3.3 Water connection :
The appliance comes with a water supply hose requiring a ¾” BSP male
threaded connection at the mains water supply, upon installation and
commissioning all water joints must be checked for leaks).
3.3.1 Water supply restrictions :
Water supply constraints must be adhered to :
• Incoming water temperature
• 4°c minimum
• 55°c maximum
• Supply water dynamic pressure (air break machines, minimum water pressure
0.25 bar, all other parameters apply).
• 0 to 2 bar Rinse booster pump required
• 2 to 4 bar No modifications required
• 4 to 6 bar Flow restrictor required
• 6 bar plus Pressure reducing valve required
If the above requirements are not adhered to, the performance of the appliance
will be impaired
3.3.2 Drainage systems
Appliances are available as either gravity drain or pumped drain, upon
installation the waste hose and stand pipe must be configured as shown within
this manual, also all installations must be with a running / ‘P’ trap to ensure
hygiene, to identify your appliance see page 9 of this manual :
Drain pump machine
• Ø40mm (Ø1 ½”) standpipe required
• Standpipe must be 100 to 150mm
(4” to 6”) below the top of the
appliance.
• The end of the waste outlet hose in
the standpipe must not be lower
than the bottom of the door.
• The waste outlet hose must be a
loose fit within the standpipe.
Page 4
Bleeding of drain pump
After installation and once the tank is partially filled, i.e. before the 1st wash
cycle the drain system MUST be ‘BLED’, simply lower the drain hose into an
empty bucket and allow approximately 4 litres of water to flow out of the hose,
carefully return the hose to the stand pipe as shown above. Ensure any spillage
is cleaned before leaving the appliance.