DKS 6004 Quick start guide

Category
Gate Opener
Type
Quick start guide
Drive Arm
Linking Arm
Arm Assembly
Install the gate
attachment
bracket to gate.
Lockpin
Lockpin
Retaining Ring
Spacing
Washers
QUICKSTART “BASIC” GUIDELINES FOR MODEL 6004 - FOR GATES UP TO 8 FEET, 300LBS AND “OPENING TO THE INSIDE”
Copyright 2021 DoorKing
®
, Inc. All rights reserved.
Thru-Bolt
Note: The mounting bracket and motor can
be flipped for right-side opening direction.
Remove cover and 2 thru-bolts to remove
and install the mounting bracket.
Note: Lock and unlock directions will be reversed
when motor is in the right-side orientation.
Manual Release
Right-Side Orientation
Left-Side Orientation
D O O R K I N G
Motor
Cover
Mounting
Bracket
Note: Linking arm must be in the center hole of
the gate attachment bracket.
Opens to the
Inside
Position of Operator and Arms
Operator
Disassembly
Installing Mounting Bracket and Gate Attachment Bracket
1234567
1234567
C
B
A
90°
Linking Arm
“A” inches “B” inches C max. inches
Gate Attachment Bracket
2.50 - 4.25
4.25 - 6.25
6.25 - 8.25
8.25 - 10.25
10.25 - 12.25
12.25 - 14.00
28.75
28.25
28.00
27.25
27.00
26.25
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
DOORKING
DOORKING
DOORKING
Support Bar must be used if the operator
is mounted in the middle of the gate and span the
entire length of the gate to support the gate
pickets. The pickets will bend if not supported.
Top
Middle
Bottom
Left-Side Position Right-Side Position
Coaxial
Cable
Antenna
(Not
Supplied)
Operator
Cable
Power
Loops
Unlock Lock
Unlock
Lock
Mounting Options
Attach mounting bracket to pilaster or wall with four (4) #10
screws and suitable expansion hardware (Not supplied).
Left-Side
“Bottom”
Position
shown.
1 5/8”
Brackets MUST be
installed level!
Weld gate attachment bracket to gate or
use two (2) suitable screws (Not supplied).
Brackets MUST be securely attached.
Extreme force will be exerted on
brackets during normal gate cycling.
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
Limit Switch Adjustment
Limit LEDs
Slow Down LEDs
Circuit board power must be ON when adjusting the limit rings, LEDs will
light while turning the limit rings.
4302
4302
Arms MUST be
installed level!
6004-066-K-1-21
Brown wire
Blue wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
NOT USED
7-Wire
Operator
Cable
5” or less
21”
Typical
27.5”
Max
Photo Sensors Height
Close Beam
Open Beam
Open Beam
Close Beam
Reversing Edge
Photo Sensor
Photo Sensor
Sensor mounted
just below actuator
arm cable.
Gate Opened
Gate Closed
Outside
Property
Inside
Property
Single operator connects to
PRIMARY connection ONLY
on the 115 VAC OR Solar
control box circuit board.
1
7
8
6
5
4
3
2
PRIMARY
4302
The 6004 is intended for installation only on swing gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to
6004 Actuator Arm and Control Box Mounting manual, 115 VAC or Solar Control Box Wiring/Owner’s manuals.
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY.
Visit
www.dkslocator.com
to find a professional installing and servicing dealer in your area.
Gate Closed
Left-Side Right-Side
Securely mount a control
box near the actuator arm
with appropriate hardware
(not supplied).
Control Box
115 VAC
or Solar
Power
Input
Opening Direction DIP-Switch 1 (SW 1)
Refer to YOUR chosen 115
VAC OR Solar powered
control box manuals for
complete DIP-switch settings.
DO NOT
cycle operator
before limit switches and
DIP-switches have been
adjusted, damage could
occur to gate and operator.
Limit
Slow
Down
Slow Down
Limit
Top Limit
Ring
Bottom
Limit Ring
Slow
Down
Thru-Bolt
Thru-Bolt
Manually move the gate to the desired
open or closed position. Loosen the limit
screws and slowly rotate the limit rings
until the LIMIT LEDs on the circuit board
light up.
Reversing Edge
is mounted
along ENTIRE
end of gate.
Wiring to Circuit Board
Potential
Entrapment
Area
Note: Only 1 monitored Device can be connected for each
cycling direction. An OPTIONAL Expansion Kit (sold
separately) will allow connection for additional devices.
Refer to YOUR chosen 115 VAC OR Solar powered control
box manuals to wire entrapment protection devices.
Open to the Outside
- Refer to 6004 manual
“Open to the Inside” Installation
Note: Refer to 6004 manual for “Open to the Outside” installation.
Open
to the
Inside
The operator MUST OPEN GATE upon initial
power up and OPEN command.
If the operator closes gate after giving open
command, shut off power and reverse this
switch setting otherwise operator will NOT
function correctly.
External
Entrapment
Protection
Devices
Entrapment Protection must be
provided for the gate system
where the risk of entrapment
or obstruction exists. The
operator will not run without
one or more monitored type B1
or B2 entrapment protection
devices in EACH entrapment
area.
UL 325 August
2018 Standard
OFF setting.
Opens clockwise.
ON setting.
Opens counter-clockwise.
Note: If factory wired jumpers are on
operator terminal, they MUST be removed.
Connect to the 115 VAC OR Solar control box circuit board.
SW 1
1
ON
2 3 4 5 6 7 8
  • Page 1 1

DKS 6004 Quick start guide

Category
Gate Opener
Type
Quick start guide