD-2 NAC
Extender provide for the control of notification appliances
throughout any structure. Both products can be configured
in multiple ways to meet local codes for installation as well
as for safe building evacuation.
firealarmresources.com
lS-Strobes 15, 15/75, 75 & 110
Candela Models
lSS-Strobes-Synchronized
lMTL - 8 Tone Electronic Horns
lMTLS - 8 Tone Horn Strobes
lE - Single Tone Horns
lES - Single Tone Horn Strobes
lHN - Electro-Mechanical Horn
lHNS - Electro-Mechanical Horn-
Strobes
lSM - Speakers ¼ to 2 Watt and
Speaker Strobes
lSH - High Output Speakers 1/3 to 2½
Watts and Speaker Strobes
lMeet the Americans with Disabilities
Act
lMeet UL 1971
F-Series Notification Appliances
Notification Appliances
Cerberus Pyrotronics F-Series Notification Appliances will satisfy the requirements of ADA and UL 1971 and are UL, ULC
Listed compatible with our systems. Additionally, they provide for a range of tones, audibility levels, strobe power and
synchronization of strobes to meet the needs of all types of building occupancy. F-Series devices also feature low power
consumption to minimize system demand and low in-rush duration to improve system reliability.
How to Read F-Series Signal Model Numbers
Most F-Series products follow a simple pattern as follows: the first series of letters/numbers describe the base signal class,
the second set describe the strobe if applicable, the third set describes the mounting configuration. Please refer to the
specific catalog sheet for each base signal class.
Example: MTL - S17S - FW
MTL= 8-tone multi-tone horn
MC= 3-tone horn
EC= Electronic chime
EH= Electronic horn
EW= Electronic slow-whoop
HN= Electron-mechanical horn
HNH= Electron-mechanical, high dB
MH= Mini-horn
MMT= 8-tone in mini-horn plastic
TTH= Tri-tone horn
SM25= Lo-profile 25 volt speaker
SM70= Lo-profile 70 volt speaker
SH25= High output 25 volt speaker
SH70= hHgh output 70 volt speaker
BF= Bell 4 inch
BS= Bell 6 inch
BE= Bell 8 inch
BT= Bell 10 inch
CH= Mechanical chime
S15= 15 cd strobe
S17= 15/75 cd strobe
S75= 75 cd strobe
S110= 110 cd strobe
S15S= 15 cd strobe, synchronous
S17S= 15/75 cd strobe, synchronous
S75S= 75 cd strobe, synchronous
-EP= Explosion proof
-LC= Low current draw
-SS= Single stroke
-AC= 120 VAC
-6060H= 6” x 6” horizontal
-6090V= 6” x 9” vertical
-S= Surface mount
-SW= Surface, white
-F= Flush mount
-FW= Flush, white
-C= Ceiling mount
firealarmresources.com
l8 or 16-Zone LED Display
lAnnunciates Zone Alarms, Supervisory and
Trouble Conditions
lSurface or Semi-Flush Installation
l4-Wire Connection to SXL or PXL
(Supervised)
l2 Remote Annunciators per SXL or PXL
lListed, ULC Listed, FM, CSFM,
NYMEA Approved
LED Series Remote Annunciators
5128 & 5129 Digital Alarm Communicators
l864 Listed. Meets NFPA 72 Chapter 4, for
Central Station/Remote Station Monitoring
lListed as a Slave Communicator for
Connection to System 3TM, SXL, IXL, and
MXL Fire Alarm Control Panels
lFour Fully Supervised Input Channels
lDual Phone Line Interface and Line Fault
Monitoring
lAutomatic 24 Hour Test
lReports in Eight (8) Standard Communication
Formats
lLocal Keypad Programmer/Annunciator (5230)
lRemote Programming (Up/Down Loading)
Fire System Communicators
Communication of alarm and trouble information in and out
of the protected building is critical to proper fire protection.
The LED Series annunciators provide annunciation through-
out the building in many formats to suit the building and the
fire alarm control. The 5128 and 5129 communicators
reliably carry system conditions to a central station.
Ordering Information
Model Part Number Description
LED-3 500-693062 8 Zone Serial Annunciator -
Black, SXL & PXL
LED-4 500-693317 8 Zone Serial Annunciator -
White, SXL & PXL
LED-8R 500-395661 8 Zone Annuniator - Red
LED-8B 500-395662 8 Zone Annuniator - Black
LED-8RTL 500-395663 8 Zone Annunciator - with
Lamp Test & Trouble - Red
LED-8BTL 500-395664 8 Zone Annunciator - with
Lamp Test & Trouble - Black
LED-16R 500-395665 16 Zone Annunciator - Red
LED-16B 500-395666 16 Zone Annunciator - Black
LED-16RTL 500-395663 16 Zone Annunciator - with
Lamp Test & Trouble - Red
LED-16BTL 500-395664 16 Zone Annunciator - with
Lamp Test & Trouble - Black
5128 500-693213 4 Channel Communicator -
Mounts inside FACP
5129 500-693214 4 Channel Communicator with
Enclosure
5230 500-693215 Programmer/Annunciator for
5128 & 5129
firealarmresources.com
MS Series Manual Fire Alarm Boxes
lDurable Plastic Design
lShock and Vibration Resistant
lActivation Visibly Noticeable
lOptional Contact Arrangements
lOptions Include Keyswitch or Alarm
Lamp
lNo Break Rods Necessary
lSurface or Semi-Flush Installation
lMetal Versions Available
lListed, FM and CSFM Approved
DT Series Thermal Fire Detectors
lFixed Temperatures 135°F and
200°F
lRate of Rise
lRate Compensation / Fixed
Temperature
lExplosion Proof Models Available
lWeatherproof Models Available
lListed, ULC Listed, CSFM,
NYMEA and FM Approved
Initiating Devices
Cerberus Pyrotronics supplies a wide range of manual
stations and thermal detectors to round out any installation.
Outdoor use, explosion proof environments and other
special applications can be satisfied with MS and DT series
devices
April 1997
New Issue
4/97
10M
CPY-IG
Printed in U.S.A.
Cerberus Pyrotronics
8 Ridgedale Avenue
Cedar Knolls, NJ 07927
Tel: (201) 267-1300
FAX: (201) 397-7008
Website: www.cerbpyro.com
Cerberus Pyrotronics
50 East Pearce Street
Richmond Hill, Ontario
L4B, 1B7 CN
Tel: (905) 764-8384
FAX: (905) 731-9182
firealarmresources.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

CERBERUS PYROTRONICS Conventional Fire Alarm Systems Owner's manual

Category
Fire protection
Type
Owner's manual

CERBERUS PYROTRONICS Conventional Fire Alarm Systems are user-friendly and packed with features to protect your property. It offers easy operation with an ATM-style display for programming and operating fire alarm control panels. The system includes a range of notification appliances, detectors, and communication devices to suit various needs. It ensures reliable monitoring, alarm activation, and notification during fire emergencies.

Ask a question and I''ll find the answer in the document