GHOST CONTROLS Standard Photo Eyes offer reliable protection for your automatic gate opener system. These non-monitored photo eyes feature a range of up to 50 feet and a 20-degree beam alignment range, ensuring effective coverage. With adjustable response time and simple wiring, installation is a breeze. The photo eyes can be mounted on poles or walls, providing versatility for various applications.

GHOST CONTROLS Standard Photo Eyes offer reliable protection for your automatic gate opener system. These non-monitored photo eyes feature a range of up to 50 feet and a 20-degree beam alignment range, ensuring effective coverage. With adjustable response time and simple wiring, installation is a breeze. The photo eyes can be mounted on poles or walls, providing versatility for various applications.

STANDARD PHOTO EYES
AXPS INSTRUCTIONS (NONMONITORED)
UNMONITORED PHOTO EYES INSTALLATION OVERVIEW FOR SINGLE AND DUAL GATES
SINGLE GATE DIAGRAM 1
DUAL GATE DIAGRAM 2
xx
88
LENS
TRANSMITTER
VERTICAL
FINE-TUNE
KNOB
TAMPER
SWITCH
LENS
RECEIVER
VERTICAL
FINE-TUNE
KNOB
TAMPER
SWITCH
WIRING
TERMINAL
WIRING
TERMINAL
DIP
SWITCHES
DIP
SWITCHES
WIRE HOLE WIRE HOLE
xx
88
PHOTO BEAM
PAIR 2
PHOTO BEAM
PAIR 1
PHOTO BEAM
PAIR 2
PHOTO BEAM
PAIR 3
PHOTO BEAM
PAIR 1
HOUSING
PREPARING CONTROL BOX FOR PHOTO EYE WIRING
MAKE SURE THE POWER IS TURNED OFF AND BATTERY IS DISCONNECTED TO THE CONTROL BOX BEFORE WIRING
On the bottom of the control box there is a built in knock out for wires. Drill a hole and knock it out and install a strain relief.
This is where your wires will feed up into the control box and connect to the control board.
PAIR 1 PHOTO EYE INSTALLATION AND WIRING
PAIR 1 Photo Eye RECEIVER needs to be installed on the Control Box side of the gate opener. The TRANSMITTER needs to
be installed facing and across from the RECEIVER. You will also need to dig a trench for the two (2) TRANSMITTER wires to
go across and connect the TRANSMITTER TO THE RECEIVER. The RECEIVER wires will then connect to the control box.
Use 20-22 AWG gauge stranded wire. (see CLOSING -REVERSE CONNECTION DIAGRAM next page).
CONNECTIONS FOR CLOSING-REVERSE (PAIR 1)
Transmitter Receiver Ghost Control Board
1 1 LOCK +
2 2 COM
N/A 4COM
N/A 5CLS_RVRS
(see CLOSING -REVERSE CONNECTION DIAGRAM on next page).
CLOSE-UP VIEW
KNOCK OUT
FOR STRAIN RELIEF
OF BOTTOM OF
CONTROL BOX
CLOSE-UP VIEW
STRAIN RELIEF INSTALLED
TO RUN WIRES THROUGH
STRAIN RELIEF
OF BOTTOM OF
CONTROL BOX
Trench for
power wires
Wire to CLS_RVRS on Control Board
Wire to COM on Control Board
TRANSMITTER
PHOTO BEAM
PAIR 1
Two (2) power wires feed
through trench to connect to
receiver and transmitter
RECEIVER
PHOTO BEAM
PAIR 1
Control Box
Gate swings into
property
Outside property
JUMPER WIRE between terminal 2 & 4
CLOSING -REVERSE CONNECTION DIAGRAM – PAIR 1
PAIR 2 PHOTO EYE INSTALLATION AND WIRING
PAIR 2 Photo Eye RECEIVER needs to be installed on the Control Box side of the gate opener. The TRANSMITTER needs to
be installed facing and across from the RECEIVER. You will also need to dig a trench for the two (2) TRANSMITTER wires to
go across and connect the TRANSMITTER TO THE RECEIVER. The RECEIVER wires will then connect to the control box.
Use 20-22 AWG gauge stranded wire. (see OPENING -REVERSE CONNECTION DIAGRAM next page).
CONNECTIONS FOR OPENING-REVERSE (PAIR 2)
Transmitter Receiver Ghost Control Board
1 1 LOCK +
2 2 COM
N/A 4COM
N/A 5OPN_RVRS
(see OPENING -REVERSE CONNECTION DIAGRAM on next page).
DUAL GATES: PAIR 3 PHOTO EYE INSTALLATION AND WIRING
PAIR 3 Photo Eye RECEIVER needs to be installed on the Control Box side of the gate opener. The TRANSMITTER needs to
be installed facing and across from the RECEIVER. You will also need to dig a trench for the two (2) TRANSMITTER wires to
go across and connect the TRANSMITTER TO THE RECEIVER. The RECEIVER wires will then connect to the control box.
Use 20-22 AWG gauge stranded wire. (see OPENING -REVERSE CONNECTION DIAGRAM).
DUAL ONLY: CONNECTIONS FOR OPENING-REVERSE (PAIR 3)
Transmitter Receiver Ghost Control Board
1 1 LOCK +
2 2 COM
N/A 4COM
N/A 5OPN_RVRS
(see OPENING -REVERSE CONNECTION DIAGRAM).
Control Box
Gate swings into
property
Trench for power wires
Two (2) power wires feed
through trench to connect to
receiver and transmitter
STREET VIEW
RECEIVER
PHOTO BEAM
PAIR 1
Wire to OPN_RVRS on Control Board
Wire to COM on Control Board
TRANSMITTER
PHOTO BEAM
PAIR 1
RECEIVER
PHOTO BEAM
PAIR 2
RECEIVER
PHOTO BEAM
PAIR 2
Trench for
power wires
JUMPER WIRE between terminal 2 & 4
