110685Rev.07/12
COMPOSITION & MATERIALS
Maycontainanyofthefollowing:
Component CAS No.
Limestone 1317-65-3
PlasterofParis 10034-76-1
Gypsum 13397-24-5
Perlite 93763-70-3
Talc 14807-96-6
Mica 12001-26-2
Clay 1302-78-9
1332-58 -7
66402-68-4
8031-18-3
Water 7732-18-5
Latex ————
VOCContent:<2g/L
ContainsNoAsbestos
INSTALLATION
RECOMMENDATIONS
InstallationofMulti-Useshould
beconsistentwithmethods
describedinthenoted
standardsandreferencesandas
indicatedbelow.
Multi-Usemayneedaslight
amountofmixingbeforeuse,
andinanycaseshouldbe
lightlymixedbeforeanywater
isadded.Mixingmaybedone
withapotato-masher-type
deviceorbyusingalow-speed
drill.Usedirectlyfromthe
containerfortreatingfasteners
andcornerbeadsorfortaping
andnishingjoints.Care
shouldbetakenwhenwater
isaddedtothintoadesired
consistency.
Applyauniformlythinlayerof
Multi-Useapproximately4”
wideoverthejointsofthe
gypsumboard.Centertape
overthejointandembedin
thecompoundtoensurea
properbond.Athincoatof
compoundshouldcoverthe
tapetominimizewrinklingor
curling.Ceilingandwallangles
aretreatedbyfoldingthetape
tottheanglesandembedding
itinthecompound.
Afterthecompoundis
thoroughlydry(approximately
24hours),coverthetapered
jointwitharstnishcoatof
Multi-Use.Spreadcompound
overthetapeabout3”toeach
sideofthetapeandfeather
outattheedge.Donotcrown
thejointwiththiscoatsince
Multi-Useislowshrinkage
andwillnotdrawbackush
tothewallboardsurface.
Afterthiscoatisthoroughly
dry,asecondnishcoatof
compoundisappliedwith
aslightuniformcrownover
thejoint.Thiscoatshould
besmooth,withtheedges
featheredout.
Allinsidecornersshouldbe
nishedwithatleastonecoat
ofMulti-Use,withtheedges
featheredout.
Allnailorscrewheaddimples
andangesofcornerbeads
shouldreceivetwocoatsof
Multi-Use.Thesecondcoat
overthebeadsshouldbe
featheredout9”onbothsides.
AlloweachapplicationofMulti-
Usetodrythoroughly,then
wetsandifnecessary.Ifdry
sandingispreferred,ventilate
usinganapprovedrespirator,
andweareyeprotection.
Incoldweather(outside
temperaturebelow50°F
[10°C]),temperatureswithin
thebuildingshouldbe
maintainedataminimum50°F
(10°C),bothdayandnight,
duringjointnishing.Adequate
ventilationshouldbeprovided
toeliminateexcessmoisture.
Wet/dampconditionsslowthe
dryingprocess;subsequently,
24hours’dryingtimebetween
coatsmaynotbesufcient.
Adequatedryingtimeis
essentialtopreventunwanted
conditionssuchascracksfrom
delayedshrinkage.
DECORATION
Beforepaint,wallcoveringor
otherdecoratingmaterials
areapplied,allareasmustbe
thoroughlydry,dustfreeand
treatedwithacoatofgood-
quality,highsolids,atlatex
primer.
Theselectionofapaintto
givethespeciedordesired
nishedcharacteristicsisthe
responsibilityofthearchitector
contractor.
GypsumAssociationGA-214,
Recommended Specication
for Levels of Gypsum Board
Finish,shouldbereferredto
inordertodeterminethelevel
ofnishingneededtoassurea
surfaceproperly
preparedtoacceptthe
desireddecoration.
TECH NICA L DATA
PACKAGING & COVERAGE
Coverageper Coverage
1,000Sq.Ft. percontainer
Package (100Sq.M)* Sq.Ft.(Sq.M)*
3.5gallon(13.2L)Carton 8-8.2Gal(32.6-33.4L) 427-438(40-41)
4.5gallon(17L)Carton 8-8.2Gal(32.6-33.4L) 550-563(51-52)
4.5gallon(17L)Pail 8-8.2Gal(32.6-33.4L) 550-563(51-52)
*Coverage varies with number of cornerbeads and trims used.
46lb.(20.9kg)Carton-AvilableWestCoastareaonly
58lb.(26.3kg)Pail-AvailableWestCoastareaonly
APPLICABLE STANDARDS AND REFERENCES
ASTMC475
ASTMC840
GypsumAssociationGA-216
GypsumAssociationGA-214
NationalGypsumCompany,Gypsum Construction Guide
ProForm
brand, Drywall Finishing Products Construction Guide
APPROXIMATE DRYING TIMES
Temperature
R.H. 32° 40° 50° 60° 70° 80° 100°
0% 38/H 28/H 19/H 13/H 9/H 6/H 3/H
20% 2/D 34/H 23/H 16/H 11/H 8/H 4/H
40% 2.5/D 44/H 29/H 20/H 14/H 10/H 5/H
50% 3/D 2/D 36/H 24/H 17/H 12/H 6/H
60% 3.5/D 2.5/D 42/H 29/H 20/H 13.5/H 8/H
70% 4.5/D 3.5/D 2.25/D 38/H 26/H 19.5/H 10/H
80% 7/D 4.5/D 3.25/D 2.25/D 38/H 27/H 14/H
90% 13/D 9/D 6/D 4.5/D 3/D 49/H 26/H
98% 53/D 37/D 26/D 18/D 12/D 9/D 5/D
Note:R.H.=RelativeHumidity D=Days(24hourperiod) H=Hours
Thechartaboveisahelpfulguideindeterminingapproximatedryingtimesforjoint
compoundsunderavarietyofhumidity/temperatureconditions.Shadedareaisbelow
theminimumapplicationtemperaturerequirementof50°andisnotrecommendedfor
theapplicationofjointcompound.