Parts List
1. In-Wall Body/Assembly
2. Ceramic Cartridge
3. Splined Valve Stem
4. Lock-nut
5. Spline Extension
6. Screw
7. Wall Plate O-ring
8. Wall Plate
9. Flange Washer
10. Flange
11. Handle
12. Handle Screw
13. Handle Button
14. Hot Indicator
15. Push-it Wall Plate
16. Outlet
Optional Extras
For installations with a greater
inished wall depth:
20mm Extended Body
3606005200IW
For installations with minimal
inished wall depth:
Horizontal In-Wall Mounting Bracket
3612000100
Eccentric by Rogerseller
Wall Mixer with Outlet
Chrome
Other inishes available
Bath Outlet
3606013201
Basin Outlet
3606013301
1
14
15
16
2
3
4
5
6
7
8
9
10
11
12
13
Pre-Installation
Checklist
Flush to remove any foreign matter from
plumbing lines.
Ensure mixer is in the closed position during
installation and testing.
In-line ilters are recommended to ensure
clean low of water to the mixer.
Mounting
When mounting the body onto the wall frame,
take note of the dimensions shown so the
mixer is correctly positioned with the inished
wall.
Min/Max: 80100mm
Diameter hole: 4255mm
Mixer body must be installed level and
square to the wall with the outlet connection
horizontal to ensure correct handle
orientation.
Water Supply
Connect water supply to points as illustrated,
right. Do not apply heat to the mixer or
pipework connected near the mixer. Damage
to the ceramic cartridge caused by heat near
the mixer will void the warranty.
Note: Mixer in-wall must be installed level and square to the
inished wall.
In-wall supplied with a protective cover. Do Not remove
until all works complete and ready for handle itment.
Cold Inlet
G 1/2" BSP
Fixing Screw
Holes
Hot Inlet
G 1/2" BSP FI
Fixing Screw
Holes
Connection for Outlet
G 1/2" BSP MI
Installation
Step 1
Install the spline extension onto the valve
stem if not already done so.
Step 2
Trimming spline extension: Measure
2728mm from the inished wall and trim
spline extension at this inish point.
Step 3
Place the wall plate with O-ring over the body
making sure the "C" & "H" located correctly as
shown in diagram.
Valve Stem
Spline Extension
Screw
Finished Wall
Trim at nearest
cutting groove
towards wall
Measure
2728mm
Step 4
Place lange washer over the lange and
screw lange on the body through the wall
plate clockwise until the wall plate lush with
the inished wall, as shown.
To inished wall
80100mm
Wall Frame Finished Wall
Flange
Ø42mm
0.5–1mm Gap
Wall Plate
Handle
Ø60mm
Body
Installation
Step 5
Locate the handle and tighten handle screw
with 2.5mm allen key.
If the handle isn't horizontal, remove the
handle and mark both the valve stem and
spindle extension. Remove extension and
reposition by rotating one tooth at a time until
horizontal is achieved.
Tighten handle screw clockwise with 2.5mm
allen key supplied and push in handle button
until lush with handle.
Note: to remove handle, push the button into handle to
access screw.
Step 6
Apply the push-it wall plate to the outlet.
Screw the outlet onto the in-wall assembly
until level with the wall. Push the wall plate
up against the inished wall to complete the
installation.
Step 7
Prior to introducing mains supply it is
mandatory that lines are lushed.
Open handle in the mixed position - midway
between "C" & "H" and ensure the aerator is
removed from outlet.
Handle
Handle Screw
Handle Button
Horizontal
Push-it Wall Plate
Outlet
Templates
Plumbers Template (Mixer Orientation)
Ensure if pairing with outlet to note oset
nature of handle when roughing in.
Please refer to handle orientation and
template for oset location.
Tilers Template (Hole Cut Out)
3
3Oset Drill Hole
Key
3
3Oset Drill Hole
Key
44 (Hole Drill Out)
Minimum tolerances apply
rogerseller.com.au
Specifications
It is a requirement of state plumbing codes that licensed plumbers carry out all tapware installations.
All installations must comply with the relevant requirements of AS/NZS3500 and local plumbing
codes.
Pressure
Maximum Hydrostatic Pressure - 1000kpa
Recommended Maximum Hydrostatic Pressure - 500 kpa. (AS/NZS 3500)
Recommended Minimum Hydrostatic Pressure - 150 kpa.
Maximum Hydrostatic Pressure may be exceeded under test conditions only in accordance with AS/
NZS 3500. Where hydrostatic pressure exceeds the maximum stated above, pressure limiting valves
must be installed or warranty will be void.
Temperature
Maximum Water Temperature - 80°C
For optimum performance, Hot and Cold inlet water pressure should be equal.
Care and Maintenance
[1] Product should be inspected for surface damage prior to installation. [2] Cleaning and handling
of all inishes must be performed carefully. [3] Clean products using a soft cloth with warm soapy
water only. [4] Never use harsh detergents or abrasive cleaners as these will damage the product.
[5] Water marks can be removed from Matt Finishes with an application of a carnauba wax based
non-abrasive polish on a microibre cloth. [6] Do not use undue pressure when cleaning and wipe
in one direction only. [7] Contact with harsh chemicals such as hair dye, hair bleach etc will result
in damage to the inish. [8] Tapware should never be installed using acetone silicones. [9] Avoid the
use of wax based furniture creams as this can result in a build up of deposits which will detract from
the appearance. [10] Damage to inishes arising from improper installation or post installation use or
failure to observe the above care and cleaning instructions will void all warranty agreements.
Warranty
Rogerseller tapware, bathroom ittings and sanitaryware are covered by a ive (5) year warranty from
date ofpurchase. Forfullterms and conditions please refer to rogerseller.com.au
Dimensions are approximate. Information in this installation instruction is representative of the product available at
the time of printing. Due to our policy of continuous product development, the design and speciications depicted
are subject to change without notice. Please conirm all particulars with your client advisor prior to purchase.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

ROGERSELLER 3606013201 Eccentric Wall Mixer and Bath Outlet Chrome User manual

Category
Sanitary ware
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI