Skanti VHF 9110 is a highly capable and versatile portable VHF transceiver designed to meet the stringent requirements of the Global Maritime Distress and Safety System (GMDSS). Some of the key capabilities and possible use cases of the Skanti VHF 9110 include:

  • Emergency Communication: The Skanti VHF 9110 is equipped with a dedicated emergency battery that provides at least 8 hours of operation, even in extreme cold (-20°C). This ensures that you have a reliable means of communication in the event of an emergency at sea.

  • Simplex and Distress Channel Operation: The Skanti VHF 9110 provides quick and easy access to all international simplex channels, as well as distress channel 16. This allows you to communicate with other vessels in your vicinity or to issue distress calls in the event of an emergency.

Skanti VHF 9110

Skanti VHF 9110 is a highly capable and versatile portable VHF transceiver designed to meet the stringent requirements of the Global Maritime Distress and Safety System (GMDSS). Some of the key capabilities and possible use cases of the Skanti VHF 9110 include:

  • Emergency Communication: The Skanti VHF 9110 is equipped with a dedicated emergency battery that provides at least 8 hours of operation, even in extreme cold (-20°C). This ensures that you have a reliable means of communication in the event of an emergency at sea.

  • Simplex and Distress Channel Operation: The Skanti VHF 9110 provides quick and easy access to all international simplex channels, as well as distress channel 16. This allows you to communicate with other vessels in your vicinity or to issue distress calls in the event of an emergency.

