CAUTION...............WARNING...............IMPORTANT
USE ONLY PETERSON REAL FYRE BURNERS AND VALVES WITH THIS REAL FYRE LOG SET.
Important: Adequate ventilation is absolutely
necessary. Adequate spacing
between the logs is NECESSARY
and MUST be maintained. Some
carbon build up (sooting) may occur
where fl ames strike the logs. If carbon
build up (sooting) continues, correct
log placement before sooting becomes
worse.
This product is only warranted when used as part of a Robert H. Peterson Co. vented burner system.
WARNING: Use ONLY Peterson Real Fyre direct
vent inserts with this Real Fyre gas log
set. Failure to do so may result in
property damage or personal injury,
and will void listings, certifi cations,
and invalidate claims made to RHP.
Contact your local Real Fyre dealer if you
need more information.
This instruction contains log set and ember placement for these Real Fyre logs. You must position and
maintain the log layout as shown here to ensure proper operation of the direct vent insert. Incorrect log
installation could cause fl ame impingement and improper combustion, resulting in soot and/or excessive
by-products of combustion. DO NOT add any additional embers for this installation. Any additional embers
will cause unsafe operation. Use these logs only with a Peterson direct vent insert.
If you experience a continued accumulation of black carbon (soot) on your logs, the glass panel, or refractory
panels, it is an indication of incomplete combustion and you must correct the log placement as instructed
in this manual. If signifi cant sooting continues, stop using this gas log set.
Important: HANDLE LOGS WITH CARE AT ALL TIMES.
Please read these instructions completely and carefully.
L-A2-441REV 0 - 1803050715
LOG SET IMPORTANT INFORMATION
CAUTION...............WARNING...............IMPORTANT
USE ONLY PETERSON REAL FYRE DIRECT VENT INSERTS WITH THIS REAL FYRE LOG SET.
CHARRED MOUNTAIN BIRCH LOG PLACEMENT INSTRUCTIONS
DVL-30-2MB shown
This log set is to be installed along
with the glowing embers and bryte
coals that are supplied with your
direct vent insert.
2
CAUTION: Burn hazard! Logs will remain hot for some time after use.
If you need to reposition any log to maintain the proper layout,
use heat resistant gloves or allow logs adequate time to cool
before handling.
Failure to use Peterson burners and valves may result in a DANGEROUS
situation and in property damage, personal injury or even death; will void
listings and certifi cations; and will void any insurance coverage by R.H.
Peterson Co or our insurers.
WARNING: This gas log set is for use with R.H. Peterson Co burners
(and parts) ONLY.
L-A2-441
REV 0 - 1803050715
CAUTION: Burn hazard! Logs will remain hot for some time after
use. If you need to reposition any log to maintain the proper
layout, use heat resistant gloves or allow logs adequate time
to cool before handling.
Failure to use Peterson burners and valves may result in a DANGEROUS
situation and in property damage, personal injury or even death; will
void listings and certifi cations; and will void any insurance coverage
by R.H. Peterson Co or our insurers.
WARNING: This gas log set is for use with R.H. Peterson Co
burners (and parts) ONLY.
Failure to use Peterson direct vent inserts may result in a DANGEROUS
situation and in property damage, personal injury or even death; will
void listings and certifi cations; and will void any insurance coverage
by R.H. Peterson Co or our insurers.
WARNING: This gas log set is for use with R.H. Peterson Co
direct vent inserts ONLY.
3
Charred Mountain Birch Log Placement Instructions (25" model)
IV
I
II
III
V
DVL-25-2MB
PARTS LIST
All items for this log set are included in one (1) box.
CAUTION: Burn hazard! Logs will remain hot
for some time after use.
1
2
DVMBL-25BR
DVMBL-25BF
6
DVMBL-7
3
5
DVMBL-9
DVMBL-8T
1
Place the rear log (log #1) as shown. The bottom
of the log has two holes that align with two pegs
found on the burner.
Separate glowing embers
and place as shown here
Separate a portion of the glowing embers into
small pieces and evenly place them along the
rear and center burner ports as shown.
2
2
Place the left and right front log pieces (log #2)
as shown. The bottom of the logs each have two
holes that align with the pegs found on the burner.
Separate glowing embers
and place as shown here
(top view above front log)
Separate the remaining glowing embers into small
pieces and evenly place them along the front and
center burner ports as shown.
Separate bryte coals and
place as shown here
(top view above front log)
Separate the bryte coals into small pieces and
evenly place them above the front glowing embers
as shown.
4
DVMBL-11TY
4
Charred Mountain Birch Log Placement Instructions (25" model) (Cont.)
VI
VII
Place the left and middle top logs (logs #3 and
#4) as shown. The rear log has a notch to aid in
positioning the top logs.
Place the right and middle top logs (logs #5 and
#6) as shown. The logs below have notches to aid
in positioning the top logs.
5
6
4
3
During initial use, the logs will go through a curing process and will temporarily turn a darker
color. This will last for approximately 6-8 hours (of burn time); then the logs will return to their
original white color.
5
Charred Mountain Birch Log Placement Instructions (30" & 36" models)
IV
I
II III
V
CAUTION: Burn hazard! Logs will remain
hot for some time after use.
DVL-(30,36)-2MB
PARTS LIST
30" Charred Mountain Birch log set shown
1
2
3
7
5
4
30" - DVMBL-30BR
36" - DVMBL-36BR
30" - DVMBL-30BF
36" - DVMBL-36BF
All items for these log sets are included in one (1) box.
1
Place the rear log (log #1) as shown. The bottom
of the log has two holes that align with two pegs
found on the burner.
Separate glowing embers
and place as shown here
Separate a portion of the glowing embers into
small pieces and evenly place them along the
rear burner ports, ember screen, and front carry
over ports as shown.
2
2
Place the left and right front log pieces (log #2)
as shown. The bottom of the logs each have two
holes that align with the pegs found on the burner.
Separate glowing embers
and place as shown here
(top view above front log)
Separate the remaining glowing embers into small
pieces and evenly place them along the front and
center burner ports as shown.
Separate bryte coals and
place as shown here
(top view above front log)
Separate the bryte coals into small pieces and
evenly place them above the front glowing embers
as shown.
6
DVMBL-13
DVMBL-11
DVMBL-10
36"
DVMBL-12Y
30"
DVMBL-12
36"
DVMBL-11T
30"
DVMBL-8
6
Charred Mountain Birch Log Placement Instructions (30" & 36" models) (Cont.)
Place the left and middle top logs (logs #3 and #4)
as shown. The logs below have notches to aid in
positioning the top logs.
VI
VII
VIII
Place the right top log (logs #5) as shown. The log
below have notches to aid in positioning the top log.
Place the right top logs (logs #6 and #7) as shown.
The logs below have notches to aid in positioning
the top log.
4
3
7
5
For 36" models,
place logs
#6 and #7 as
shown in the
image to the
right.
36" models
6
7
6
During initial use, the logs will go through a curing process and will temporarily turn a darker
color. This will last for approximately 6-8 hours (of burn time); then the logs will return to their
original white color.
/