OPENING -REVERSE CONNECTION DIAGRAM – PAIR 2
Control
Box
Gate swings
into property
Two (2) power wires feed
through trench to connect to
receiver and transmitter
Trench for power wires
STREET VIEW
RECEIVER
PHOTO BEAM
PAIR 1
TRANSMITTER
PHOTO BEAM
PAIR 1
RECEIVER
PHOTO BEAM
PAIR 2
TRANSMITTER
PHOTO BEAM
PAIR 3
Trench for
power wires
Trench for
power wires
Trench for power wires
RECEIVER
PHOTO BEAM
PAIR 3
Wire to MS-OP2 on Control Board
Wire to COM on Control Board
Wire to PWR on Control Board
Control Box
TRANSMITTER
PHOTO BEAM
PAIR 2
JUMPER WIRE between terminal 2 & 4
OPENING -REVERSE CONNECTION DIAGRAM – PAIR 3
DIP Switch
RECEIVER
DIP Switch
TRANSMITTER
PAIR 2 PHOTO EYES
PAIR 3 PHOTO EYES
DIP Switch
RECEIVER
DIP Switch
TRANSMITTER
SETTING UP THE DIP SWITCHES.
ALL UNITS COME FROM THE FACTORY PAIRED AS PAIR 1. When using more than 1 pair of photo eyes you will need to reset
switches for Pair 2 and 3 during installation with the below instructions.
PAIRING YOUR 2ND PHOTO EYES:
STEP 1: Remove + power on main control board for 2nd pair of photo eyes.
STEP 2: Place the dip switches in the positions shown in diagrams A1 and B1 above.
STEP 3: Restore + power on pair 2. Both unit’s displays will show the number 2. Leave on for 10 seconds.
STEP 4: Remove + power and reposition the dips as shown in diagrams A2 and B2.
STEP 5: Restore + power to pair 2. You are now ready to test beams to ensure proper response from the gate opener.
PAIRING YOUR 3RD PHOTO EYES:
STEP 1: Remove + power on main control board for 3rd pair of photo eyes.
STEP 2: Place the dip switches in the positions shown in diagrams C1 and D1 above.
STEP 3: Restore + power on pair 3. Both unit’s displays will show the number 2. Leave on for 10 seconds.
STEP 4: Remove + power and reposition the dips as shown in diagrams C2 and D2.
STEP 5: Restore + power to pair 3. You are now ready to test beams to ensure proper response from the gate opener.
A1
A2
B1
B2
DIP Switch
RECEIVER
DIP Switch
TRANSMITTER
PAIR 1 PHOTO EYES (FACTORY SET)
C1
C2
D1
D2
WARNING
Extreme caution must be exercised when automatic gate opener system is in operation, regardless of which safety systems are installed
and in use.
MOUNTING PRECAUTIONS
Never mount your detector where plants, direct sunlight, headlights could obstruct the beam between the transmitter and
receiver. ALSO, MAKE SURE SURFACE IS EVEN AND NOT UNSTABLE. See diagrams below
MOUNTING YOUR PHOTO EYES ON A POLE (FOLLOW DIAGRAMS BELOW)
Loosen screw on underside of Photo Eye and back out approximately 1/4 inch.
Gently lift the cover from the bottom side and angle slightly outwards (as shown).
Slide the cover upwards and then forwards to remove the cover from the housing.
USE METAL PIPE TO PREVENT MOVEMENT
MOUNTING YOUR PHOTO EYES ON A WALL (FOLLOW DIAGRAMS NEXT PAGE)
Loosen screw on underside of Photo Eye and back out approximately 1/4 inch.
Gently lift the cover from the bottom side and angle slightly outwards (as shown).
Slide the cover upwards and then forwards to remove the cover from the housing.
MOUNTING DISTANCE AND ADJUSTMENTS
The unit will turn off the display and the buzzer after 1 minute of power up. The unit is still fully functional only the
display is turned off.
ADJUSTING RESPONSE TIME ON THE RECEIVER
When set all the way clockwise means faster response time (50 msec).
When set all the way counter clockwise means slower response time (240 msec).
Factory setting response time is set approximately in the middle.
Note: for the wall-mounting method, the two rubber
knockouts will need to be removed from the housing.
Location of rubber knockouts
Hole in wall
that must be removed for
pole-mounting installation.
Beam Alignment - Housings Removed
MOUNTING
HEIGHT
SPREAD OF
BEAM AREA
RESPONSE
TIME SETTING
SENSING
AREA
RECEIVER
BEAM ALIGNMENT RANGE
UP OR DOWN 20° (± 10°)
AXPSIM | REV 0521
©2021 GHOST CONTROLS®
WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.
For more information, go to www.P65Warnings.ca.gov
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

GHOST CONTROLS Standard Photo Eyes User guide

Type
User guide

GHOST CONTROLS Standard Photo Eyes offer reliable protection for your automatic gate opener system. These non-monitored photo eyes feature a range of up to 50 feet and a 20-degree beam alignment range, ensuring effective coverage. With adjustable response time and simple wiring, installation is a breeze. The photo eyes can be mounted on poles or walls, providing versatility for various applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI