US Stove DV21N Installation guide

Type
Installation guide

This manual is also suitable for

Page 1
TESTED &
LISTED BY
OMNI-TEST LABORATORIES, INC
REPORT NO.:
215-S-31-4
PORTLAND
OREGON, USA
US
C
MODELS
DV8 (N,L)
DV14 (N,L)
DV21 (N,L)
NEED HELP ?
DO NOT RETURN THIS PRODUCT TO THE
STORE WHERE YOU PURCHASED IT.
If you have questions about assembling or
operating this appliance or if it seems defective
or parts are missing or replacement parts
required:
Please contact our Customer Support
1-800-750-2723
Page 2
Heater ............................
Page 3
610 m
610 m
MDV8
MDV8
MDV8
MDV8
MDV14
MDV14
MDV14
MDV14
MDV21
MDV21
MDV21
MDV21
The efficiency rating of the appliance is
a product thermal efficiency rating
determined under continuous operating
conditions and was determined
independently of any installed system.
or
/NG
/NG
Propane/
/NG
/NG /NG/LP /LP
Page 4
MDV8
MDV14
MDV21
12 15/64”
19 39/64”
25 19/32”
5 1/32” (MDV8-MDV14)
7 1/32” (MDV21)
24 5/64”
Do not use this appliance if any part has been under water. Immediately call a qualified technician to inspect
the appliance and to replace any part of the control system and any gas control which has been under water.
Page 5
* This installation information applies in the USA, for Canadian
installation refer to page 7 of this manual
*
(For U.S. vent terminal installations)
Page 6
4.
Clearance above grade, veranda,
porch, deck, or balcony
12 inches (30cm)
Clearance to window or door that may
be opened
6 inches (15 cm) for appliances <
10,000 Btuh (3 kW), 9 inches (23 cm)
for appliances > 10,000 Btuh (3 kW)
and < 50,000 Btuh (15 kW), 12 inches
(30 cm) for appliances > 50,000 Btuh
(15 kW).
Clearance to permanently closed
window
Vertical Clearance to ventilated soffit
located above the terminal within a
horizontal distance of 2 feet (61 cm)
from the center line of the terminal
Clearance to unventilated soffit
Clearance to outside corner.
Clearance to inside corner.
Clearance to each side of center line
extended above meter/regulator
assembly.
Clearance to service regulator vent
outlet.
Clearance to nonmechanical air supply
inlet to building or the combustion air
inlet to any building or other appliance.
6 inches (15 cm) for appliances <10,000
Btuh (3 kW), 9 inches (23 cm) for
appliances > 10,000 Btuh (3 kW) and <
50,000 Btuh (15 kW), 12 inches (30 cm)
for appliances > 50,000 Btuh
(15 kW).
Clearance to mechanical air supply
inlet.
Clearance above paved side walk or
paved driveway located on public
property.
Clearance under veranda, porch,
deck or balcony.
3 feet (91 cm) above if within 10 feet
(3 m) horizontally.
Canadian Installations¹
6 inches (15 cm) for appliances <
10,000 Btuh (3 kW), 12 inches (30
cm) for appliances > 10,000 Btuh
(3kW) and <100,000 Btuh (30kW), 36
inches (91 cm)for appliances >
100,000 Btuh (30kW).
3 feet (91 cm) within a height 15 feet
(4.57 m) above the meter/regulator
assembly.
6 inches (15 cm) for appliances < 10,000
Btuh (3 kW), 12 inches (30 cm) for
appliances > 10,000 Btuh (3kW) and
< 100,000 Btuh (30kW), 36 inches (91
cm) for appliances > 100,000 Btuh
(30kW).
6 feet (1.83 m)
7 feet (2.13m)
12 inches (30cm)
3 feet (91 cm)
3 feet (91 cm)
3 feet (91 cm)
12 inches (30cm)
2
Page 7
Page 8
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both
dwellings.
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
Page 9
MDV8
MDV14
MDV21
Do not connect this appliance to a chimney flue serving a separate
solid fuel appliance.
Page 10
7 1/4” 1./4”
5/8
6 1
./2
1 3/8
3 7/8
3 1
./2
MDV8
MDV14
MDV21
HEATER
8 1./2
1 3/8 3/8”
4 7/8
Page 11
Pilot Hole
Wall Bracket
Template
3-1/2”
FLOOR LINE
Marking for
Flue Outlet
Hole
Marking for Wall Bracket
Mounting Holes - 4 Qty.
Marking for
Gas Inlet
Hole
3-1/2”
FLOOR LINE
9
3-1/2”
Page 12
Holes
10
Page 13
10
10
Page 14
10
Gases Outlet
Cap
Attach the gases outlet cap making sure that the threaded rod comes
through the center hole in the cap. Secure the gases outlet cap by
attaching the washers and the brass blind nut to the threaded rod using
a screwdriver, tightening to stabilize the vent kit.
Page 15
Electrode
Wires
Front
of Unit
Back
of Cabinet
heater
Page 16
Page 17
Page 18
Call our customer service at 1 800 750 2723.
Page 19
Call our customer service.
Page 20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

US Stove DV21N Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI