  • Hello! I am an AI chatbot trained to assist you with the Everbilt C633WHD34 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
TECHNICAL BULLETIN
NIBCO Technical Services • Phone: 1.888.446.4226 • Fax: 1.888.336.4226
1
NIBCO INC.
WORLD HEADQUARTERS
1516 MIDDLEBURY ST.
ELKHART, IN 46516-4740
USA
PHONE: 574.295.3000
FAX: 574.295.3307
WEB: www.nibco.com
Review Date: 01/18/2012
Original Date: 06/24/1996
Document ID: NTB-0696-04
NIBCO
®
Copper Unions
“Ground-Joint” Seal Preparation for Copper/Bronze Unions
1.) Make sure the ground-joint area is free of nicks and scratches.
2.) Spray the ground-joint area with a silicone spray or beeswax to enhance seating.
3.) Recommended torques (for ground-joint seal):
½” (nominal) unions – 35 ft./lbs. (minimum)
¾” (nominal) unions – 60 ft./lbs. (minimum)
1” (nominal) unions – 70 ft./lbs. (minimum)
1 ¼” (nominal) unions – 70 ft./lbs. (minimum)
1 ½” (nominal) unions – 80 ft./lbs. (minimum)
2” (nominal) unions – 80 ft./lbs. (minimum)
4.) Make sure alignment of line does not put lateral stress on the ground-joint seal.