SKANTI provides the total
GMDSS communication
package consisting of:
- HF SSB radiotelephones with
200/250/400/750W output
power
- Digital Selective Calling
(DSC) for MF/HF/VHF
- Radiotelex
- VHF/Hand-held VHF
- IBM-compatibel PC and printer
- 2182 kHz watch receiver
- Cospas-Sarsat EPIRB
- Inmarsat terminals
- Wide range of accessories
for system installation
VHF 9110
VHF 9110
28442A
MONITOR
LAMP
PTT
CALL
Monitor switch for listening-in on a
channel, irrespective of the
squelch level setting.
Backlight switch, used to turn-on
the illumination of the display and/
or the keyboard, depending on
programming.
PTT switch.
(Call switch, for selective calling.)
Microphone.
VHF 9110
Display read-out
SQ
HI VOL
DUP
TX
LO
1 2 3 4 5
101112 9 7 6
28443
8
1. HIgh - LOw, TX power level indicators.
2. TX on indicator, (carrier is transmitted).
3. DUPlex channel indicator.
4. Volume indicator, on in high level AF
power mode.
5. VOLume sign, the two digits below indicate
the actual volume setting.
6. 8 alpha-numeric digits, used for channel
number indication etc.
7. Squelch sign, the two digits above indicate the
actual squelch setting.
8. Battery low indicator.
9. Keyboard lock indicator.
10.Individual call alarm indicator.*
11. AF-mute indicator.*
12. Tone system ON indicator.*
* Functional only in conjunction with
optional tone module for selective calling.
VHF 9110
Contents
Page
Introduction 1
Emergency 3
Batteries 4
Operator's guide 5
Quick channel programming 7
Additional features 8
Installation 10
Rechargeable batteries 11
Mounting of clip 13
Removing clip 14
1 VHF 9110
Introduction
SKANTI VHF 9110, your new VHF-transceiver,
is approved to fulfil the GMDSS-requirements to
portable VHF-transceivers, and so it is a part of
the required safety equipment to be used in an
emergency situation.
However, the best way to guarantee func-
tionality in an emergency, is to use the e-
quipment in the daily work on-board, as a useful
communication media.
This is possible, due to a unique concept, with
the PRIMARY EMERGENCY BATTERY, stored
for the emergency, and a SECONDARY RE-
CHARGEABLE BATTERY for daily use of your
new portable VHF-transceiver.
This concept secures at least 8 hours operation
time, even at minus 20 C° at sea.
EuroCom Industries has developed the first
portable VHF-transceiver to be used as you
normally use a telephone.
This feature gives you a much better com-
munication quality in noisy surroundings.
VHF 9110 2
Furthermore, you have all the international
simplex channels, quick selection of distress ch.
16 and two additional user programmable
channels, and a lot of other useful features.
3 VHF 9110
Emergency
Procedure for SKANTI VHF 9110
If an emergency situation forces you to leave the
ship, do as follows:
1. Remove the top-seal of the orange emer-
gency battery package.
2. Insert the battery package into the handheld
transceiver unit.
3. Push the - button,
until the radio turns on, indicated by channel
read-out in the display.
4. Push the
16
- button to ensure that the
channel for distress traffic is active.
NOTE !
Due to battery storage effects, the turn-on time
may be extended compared to normal condi-
tions. If Battery seal is broken for test, fill in label
on battery.
VHF 9110 4
Batteries
This unit has been delivered with two types of
battery packages :
* An orange PRIMARY EMERGENCY
BATTERY package, to be used in an
emergency, as indicated by its colour.
* A black SECONDARY RE-CHARGEABLE
BATTERY for daily use of the equipment.
Replacement of battery package :
Press the two stainless steel locks on each
side of the battery package with your thumb
and indexfinger and pull out the battery.
28468
* Insert the new battery package into the
bottom of the transceiver and press it
upwards until it snaps in with a click.
5 VHF 9110
Operator's guide
Press.....
Until unit turns ON/OFF, indicated by the
display readout.
To lock keyboard, indicated by
To unlock keyboard, disappears.
To select loudspeaker operation, .
To select telephone-mode operation.
To turn on keyboard beep-function.
To turn off keyboard beep-function.
To change setting of a selected function,
Default: Volume level function.
PWR
To select Tx power level function.
CH
To select Channel selection function.
SQ
To select Squelch level function.
VOL
To select Volume level function.
VHF 9110 6
A
To select quick channel A.
B
To select quick channel B.
16
To select distress channel 16.
7 VHF 9110
Quick channel programming
The two quick channel keys
A
and
B
can
easily be programmed for single touch selection
of any of the channels contained in the equip-
ment.
These keys may be programmed as follows:
Press
CH
, use the key to select the
wanted channel number, which must be shown
in the display.
then
Press the key (less than 1 sec.) followed by
the key you want to programme,
A
or
B
, for
more than 1 sec.
VHF 9110 8
Additional features
Your SKANTI VHF 9110 has some other
features which may show up to be useful in daily
use.
On the side of the transceiver you will find the
following switches (look inside the cover of this
folder):
Backlight switch for turning on/off the key-
board and display illumination (if you forget to
turn off the illumination, it will be done automati-
cally after approx. 30 seconds to increase
battery life time). The backlight function may be
programmed to operate in other ways, please
contact your SKANTI distributor.
Monitor switch for easy listening-in on the
selected channel, irrespective of the squelch
setting.
Keyboard operated facilities:
Auto squelch setting. Press
SQ
for more
than one second, the transceiver will automati-
cally find an appropriate level to mute the
receiver.
9 VHF 9110
Programmable functions:
Tx power level preset value. Select the
wanted power level and press “PWR” for more
than 1 second.
Volume level preset value. Select the wanted
level and press “VOL” for more than 1 second.
Alarm functions:
Battery warning facility. When the battery
capacity has decreaced to a few percent of full
load, an audible alarm is heard in the loud-
speaker and a battery sign will be shown in the
display. At the same time the transmitter power
level will automatically be set to LOw level, to
extend the remaining operation time of the
battery.
An audible alarm is heard each 10 seconds until
the display readout shows charGe, and the set
is switched off automatically.
VHF 9110 10
Installation
With your SKANTI VHF 9110 you have got a
combined holder/charger. If the transceiver NOT
is used in the daily work, the primary emergency
battery may be stored in the holder. If however
the charger is used frequently, the emergency
battery must be stored in another place, due to
charger heating.
The charger may be connected to 110/230 VAC,
OR a DC source 10.8 -> 31.8 VDC.
+
-
10,8 - 32V DC
AC
OR
28469
BATTERY CHARGER SP3911
ON / OFF CHAR
The charger will automatically detect the type of
battery in the transceiver, the charging process
will start when you press the Char-button and
the red charging indicator turns on. A complete
charge cycle is finished after 13 1/2 hour,
indicated by a green coloured charge indicator.
Please refer to part Rechargeable batteries for
proper use of secondary batteries.
11 VHF 9110
Rechargeable batteries
Before taken into operation, the NiCd battery
included, must be fully charged.
The battery can be stored at room temperature
in any charge condition, without any risk of
damage to the battery. However, if the battery
has been stored for an unknown period of time,
it must be fully charged before used.
The only maintenance needed for your NiCd
battery is to keep it charged and with clean
terminals. The battery must be at normal room
temperature when it is charged, and the trans-
ceiver must be switched off.
WARNING
The battery may explode if it is exposed to open
fire.
VHF 9110 12
MEMORY EFFECT. Your NiCd battery may
show a memory effect, indicated by a reduced
charging capability.
This effect will typically arise if your battery is
repeatedly charged after a partly discharge.
A battery with memory effect is not in optimum
working condition.
How to avoid memory effect:
Use your transceiver until the battery is fully
discharged, indicated by the equipment. Then
fully recharge the battery once a week.
How to brake down a memory effect:
Use your transceiver until the battery is fully
discharged then complete a charge cycle.
Repeat this procedure at least three times.
NOTE!
As an option, SKANTI can offer a special
charger, which includes a quick-charger and a
special recycle feature with measurement and
readout of actual battery capacity.
Contact your SKANTI distributor for further
information
13 VHF 9110
28457A
Mounting of clip
VHF 9110 14
Removing clip
Please note
Any responsibility or liability for loss or damage in connection
with the use of this product and the accompanying documen-
tation is disclaimed. The information in this manual is
furnished for informational use only, is subject to change
without notice, may contain errors or inaccuracies, and
represents no commitment whatsoever. This agreement is
governed by the laws of Denmark.
Doc. No.: B3110GB9 Issue: F/9939
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Skanti VHF 9110 User manual

Category
Security device components
Type
User manual

Skanti VHF 9110

Skanti VHF 9110 is a highly capable and versatile portable VHF transceiver designed to meet the stringent requirements of the Global Maritime Distress and Safety System (GMDSS). Some of the key capabilities and possible use cases of the Skanti VHF 9110 include:

  • Emergency Communication: The Skanti VHF 9110 is equipped with a dedicated emergency battery that provides at least 8 hours of operation, even in extreme cold (-20°C). This ensures that you have a reliable means of communication in the event of an emergency at sea.

  • Simplex and Distress Channel Operation: The Skanti VHF 9110 provides quick and easy access to all international simplex channels, as well as distress channel 16. This allows you to communicate with other vessels in your vicinity or to issue distress calls in the event of an emergency.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI