  • Hello! I am an AI chatbot trained to assist you with the American Dryer ADA-RK Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ADA-RK RECESS KIT INSTALLATION INSTRUCTIONS
(For use with all GX, GXT, & EXT hand dryers)
step-01_hardware
10/19/2012 Jay Harnish
STEP 1.
Fig. 1
Verify all hardware is present.
(1) Stainless steel recess box
(4) #8 x 1-1/2” stainless steel wood screw
(4) #10 flat washer
(4) #10-32 nut w/ nylon insert
step-03_recess kit_install
10/19/2012 Jay Harnish
STEP 3.
Fig. 3
Insert the recess box into the rough
wall opening. Run electrical through
conduit entrance as shown. Using the
provided wood screws, secure recess
box to wall studs as shown in figure 3.
DISCONNECT POWER BEFORE INSTALLING
DESUNA LA ELECTRICIDAD ANTES DE HACER REPARACIONES
WARNING:
14
1
2
"
19
1
2
"
"X"
TO
FINISHED
FLOOR
ROUGH
WALL
OPENING
1
7
8
"
3
3
4
"
"X"
Men
35 3/8"
Women
33 3/8"
Children
23 3/8" - 33 3/8"
Disabled
27 3/8"
step-02_rough opening
10/19/2012 Jay Harnish
STEP 2.
Fig. 2
Begin with a 14-1/2” W x 19-1/2” H
rough wall opening framed on all sides.
Make sure the opening is the correct
distance above the floor. Refer to the
chart below for mounting heights.
14
1
2
"
19
1
2
"
"X"
TO
FINISHED
FLOOR
ROUGH
WALL
OPENING
1
7
8
"
3
3
4
"
"X"
Men
35 3/8"
Women
33 3/8"
Children
23 3/8" - 33 3/8"
Disabled
27 3/8"
step-02_rough opening
10/19/2012 Jay Harnish
14-1/2”
19-1/2”
X
TO
FINISHED
FLOOR
3-3/4”
1-7/8”
step-05_dryer into recess kit
10/19/2012 Jay Harnish
step-06_cover on dryer
10/19/2012 Jay Harnish
STEP 4.
STEP 5.
Fig. 4
Fig. 5
Remove the hand dryer cover and
place dryer on the 4 mounting
studs. Secure using (4) #10 flat
washers and (4) #10-32 nuts.
Connect electrical wires to dryer
per the dryer schematic.
Place cover on dryer and
secure with (2) tamper proof
security screws (included
with dryer). Turn power on
at breaker and test.
AMERICAN DRYER, INC.
33067 INDUSTRIAL ROAD, LIVONIA, MI 48150, U.S.A.
Telephone (734) 421-2400 • Fax (734) 421-5580
www.americandryer.com • Email: sales@americandryer.com
Revised November 2012
DISCONNECT POWER BEFORE INSTALLING
DESUNA LA ELECTRICIDAD ANTES DE HACER REPARACIONES
WARNING:
/