Generac 45kW RG04524JNAC User manual

  • Hello! I am an AI chatbot trained to assist you with the Generac 45kW RG04524JNAC User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
4 3 2 1
4 3 1
A
B
A
B
759 [29.9]
DOOR TYP
1171
[46.1]
OVERALL
HEIGHT
47
[1.8]
443
[17.5]
187
[7.4]
50
[2.0]
1000 [39.4]
888 [35.0]
OVERALL WIDTH
58
[2.3]
TYP
1857 [73.1] TYP
1950 [76.8]
OVERALL LENGTH
749.3 [29.5]
CENTER OF GRAVITY
(SEE NOTE 5)
SERVICE ITEM 2.4L
OIL FILL CAP EITHER SIDE
OIL DIP STICK RIGHT SIDE
OIL FILTER RIGHT SIDE
OIL DRAIN HOSE RIGHT SIDE
RADIATOR DRAIN HOSE LEFT SIDE
COOLANT RECOVERY BOTTLE LEFT SIDE
RADIATOR FILL CAP ROOF TOP
AIR CLEANER ELEMENT LEFT SIDE
SPARK PLUGS LEFT SIDE
MUFFLER SEE NOTE 11
DRIVE BELT EITHER SIDE
FAN BELT SEE NOTE 11
BATTERY LEFT SIDE
LUBE OIL MAINTAINER
SUPPLY TANK FILL CAP
ROOF TOP
WEIGHT DATA
ENGINE/KW
ENCLOSURE
MATERIAL
WEIGHT
GENSET ONLY
KG [LBS]
WEIGHT
SHIPPING SKID
KG [LBS]
SHIPPING WEIGHT
KG [LBS]
2.4L 36KW ST 569 [1255] 44 [98] 613 [1353]
2.4L 36KW AL 545 [1202] 44 [98] 590 [1300]
2.4L 45KW ST 596 [1313] 44 [98] 640 [1411]
2.4L 45KW AL 572 [1260] 44 [98] 616 [1358]
TITLE
INSTALL CPL PROT G2.4L C2
36/45KW
ISSUE DATE:
SIZE CAGE NO DWG NO
0K8636
REV
B
N/A
D
SCALE
0.050
WT-KG SEE ABOVE SHEET
1 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
SH
1/2
REV
D
WINDCHILL VERSION
D.1
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE IS 6" OFFSET OF OVERALL LENGTH
AND WIDTH OF GENERATOR. {1193.8 (47") WIDE X 2255.5 (88.8") LONG}. REFERENCE
INSTALLATION GUIDE SUPPLIED WITH THE UNIT FOR CONCRETE PAD GUIDELINES.
REFERENCE MANUFACTURER'S SPECIFICATIONS IF USING ENGINEERED, PREFABRICATED SLABS.
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.
11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE,
REMOVE FRONT PANEL TO ACCESS.
REFERENCE OWNERS MANUAL
FOR PERIODIC REPLACEMENT
PART LISTINGS.
RADIATOR/EXHAUST
DISCHARGE AIR
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
AIR INTAKE
(BOTH SIDES)
DIMENSIONS: MM [INCH]
REAR VIEW
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
CIRCUIT BREAKER
SEE NOTE 3
RIGHT SIDE VIEW
VICE ACTION LATCH,
ONE PER DOOR,
ONE LIFT OFF
DOOR PER SIDE
OF GENERATOR
LEFT SIDE VIEW
FUEL LINE CONNECTION
3/4" NPT FEMALE COUPLING
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
TOP VIEW
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
BATTERY 12V
GROUP 26
NEGATIVE GROUND
P/N: 077483
REMOVE COVER FOR
ACCESS TO LUBE OIL
MAINTAINER SUPPLY TANK
REFERENCE OWNERS MANUAL
4 3 2 1
4 3 1
A
B
A
B
1708
[67.2]
233
[9.2]
37
[1.5]
162 [6.4]
* STUB-UP
AREA
162
[6.4]
* STUB-UP
AREA
786
[30.9]
9
[.4]
51
[2.0]
50 [2.0]
TYP
1750 [68.9] TYP
MOUNTING SLOT CENTERS
1950 [76.8]
850 [33.5]
116 [4.6]
25 [1.0]
TYP
838 [33.0] TYP
MOUNTING SLOT CENTERS
888 [35.0]
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
TITLE
INSTALL CPL PROT G2.4L C2
36/45KW
ISSUE DATE:
SIZE CAGE NO DWG NO
0K8636
REV
B
N/A
D
SCALE
0.100
WT-KG SEE SHEET 1 SHEET
2 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
SH
2/2
REV
D
WINDCHILL VERSION
D.1
DIMENSIONS: MM [INCH]
* NOTE: STUB-UP AREA FOR HIGH AND LOW
VOLTAGE CONNECTIONS, CIRCUIT BREAKER,
NEUTRAL AND CUSTOMER CONNECTION OPENING.
HIGH AND LOW
VOLTAGE
STUB-UP AREA
TOP VIEW
13.5 X 29.5
MOUNTING SLOTS
4X
LEFT SIDE VIEW
REAR VIEW
REMOVABLE
STUB-UP COVER
/