GROHE Automatic 2000 19 605 User manual

Category
Sanitary ware
Type
User manual
................ 18
...........12
Sida.......7
D
Seite.....1
NL
PL
GB
S
UAE
F
DK
GR
E
N
CZ
I
FIN
H
Page.....2
Page.....3
Página..4
Pagina...5
Pagina...6
Side.......8
Side......9
Sivu ....10
Strona. 11
Σελιδα.13
Strana .14
Oldal ...15
P
Página.16
Sayfa.......17
TR
RUS
SK
Strana...... 19
19 604 mit Basic- (Trend-) Griff
97.752.131/ÄM 21 109/10.99
19 605 mit Basic- (Clova-) Griff 19 619 mit Trend-Griff
Linie EuroplusAutomatic 2000
................ 18
...........12
Sida.......7
D
Seite.....1
NL
PL
GB
S
UAE
F
DK
GR
E
N
CZ
I
FIN
H
Page.....2
Page.....3
Página..4
Pagina...5
Pagina...6
Side.......8
Side......9
Sivu ....10
Strona. 11
Σελιδα.13
Strana .14
Oldal ...15
P
Página.16
Sayfa.......17
TR
RUS
SK
Strana...... 19
977521.book : t97752.fm Seite 1 Montag, November 29, 1999 9:02 AM
I
1
A
A
2
B
B
3 4
Please pass these instructions on to the end user of the fitting.
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Bitte diese Anleitung an den Benutzer der Armatur weitergeben!
19 604
19 605
19 619
kl977521.fm Seite 2 Freitag, November 26, 1999 1:36 PM
II
AUS
( ) =
NZ
( ) =
AUS
NZ
kl977521.fm Seite 3 Freitag, November 26, 1999 1:36 PM
2
GB
Installation to finished stage
- Plaster and tile the wall, excluding the area occupied by the
mounting template. Seal any apertures in the wall so that they
are watertight to spray water.
Tiles laid in mortar should be pointed so that the joint is
tapered towards the outside.
Seal prefabricated walls with a permanently plastic
compound.
- Remove the mounting template, and install sleeves, see fig. [1].
Flush out the pipelines.
Reversed union (hot on right - cold on left).
Replace thermoelement (G), see replacement parts fold-out
page II, ref. No.: 47 282 (1/2).
- Unscrew and remove non-return valve (A), see fig. [2].
- Insert flushing plug (B) in vacant non-return valve aperture, see
fig. [3].
- Open the hot and cold water supplies and flush out the
thermostatic mixer thoroughly.
- Close the hot and cold water supplies, remove plug (B) and
install non-return valve (A).
- Secure escutcheon with screws, see Fig. [4].
If the thermostat has been installed at too great a depth, this
can be adjusted by 27.5mm with an extension set (see fold-out
page II, ref. No. 47 261).
If the thermostat has been installed at too shallow a depth, this
can be adjusted by 20mm with an compensation ring (see fold-out
page II, ref. No. 08 935 or 08 936).
Installation of the flow control knob and adjustment of the
economy stop, see Figs. [5] to [7].
The flow rate is limited by the economy stop (M) supplied,
see Fig. [5].
To install the flow control knob, proceed as follows:
1. Close the ceramic headpart by turning clockwise.
2. Install the economy stop (M) in the desired position, see Fig. [5].
For possible settings, see Fig. [6].
3. Install splined adapter (L) and flow control knob (K) with
economy button (N) pointing to the right.
Install screw (H) and cap (I), see Fig. [7].
If a higher flow rate is desired, the stop can be overridden by
depressing the economy button (N), see Fig. [7].
Adjustment
Installation of the thermostat knob and temperature
adjustment, see figs. [8] to [10].
Before the mixer is put into service if the mixed water
temperature measured at the point of discharge varies from the
specified temperature set on the thermostat.
After any maintenance operation on the thermoelement.
1. Open the shutt-off valve and check the temperature of the water
with a thermometer, see fig. [8].
2. Turn the adjusting nut (R) clockwise or anticlockwise until the
water temperature reaches 38 °C, see fig. [8].
3. Install thermostat knob (C) in such a way that the 38 °C mark on
the knob coincides with the mark (F) on the wall plate, then
tighten screw (E) securely, see fig. [9].
4. Install cap (D), see Fig. [10].
Temperature limitation
The safety stop limits the temperature range to 38 °C.
If a higher temperature is desired, the 38 °C stop can be overridden
by pressing in the safety stop.
Prevention of frost damage
When the domestic water system is drained, thermostat mixers
must be drained separately, since non-return valves are installed in
the hot and cold water connections.
The complete thermostat assemblies and non-return valves must
be unscrewed and removed.
Maintenance
For maintenance, see fold-out page II.
Shut off hot and cold water supplies.
I.Thermoelement
1. Pull off or unscrew and remove cap (D) for thermostat knob.
2. Remove screw (O) and pull off thermostat knob (C).
3. Pull off or unsrew cap (T) for shut-off knob and remove
screw (U).
4. Pull off shutoff knob (W).
5. Remove screws (V) and escutcheon.
6. Remove adjusting nut (R).
7. Pull off stop ring (S).
8. With a 24mm open-ended spanner, unscrew and remove
thermoelement (G).
II.Non-return valve
1. Proceed as for maintenance of thermoelement, points 1 - 7.
2. Unscrew and remove non-return valve (Y) with 17mm socket
wrench.
III.Ceramic headpart
1. Proceed as for maintenance of thermoelement, points 1 - 7.
2.Unscrew and remove sleeve (P).
3. With a 17mm open-ended spanner, unscrew and remove
ceramic headpart (Z).
Inspect and clean all parts, replace if necessary and grease with
special valve grease (ref. No. 18 012).
Replacement parts, see fold-out page II ( * = special accessories).
Reassemble in the reverse order. Use only genuine Grohe
replacement parts.
Readjustment is necessary after every maintenance operation on
the thermoelement (see Adjustment).
Care
For directions on the care of this thermostat mixer, please refer to
the accompanying Care Instructions.
977521.book : i97752gb.fm Seite 2 Montag, November 29, 1999 9:02 AM
III
M
5
6
N
L
K
H
I
7
38 C
R
8
C
F
E
9
D
10
977521.book : kr97752.fm Seite 11 Montag, November 29, 1999 9:02 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

GROHE Automatic 2000 19 605 User manual

Category
Sanitary ware
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI