Myson Unisenza User manual

Type
User manual

Myson Unisenza is an electronic thermostat designed for automatic control of heating and cooling systems. It allows you to set and maintain a comfortable temperature in your home with its precise temperature control and easy-to-use interface. With its stylish design and intuitive operation, the Myson Unisenza offers a convenient and efficient way to manage your home's climate control.

Myson Unisenza is an electronic thermostat designed for automatic control of heating and cooling systems. It allows you to set and maintain a comfortable temperature in your home with its precise temperature control and easy-to-use interface. With its stylish design and intuitive operation, the Myson Unisenza offers a convenient and efficient way to manage your home's climate control.

Installation
and user manual
Unisenza - Dial Thermostat
EN
Riscal./raffred.
Heat /Cool
Heating and
Cooling
Modalità notturna ridotta
Night set back mode
Night set
back mode
Unisenza - Dial Thermostat
Installation and user manual
EN
Index
1 SAFETY WARNING ....................................................................................................................................................................................................3
2 TECHNICAL SPECIFICATIONS ..............................................................................................................................................................................3
3 REFERENCE STANDARDS .....................................................................................................................................................................................3
4 INSTALLATION AND ELECTRICAL CONNECTION .........................................................................................................................................4
4.1 Wall fixing ..................................................................................................................................................................................................................... 4
4.2 Wiring diagram ...........................................................................................................................................................................................................4
4.2.1 Thermostat terminals description .......................................................................................................................................................................4
4.2.2 Type of wirings ............................................................................................................................................................................................................ 5
4.2.3 Connection to the Wiring Centre..........................................................................................................................................................................6
5 USER GUIDE ................................................................................................................................................................................................................6
5.1 Description ...................................................................................................................................................................................................................6
5.2 Setting the temperature setpoint ........................................................................................................................................................................7
5.3 Operating status indicator ...................................................................................................................................................................................... 7
6 WEEE DIRECTIVE APPLICATION ........................................................................................................................................................................7
1 SAFETY WARNING
During installation and operation of the device, it is neces-
sary to comply with the following instructions:
1) The device must be installed by a skilled person, in strict
compliance with the connection diagrams.
2) Do not power on or connect the device if any part of it is
damaged.
3) After installation, inaccessibility to the connection termi-
nals without appropriate tools must be granted.
4) The device must be installed and activated in compliance
with current electric systems standards.
5) Before accessing the connection terminals, verify that the
leads are not live.
2 TECHNICAL SPECIFICATIONS
Purpose of control: electronic thermostat;
Construction of control and whether the control
is electronic (see above example);
Setting range: +5/+30 °C;
Supply voltage: 230 V~ ±10 % - 50/60 Hz;
Power consumption: 3 W;
Capacity of the contacts: 2 (1) A 230 V~ (not voltage free);
Type of automatic action: 1;
Construction: Class II;
Ingress protection: IP 30;
Operating temperature: 0 °C…40 °C;
Operating humidity: 20 %...90 % rH non condensing;
Storage temperature: -20 °C…60 °C;
Shock load voltage: 2,5 KV;
Temperature for Ball Pressure Test: 90° C;
Pollution degree: 2 (normal).
3 REFERENCE STANDARDS
Conformity with EU directives:
2014/35/EU (LVD)
2014/30/EU (EMCD)
is declared with reference to the following standard:
EN 60730-2-9: Automatic electric command devices for
household and similar use.
Part 2: particular provisions for thermosensitive command
devices.
Unisenza - Dial Thermostat
Installation and user manual
EN 4 INSTALLATION AND ELECTRICAL CONNECTION
4.1 Wall fixing
LNNSB/CO SWL
LNNSB/CO SWL
CLIK
1
2
3
CLIK
4
LNNSB/CO SWL
LNNSB/CO SWL
CLIK
1
2
3
CLIK
4
LNNSB/CO SWL
LNNSB/CO SWL
CLIK
1
2
3
CLIK
4
LNNSB/CO SWL
LNNSB/CO SWL
CLIK
1
2
3
CLIK
4
4.2 Wiring diagram
4.2.1 Thermostat terminals description
P5
CO
(ON)
P5
NSB
(OFF)
LNNSB/CO SWL
LNNSB/CO SWL
Terminals 230 Vac version 24 Vac version
1. L Live input 230 Vac Live input 24 Vac
2. N Neutral input 230 Vac Neutral input 24 Vac
3. NSB
with jumper (P5) OFF
Night set back input
(Live 230 Vac input: reduced mode)
Night set back input
(Live 24 Vac input: reduced mode)
3. CO
with jumper (P5) ON
Heating and Cooling input
(Live 230 Vac input: cooling)
Heating and Cooling input
(Live 24 Vac input: cooling)
4. SWL Switch output
(Live 230 Vac during request)
Switch output
(Live 24 Vac during request)
Unisenza - Dial Thermostat
Installation and user manual
EN
4.2.2 Type of wirings
Functions Jumper Wiring diagram
Heating and cooling
function LNNSB/CO SWL
Jumper ON
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
No Live on CO/NSB terminal: Heating with
temperature setpoint setting by the knob
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
Live on CO/NSB terminal: Cooling with
temperature setpoint setting by the knob
NSB function LNNSB/CO SWL
Jumper OFF
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
No Live on CO/NSB terminal: Heating with
temperature setpoint setting by the knob
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
L
L
N
N NSB/CO SWL
Live on CO/NSB terminal: Heating with 2° C
less than the set temperature setpoint by the
knob
Unisenza - Dial Thermostat
Installation and user manual
EN
5 USER GUIDE
5.1 Description
Operating status
indicator
Setting the temperature
setpoint
4.2.3 Connection to the Wiring Centre
Dial Thermostat
Wiring Center
Zone 1 to 10
LNNSB/CO SWL
Note:
- CO connection is optional. It’s needed to use change over function. (Futher explanation in Wiring center manual).
- NSB connection is optional. It’s needed to use night setback fuction. (Further explanation in Wiring center manual).
Zone 1 to 10 (5)
or
Unisenza - Dial Thermostat
Installation and user manual
EN
6 WEEE DIRECTIVE APPLICATION - DIRECTIVE 2012/19 / EU
The crossed-out wheeled bin symbol indicates that within the European Union all electrical and electronic products at the
end of their useful life must be collected separately from other waste.
Do not dispose of this equipment in unsorted municipal waste. Assign the equipment to the appropriate collection centers
for electrical and electronic waste or return it to the retailer when purchasing a new equivalent type of equipment.
Appropriate separate collection of equipment to start the subsequent recycling, treatment and environmentally compatible
disposal helps to avoid possible negative effects on the environment and health due to the presence of hazardous sub-
stances in electrical and electronic equipment and resulting from an incorrect disposal or improper use of the same
equipment or parts thereof, the separate collection also favors the recycling of the materials of which the equipment is
composed.
The current legislation provides for sanctions in case of illegal disposal of the product.
5.2 Setting the temperature setpoint
Decrease temperature Increase temperature
5.3 Operating status indicator
Red led On - Heating Blue led On - Cooling
A PURMO GROUP BRAND
Bulevardi 46
P.O. Box 115
FI-00121 Helsinki
Finland
www.purmogroup.com
Every care has been taken in the creation of this document. No part of this document
may be reproduced without the express written consent of Purmo Group. Purmo Group
accepts no responsibility for any inaccuracies or consequences arising from the use or
misuse of the information contained herein.
23003M1810CO4EN_A - 03.2023 - AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Myson Unisenza User manual

Type
User manual

Myson Unisenza is an electronic thermostat designed for automatic control of heating and cooling systems. It allows you to set and maintain a comfortable temperature in your home with its precise temperature control and easy-to-use interface. With its stylish design and intuitive operation, the Myson Unisenza offers a convenient and efficient way to manage your home's climate control.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI