Roland M-300 User manual

Type
User manual

This manual is also suitable for

1
Functionality added in M-300 version 1.01
Engineer’s Monitor function has been added to the M-48 Manager (
p. 1).
M-48 mix option has been added (
p. 2).
Number of V-LINK remote sources has been increased to 16.
Pink noise and White noise have been added to the oscillator.
Input/output patchbay operation via the RS-232C has been added.
For more information, refer to “V-Mixer RS-232C Reference.”
By designating an M-48 located beside the engineer as the Engineer’s Monitor, he/she can monitor and control the mix of any musician’s M-48 unit from the
Engineer’s Monitor.
You cannot use the Engineer’s Monitor function if the system program version of the M-48 is prior to 1.01.
On the Engineer’s Monitor, you cannot monitor the AUX IN or the AMBIENT MIC on the musician’s side.
Using the Engineer’s Monitor function with the M-48 Personal Mixing System
1.
Press [MONITOR] to access the MONITOR screen.
2.
Press [F8 (M-48 MANAGER)] to access the M-48
MANAGER popup.
fig.M48_Manager.eps
3.
In the M-48 list, move the cursor to the desired M-48 unit
and press [F8 (SET AS ENG MON)].
A message will ask you to confirm the operation.
4.
Press [F8 (SET)] to specify the selected M-48 unit as the
Engineer’s Monitor.
fig.M48_EngMon.eps
5.
To monitor a musician’s mix, select the corresponding M-
48 unit in the M-300’s screen.
6.
You can also control the musician’s group mix from the
Engineer’s Monitor.
To control the musician’s mix from the Engineer’s Monitor, the
MONITOR-ONLY select button on the M-48 ENGINEER’S MONITOR SETUP
popup must be cleared.
The solo function on the M-48 works independently on the musician’s
side and engineer’s side. Therefore, solo operation on engineer’s side
does not affect the musician’s side.
The M-48 unit specified as the Engineer’s Monitor will be registered to
the M-300’s system settings, and it can be saved to the M-300’s project
file. When you initialize the M-300’s system settings, the Engineer’s
Monitor setting will be cleared. You can load the Engineer’s Monitor
settings by loading the system settings from the M-300’s project file you
saved.
The following knobs work independently on the engineer’s side and
musician’s side. The position of each knob on the musician’s side are
displayed on the M-48 SETUP popup:
[AUX IN] knob
[AMBIENT MIC] knob
LINE OUT [VOLUME] knob
[BASS] knob, [TREBLE] knob
[LIMITER] knob
PHONES [VOLUME] knob
fig.M48_Setup02_Guide.eps
Specifying an Engineer’s Monitor unit
M-300_v101Added_e.book 1 ページ 2010年9月27日 月曜日 午後1時53分
2
Functionality added in M-300 version 1.01
1.
Access the M-48 MANAGER popup.
2.
Press [F6 (ENG MON SETUP)].
fig.M48_EngMonSetup.eps
The M-48 ENGINEER’S MONITOR SETUP popup will appear.
You can set the following items:
SOLO MODE select button
LAYER select clears SOLO
LINE OUT MONO select button
MONITOR-ONLY select button
By checking the MONITOR-ONLY select button, the Engineer’s
Monitor works just for audio monitoring, and it does not control the
musician’s mix.
The LINE OUT SOURCE select button and the LINE OUT LPF select button
follows the settings of the musician’s side.
MEMORY operation on the Engineer’s Monitor is not allowed.
1.
Access the M-48 MANAGER popup.
2.
Press [F8 (ENG MON SETUP)].
fig.M48_EngMonSetup.eps
The M-48 ENGINEER’S MONITOR SETUP popup will appear.
3.
Press [F8 (RELEASE ENG MON)].
A message will ask you to confirm the operation.
4.
Press [F8 (RELEASE)] to release the ENGINEER’S
MONITOR.
Editing the Engineer’s Monitor
preference settings
Releasing the Engineer’s Monitor
The MIX OPTION has been added to the M-48 Source Assign popup. By checking the “MIX only Assigned Sources” select button, only sources assigned to a
group will be mixed to the M-48’s MAIN buses.
You cannot check the “MIX only Assigned Sources” select button if the system program version of the M-48 is prior to 1.01.
Setting the M-48 mix option
1.
Access the M-48 MANAGER popup.
2.
In the M-48 list, move the cursor to the desired M-48 unit
and press [F2 (SETUP)].
fig.M48_Setup.eps
The M-48 SETUP popup will appear.
3.
Press [F4 (SOURCE ASSIGN)].
fig.M48_SrcAssign.eps
The M-48 SOURCE ASSIGN popup will appear.
4.
Move the cursor to the MIX only Assigned Sources select
button in the MIX OPTION, and press [ENTER].
A message will ask you to confirm the operation.
5.
Press [F8 (CHANGE)] to check/uncheck.
1PS
M-300_v101Added_e.book 2 ページ 2010年9月27日 月曜日 午後1時53分
  • Page 1 1
  • Page 2 2

Roland M-300 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI