Adamson Network Distribution User manual

Type
User manual

Adamson Network Distribution is a central patch bay for signal distribution that packages multiple digital and analog signals to CS-Series loudspeakers and rack-mounted equipment. OpticalCON™ and etherCON™ connections take input from the primary and secondary LAN, combining them into a single cable for redundant networked audio to the loudspeaker system. Two analog signals can be distributed via front-panel XLRs, each split to three XLR connectors.

Adamson Network Distribution is a central patch bay for signal distribution that packages multiple digital and analog signals to CS-Series loudspeakers and rack-mounted equipment. OpticalCON™ and etherCON™ connections take input from the primary and secondary LAN, combining them into a single cable for redundant networked audio to the loudspeaker system. Two analog signals can be distributed via front-panel XLRs, each split to three XLR connectors.

Network Distribution System - User Manual
NDS
Lorem ipsum
1
NETWORK
DISTRIBUTION
SYSTEM
User Manual
Distribution Date:
June 7, 2022
Network Distribution System - User Manual
NDS
Lorem ipsum
2
Distribution Date: May 10th, 2021
Copyright © 2021 by Adamson Systems Engineering Inc.; all rights reserved.
This manual must be accessible to the person operating this product. As such, the product owner must store it in a safe place
and make it available upon request to any operator.
Resale of this product must include a copy of this manual.
This manual can be downloaded from
User Manual
ADAMSON SYSTEMS ENGINEERING, Inc.
1401 Scugog Line 6, Port Perry
Ontario, Canada L9L 1B2
T: +1 905 982 0520, F: +1 905 982 0609
Website: www.adamsonsystems.com
https://adamsonsystems.com/en/support/downloads-directory
Network Distribution System - User Manual
NDS
Lorem ipsum
3
Contents
This symbol alerts the user that there are important operating and maintenance instructions in the
literature accompanying this appliance
This symbol alerts the user to the presence of voltages that can cause dangerous electric shock
This symbol alerts the user to the weight of the appliance that can cause muscle strain or back injury
This symbol alerts the user that the appliance can be hot to the touch and should not be touched
without taking care and instruction
Symbols 3
Safety & Warnings 4
Product Overview 5
Front View 5
Rear View 5
Specications 6
Network Redundancy 7
Combined Network Speaker Outputs 7
Symbols
Network Distribution System - User Manual
NDS
Lorem ipsum
4
Read these instructions and keep them available for future reference.
This manual can be downloaded from:
https://adamsonsystems.com/en/support/downloads-directory
Heed all warnings and follow all instructions.
Clean this product with a dry cloth only.
Never restrict the ventilation ports.
Protect the cabling from being walked on or pinched.
Onlyuseattachmentsand/oraccessoriesspeciedbyAdamsonSystemsEngineering.
Aqualiedtechnician must be presentduringtheinstallationanduseofthisproduct.
AdamsonSystemsEngineeringwillnot beliablefor damagescaused byany possible
misuse of this product.
Inspect the product before each use. If any sign of defect or damage is detected, imme-
diately withdraw the product from use for maintenance.
Referallservicingofthisproducttoqualiedservicepersonnel.
Do not open the unit. There are no user serviceable parts inside this product. Failure to
comply voids warranty.
Do not install this product in wet or humid locations.
Do not install this product near heat sources such as radiators, heat registers, stoves, or
other apparatus that produce heat.
Safety & Warnings
Network Distribution System - User Manual
NDS
Lorem ipsum
5
Product Overview
FIBRE IN / THRU
P1 P2
P2 P1
S1 S2
L1
L4
A1-1 L2
L5
A1-2
A2-2
A1-3
A2-3
L3
L6
A2-1
S2 S1
ANALOG 1 OUTPUT
ANALOG 2
RJ45 IN/THRU
NETWORK DISTRIBUTION SYSTEM
ADAMSON SYSTEMS ENGINEERING
www.adamsonsystems.com
MADE IN CANADA FABRIQUÉ AU CANADA
Serial Sticker Here
OUT 1 OUT 2 OUT 3 PRI
SEC
PRI
SEC
OUT 5 OUT 6OUT 4
Front View
Rear View
Dimensions
PrimaryLANIns
SecondaryLANIns
FIBRE IN / THRU
P1 P2
P2 P1
S1 S2
L1
L4
A1-1 L2
L5
A1-2
A2-2
A1-3
A2-3
L3
L6
A2-1
S2 S1
ANALOG 1 OUTPUT
ANALOG 2
RJ45 IN/THRU
NETWORK DISTRIBUTION SYSTEM
ADAMSON SYSTEMS ENGINEERING
www.adamsonsystems.com
MADE IN CANADA FABRIQUÉ AU CANADA
Serial Sticker Here
OUT 1 OUT 2 OUT 3 PRI
SEC
PRI
SEC
OUT 5 OUT 6OUT 4
Spk. Out
4
Spk. Out
1
Spk. Out
5
Spk. Out
2
Spk. Out
6
Spk. Out
3
XLR Outs 1
XLR Outs 2
XLR In 1
XLR In 2
PrimaryLanInstoAVB
enabled primary Switch
Secondary Lan Ins to
AVBenabledsecondary
Switch
Spk. Out
1 Prim.
Spk. Out
1 Prim.
Spk. Out
2 Prim.
Spk. Out
2 Prim.
Spk. Out
2 Prim.
Spk. Out
2 Prim.
Spk. Out
1 Sec.
Spk. Out
1 Sec.
Spk. Out
2 Sec.
Spk. Out
2 Sec.
Spk. Out
2 Sec.
Spk. Out
2 Sec.
483 mm / 19 in
257 mm / 10.1 in
88 mm / 3.46 in
Network Distribution System - User Manual
NDS
Lorem ipsum
6
Product Overview
Specications
The Network Distribution System (NDS) serves as the central patch bay for signal distribution to
CS-Seriesloudspeakersandotherrackmountedequipment,bypackagingmultipledigitalandan-
alog signals.
OpticalCON™ and etherCON™ connections on the front panel take input from the primary and sec-
ondaryLAN.TheseindividualLANsarethencombinedintoasinglecablecarryingredundantnet-
worked audio to the loudspeaker system.
TwoanalogsignalscanbedistributedbytheNDSviaXLRconnectorsonthefrontpanel.Eachan-
alog signal is split to three XLR connectors.
The rear panel of the NDS includes LC2 Fiber Optic and etherCON™ connections for sending pri-
maryandsecondaryLANtotwoAVB-enabledswitches,aswellassixprimaryandsixsecondary
etherCON™connectionsforAVBnetworkreturnsfromtheswitches.
TheNDSisapassivecablingpatchbay.ForfullfunctionalitytwoexternalAVBMilanenabledswitch-
es are necessary.
Network Distribution System - User Manual
NDS
Lorem ipsum
7
Network Redundancy
3
4
2
1
7
8
6
5
3
4
2
1
7
8
6
5
3
4
2
1
7
8
6
5
PRIMARY
LAN
COMBINED
SPEAKER
OUTPUT
SECONDARY
LAN
Combined Network Speaker Outputs
Splittingthe1Gbit/snetworkintotwo100Mbit/screatesaprimaryandsecondarynetwork.Bothnet-
worksarecombinedontheNDSspeakerouputs.EachnetworkconnectoronCS-Seriescabinetsisusing
two100Mbit/sswitchportsprocessingthereceiveddata,allowingforfullredundancyonasinglecable.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Adamson Network Distribution User manual

Type
User manual

Adamson Network Distribution is a central patch bay for signal distribution that packages multiple digital and analog signals to CS-Series loudspeakers and rack-mounted equipment. OpticalCON™ and etherCON™ connections take input from the primary and secondary LAN, combining them into a single cable for redundant networked audio to the loudspeaker system. Two analog signals can be distributed via front-panel XLRs, each split to three XLR connectors.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI