Paxton OEM PROXIMITY panel mount reader - Hitag 2 - Clock and Data Quick start guide

Type
Quick start guide
Ins-30087 OEM PROXIMITY panel mount reader - Hitag 2 - Clock and Data
18/08/2011
Open collector
Pull directly to
0V to light LED
Suitability
Security-sensitive doors
Wet environments
Readers mounted together
Mounted on metal surface
between readers
300 mm
Fitting
Wiring
+12V DC
Red LED
Amber LED
Green LED
Data
Clock
Not required
0V
-20 °C
+55 °C
IPX7
9V DC 14V DC
110 mA
125 kHz
600 µs
58 mm 58 mm
17 mm
40 mm 40 mm
49 mm 49 mm
PROXIMITY panel mount reader - Hitag 2 - Clock and Data
Window assembly
Instruction set
Output format
Tclk
Tclklo
Ts u
Thold
Da
Data 0
Data 1
Data Period ( Tclk ) 600 µs
Data Setup Time (Tsu) 200 µs
Data Clock Low (Tclklo) 200 µs
Data Hold Time (Thold) 200 µs
Readers can be extended using Belden CR9540 10-core
overall screened cable to a maximum of 100 metres.
Cable extensions
Voltage
Clock and data bit period
Carrier frequency
Specications
Operating temperature
Electrical
Environment
Dimensions
Min
Max
Width
Height
Depth
Current
Cable length
Waterproof
Panel mount reader
Window size
Mounting holes - 3.7 mm dia - square formation
See front page for position
Max
Min
Outdoor Use
5 metres
Contents in box