Rev: 06/10
Part: 7000
11100 E. 45th Avenue • Denver, CO 80239 • Phone: 1. 866. PURE. ICE • Fax: 303. 371. 6296 • www.iceomatic.com
Ice. Pure and Simple
GEMPEARLICE®MAKER
GEMPEARLICE®MAKER
Air Cooled
Please note: air-cooled units require 6" (152 mm)
clearance for air intake and exhaust.
A. Ice maker potable water in, ⁄" FPT.
B. Ice maker water out, ⁄" FPT.
C. Electrical inlet.
Rear View Air Cooled
NOTES:
Number of Wires: 3 (including ground)
Approx. Shipping Weight lbs (kg): GEMA 205 (93) • GEMW 220 (110)
Refrigerant Type: RA
Specifications
Water Cooled
A. Ice maker water in, ⁄" flare.
B. Ice maker water out, ⁄" FPT.
C. Electrical inlet.
D. Condenser water in, ⁄" (water cooled only).
E. Condenser water out, ⁄" (water cooled only).
Rear View Water Cooled
2.3" (58 mm)2.3" (58 mm)
2.1" (53 mm)2.1" (53 mm)
5.25" (133 mm)5.25" (133 mm)
9.5" (241 mm)9.5" (241 mm)
3" (76 mm)3" (76 mm)
A.
C.
B.
4.5" (114 mm)
20.8" (528 mm)
12.4" (315 mm)
5.25" (133 mm)
3" (8 mm)
1.6" (41 mm)
3.8" (97 mm)
2.6" (66 mm)
4.7" (119 mm)
9.9" (252 mm)9.9" (252 mm)
14.25" (362 mm)14.25" (362 mm)
C.
A.
D.
E.
B.
Model Number Cond. Unit
Ice Production
per 24hrs
Water Usage
gallons per 100 lbs (45 kg) of Ice
90°F (32°C) air/70°F (21°C) water
kWH Used
per 100 lbs
(45 kg) of ice @
90°F (32°C) air/
70°F (21°C) water
Voltage
Characteristics
Min.
Circuit
Ampacity
Fuse
Size
Approx.
BTUs
per hour**
70°F (21°C) air/
50°F (10°C)
water lbs (kg)
90°F (32°C) air/
70°F (21°C)
water lbs (kg)
Potable Condenser
GEMA Air 464 (210) 354 (161)
12.0
- 5.31
115/60/1
16.0
20 5,600
GEMW Water 508 (230) 429 (195) 68.5 4.11 14.4
**BTUH is calculated F Evaporator, F Condensing, and PSIG.
Operating Requirements
MAXIMUM
60 Hz
AmbientTemp. Range Air
50˚F (10˚C)
100˚F (38˚C)
WaterTemp.
40˚F (4.4˚C)
Water Pressure
20 PSIG (1.4 BAR) 120 PSIG (8.3 BAR)
MINIMUM
Dimensions
ALLMODELS
W x D x H (in.) 21 x 24 x 27
W x D x H (mm) 533 x 610 x 686
Air In– Front
Air Out
21"
(533 mm)
24"
(610mm)
27" (686 mm)