Lantronix UDS-10 User manual

Category
Networking
Type
User manual

This manual is also suitable for

Part Number 900-360
Revision A June 2004
UDS10
UDS100
User Guide
2
Copyright & Trademark
© 2004, Lantronix. All rights reserved. No part of the contents of this book may be
transmitted or reproduced in any form or by any means without the written permission
of Lantronix. Printed in the United States of America.
Ethernet is a trademark of XEROX Corporation. UNIX is a registered trademark of
The Open Group. Windows 95, Windows 98, Windows 2000, and Windows NT are
trademarks of Microsoft Corp. Netscape is a trademark of Netscape Communications
Corporation.
Contacts
Lantronix
15353 Barranca Parkway
Irvine, CA 92618, USA
Phone: 949-453-3990
Fax: 949-453-3995
Technical Support
Phone: 800-422-7044 or 949-453-7198
Fax: 949-450-7226
Online: www.lantronix.com/support
Sales Offices
For a current list of our domestic and international sales offices, go to the Lantronix
Web site at http://www.lantronix.com/about/contact/index.html
3
Disclaimer & Revisions
Operation of this equipment in a residential area is likely to cause interference, in
which case the user, at his or her own expense, will be required to take whatever
measures may be required to correct the interference.
Note: This product has been designed to comply with the limits for a Class A
digital device pursuant to Part 15 of FCC Rules. These limits are designed to
provide reasonable protection against such interference when operating in a
commercial environment. This equipment generates, uses, and can radiate
radio frequency energy, and if not installed and used in accordance with this
guide, may cause harmful interference to radio communications.
Changes or modifications to this device not explicitly approved by Lantronix will void
the user's authority to operate this device.
The information in this guide may change without notice. The manufacturer assumes
no responsibility for any errors that may appear in this guide.
Date Part No. Rev. Comments
6/04 900-360 A
Initial document combining UDS10 and UDS100 products.
4
Contents
Contacts 2
1: Using This Guide 8
Purpose and Audience________________________________________________ 8
Chapter Summary ___________________________________________________ 8
Additional Documentation _____________________________________________ 9
2: Introduction 10
Applications _______________________________________________________ 10
Application Examples________________________________________________ 10
Protocol Support ___________________________________________________ 12
Additional Features _________________________________________________ 12
Configuration Methods_______________________________________________ 12
Product Information Label ____________________________________________ 13
3: Getting Started 14
Installing the UDS __________________________________________________ 14
Required Information ________________________________________________ 15
Hardware Address_______________________________________________ 15
IP Address_____________________________________________________ 15
Assigning the IP Address and Related Network Settings ____________________ 16
DeviceInstaller__________________________________________________ 16
Serial Port Login ________________________________________________ 17
4: Configuring the UDS Using Web Manager 18
Accessing Web Manager _____________________________________________ 18
Using Web Manager ________________________________________________ 20
Example_______________________________________________________ 20
5: Configuring the UDS Using Telnet or the Serial Port 22
Using a Telnet Connection ________________________________________ 22
Using the Serial Port _____________________________________________ 23
Server Configuration (Network Configuration) _____________________________ 24
IP Address_____________________________________________________ 24
Set Gateway IP Address __________________________________________ 24
Netmask ______________________________________________________ 24
Change Telnet configuration password _______________________________ 25
DHCP Naming__________________________________________________ 25
Channel 1 Configuration (Serial Port Settings) ____________________________ 26
Baudrate ______________________________________________________ 26
I/F (Interface) Mode ______________________________________________ 26
Flow__________________________________________________________ 27
Port Number ___________________________________________________ 27
Connect Mode __________________________________________________ 28
Manual Connection ______________________________________________ 29
UDS10/UDS100 User Guide
5
Remote IP Address______________________________________________ 32
Remote Port ___________________________________________________ 32
Disconnect Mode _______________________________________________ 33
Flush Mode ____________________________________________________ 33
Pack Control ___________________________________________________ 34
Disconnect Time (Inactivity Timeout) ________________________________ 35
Send Characters ________________________________________________ 35
Telnet Terminal Type ____________________________________________ 35
Channel (Port) Password _________________________________________ 35
Expert Settings ____________________________________________________ 35
TCP Keepalive time in s __________________________________________ 36
ARP Cache timeout in s __________________________________________ 36
Security Settings ___________________________________________________ 36
Disable SNMP__________________________________________________ 36
SNMP Community Name _________________________________________ 37
Disable Telnet Setup_____________________________________________ 37
Disable TFTP Firmware Upgrade ___________________________________ 37
Disable Port 77FE (Hex) __________________________________________ 37
Disable Web Setup ______________________________________________ 37
Disable ECHO Ports _____________________________________________ 37
Enable Enhanced Password_______________________________________ 37
Factory Default Settings _____________________________________________ 38
Channel 1 Configuration Defaults ___________________________________ 38
Expert Settings Defaults __________________________________________ 38
Security Settings Defaults_________________________________________ 38
Exit Configuration Mode _____________________________________________ 38
6: Updating Firmware 39
Obtaining Firmware _________________________________________________ 39
Reloading Firmware ________________________________________________ 39
Using DeviceInstaller ____________________________________________ 39
Using TFTP____________________________________________________ 40
Using Another Unit ______________________________________________ 41
Using the Serial Port _____________________________________________ 41
7: Using Monitor Mode 43
Entering Monitor Mode Using the Serial Port _____________________________ 43
Entering Monitor Mode Using the Network _______________________________ 43
Using Monitor Mode Commands _______________________________________ 44
8: Troubleshooting and Contact Information 45
LEDs ____________________________________________________________ 45
Problems and Error Messages ________________________________________ 46
Technical Support __________________________________________________ 49
9: Connections and Pinouts 51
Serial Port _____________________________________________________ 51
Serial Connector Pinouts _________________________________________ 51
Null-Modem Cable ______________________________________________ 53
UDS10/UDS100 User Guide
6
Network Port ___________________________________________________ 53
Ethernet Connector Pinouts _______________________________________ 54
10: Technical Specifications 55
UDS10 Technical Specifications _______________________________________ 55
UDS100 Technical Specifications ______________________________________ 56
A: Alternative Ways to Assign an IP Address 57
DHCP ________________________________________________________ 57
AutoIP ________________________________________________________ 57
BOOTP _______________________________________________________ 58
ARP and Telnet _________________________________________________ 58
B: Binary to Hexadecimal Conversions 59
Converting Binary to Hexadecimal______________________________________ 59
Conversion Table _______________________________________________ 59
Scientific Calculator ______________________________________________ 60
Connect Mode Options ______________________________________________ 61
Disconnect Mode Options ____________________________________________ 64
Flush Mode Options_________________________________________________ 66
Interface Mode Options ______________________________________________ 72
Pack Control Options ________________________________________________ 73
Declaration of Conformity 75
Warranty 76
Index 77
Figures
Figure 2-1. Application Examples ________________________________________ 11
Figure 2-2. Sample Ethernet Address _____________________________________ 13
Figure 3-1. UDS Connected to Serial Device and Network _____________________ 14
Figure 4-1. Web Browser Login __________________________________________ 18
Figure 4-2. UDS Configuration Guidelines Page _____________________________ 19
Figure 4-3. Lantronix Web Manager ______________________________________ 20
Figure 4-4. Server Properties Configuration on the Web Browser________________ 21
Figure 5-1. Network Login Using Telnet____________________________________ 22
Figure 5-2. Setup Mode ________________________________________________ 23
Figure 5-3. Network Configuration ________________________________________ 24
Figure 5-4. Server Configuration Option ___________________________________ 26
Figure 5-5. Channel 1 Configuration ______________________________________ 26
Figure 5-6. Hostlist Option ______________________________________________ 30
Figure 5-7. Expert Settings Options_______________________________________ 35
Figure 5-8. Security Settings ____________________________________________ 36
Figure 6-1. TFTP Dialog Box ____________________________________________ 41
Figure 6-2. Sending Firmware to Another Unit_______________________________ 41
Figure 6-3. Firmware Upgrade Screen Display ______________________________ 42
Figure 7-1. Entering Monitor Mode Using the Network ________________________ 43
Figure 9-1. Serial Interface _____________________________________________ 51
Figure 9-2. DB25 Female DCE Interface RS232 _____________________________ 52
Figure 9-3. DB25 Female DCE Interface RS485/422 _________________________ 52
UDS10/UDS100 User Guide
7
Figure 9-4. Null-Modem Cable (Lantronix Part No. 500-163) ___________________ 53
Figure 9-5. Network Interface ___________________________________________ 53
Figure 9-6. RJ45 Ethernet Connector _____________________________________ 54
Tables
Table 5-1. Standard IP Network Netmasks _________________________________ 25
Table 5-2. Netmask Examples __________________________________________ 25
Table 5-3. Interface Mode Options _______________________________________ 27
Table 5-4. Common Interface Mode Settings _______________________________ 27
Table 5-5. Flow Control Options _________________________________________ 27
Table 5-6. Connect Mode Options________________________________________ 28
Table 5-7. Manual Connection Address Example ____________________________ 29
Table 5-8. Modem Mode Commands _____________________________________ 32
Table 5-9. Disconnect Mode Options _____________________________________ 33
Table 5-10. Flush Mode Options _________________________________________ 33
Table 5-11. Pack Control Options ________________________________________ 34
Table 7-1. Monitor Mode Commands _____________________________________ 44
Table 7-2. Command Response Codes ___________________________________ 44
Table 8-1. UDS10/UDS100 LEDs ________________________________________ 46
Table 8-2. Problems and Error Messages__________________________________ 46
8
1
1
:
:
U
U
s
s
i
i
n
n
g
g
T
T
h
h
i
i
s
s
G
G
u
u
i
i
d
d
e
e
Purpose and Audience
This guide provides the information needed to configure, use, and update the UDS
device server. It is for system administrators and those responsible for installing and
maintaining the UDS.
Chapter Summary
The remaining chapters in this guide include:
2: Introduction Describes the main features of the UDS and the protocols it
supports.
3: Getting Started Provides information for installing your unit and getting it up
and running.
4: Configuring the UDS
Using Web Manager
Provides instructions for accessing Web Manager and using
it to configure settings for the UDS.
5: Configuring the UDS
Using Telnet or the Serial
Port
Provides instructions for accessing Setup Mode (command
line interface) using a Telnet connection through the
network or a terminal or terminal emulation program through
the serial port. Details the settings that you must configure.
6: Updating Firmware Provides instructions for obtaining the latest firmware and
updating the UDS.
7: Using Monitor Mode Provides instructions for accessing and using the command
line interface to monitor the network and diagnose
problems.
8: Troubleshooting and
Contact Information
Describes common problems and error messages and how
to contact Lantronix Technical Support.
9: Connections and Pinouts Provides descriptions and illustrations of connection
hardware.
10: Technical Specifications Lists technical specifications for the UDS10 and the
UDS100.
A: Alternative Ways to
Assign an IP Address
Provides detailed information about using DHCP, AutoIP,
BOOTP ARP, and Telnet to assign an IP address.
B: Binary to Hexadecimal
Conversions
Provides instructions on converting binary values to
hexadecimals and tables listing all UDS configuration
options in hexadecimal notation.
UDS10/UDS100 User Guide Using This Guide
9
Additional Documentation
The following information is available on the product CD or the Lantronix Web
site:www.lantronix.com
DeviceInstaller User Guide Provides instructions for using the Windows-based utility to
configure the UDS and other Lantronix device servers. (CD
and web site)
“Live” Tutorials on the
Lantronix Web Site
Explain and demonstrate Assigning an IP address to the UDS
and Setting up the UDS and the Redirector. See
http://ts.lantronix.com/tutorials.html.
10
2
2
:
:
I
I
n
n
t
t
r
r
o
o
d
d
u
u
c
c
t
t
i
i
o
o
n
n
The UDS10 and UDS100 are single-port device servers that provide a quick, simple,
and cost-effective way to bring the advantages of data accessibility and remote
management to devices not currently connected to a network.
The main difference between the two models is that the UDS100 provides both half
and full duplex 10/100 Ethernet data transfer, whereas the UDS10 provides only half
duplex 10Base-T Ethernet. The technical specifications of the two products differ
slightly as well. Unless otherwise noted, we refer to both products as the UDS.
Applications
The UDS family of Device Servers allows serial devices, such as those listed below,
to connect and communicate over Ethernet networks using the IP protocol family
(TCP for connection-oriented stream applications and UDP for datagram
applications).
Security alarms
Access control devices
Fire control panels
Time/attendance clocks and terminals
ATM machines
Data collection devices
RFID readers
Universal Power Supply (UPS) management units
Telecommunications equipment
Data display devices
Virtually any asynchronous RS-232, RS422, or RS485 device.
Application Examples
Using a method called serial tunneling, the UDS encapsulates serial data into
packets and transports them over Ethernet. Using two UDS units, connected by a
network, virtual serial connections can extend across a facility or around the world.
The Com Port Redirector software included on the product CD simplifies the
integration process by extending the functionality of COM-port-based Windows™
applications. Virtual COM ports, mapped to remote device servers on the network,
can replace direct serial connections.
UDS10/UDS100 User Guide Introduction
11
Figure 2-1. Application Examples
Note: For step-by-step instructions on configuring the UDS for serial
tunneling or for use with the Com Port Redirector, access the UDS
Configuration Tutorials using Web Manager. (See Accessing Web Manager
on page 18.)
Introduction UDS10/UDS100 User Guide
12
Protocol Support
The UDS uses the Internet Protocol (IP) for network communications and the
Transmission Control Protocol (TCP) to assure that no data is lost or duplicated and
everything sent to the connection arrives correctly at the target.
Supported protocols include:
ARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, and SNMP for
network communications.
TCP, UDP, and Telnet for connections to the serial port.
TFTP for firmware updates.
IP for addressing, routing, and data block handling over the network.
User Datagram Protocol (UDP) for typical datagram applications in which
devices interact with other devices without a point-to-point connection.
Additional Features
Modem Emulation: In modem emulation mode, the UDS can replace dial-up
modems. The unit accepts modem AT commands on the serial port, and then
establishes a network connection to the end device, leveraging network connections
and bandwidth to eliminate dedicated modems and phone lines.
Built-in Web Server: The UDS includes a built-in web server for configuring the unit
and displaying operating and troubleshooting information on the attached links to
online support.
Configuration Methods
After installation, the UDS requires configuration. For the unit to operate correctly on
a network, it must have a unique IP address on the network. There are three basic
methods for logging into the UDS and assigning IP addresses and other configurable
settings:
DeviceInstaller: Configure the IP address and other network settings on the UDS
using a Graphical User Interface (GUI) on a PC attached to a network.
(See DeviceInstaller on page 16.)
Web Manager: Through a web interface configures the UDS settings using the
Lantronix Web Manager. (See 4: Configuring the UDS Using Web Manager.)
Serial and Telnet Ports: There are two approaches to accessing Setup Mode:
making a Telnet connection to the network port (9999) or connecting a terminal (or a
PC running a terminal emulation program) to the unit’s serial port.
(See 5: Configuring the UDS Using Telnet or the Serial Port.)
UDS10/UDS100 User Guide Introduction
13
Product Information Label
The product information label on the underside of the unit contains the following
information about your specific unit:
Bar code
Serial number
Product ID (name)
Product description
Hardware address (also referred to as the Ethernet or MAC address)
The first three bytes of the hardware address are fixed and read 00-20-4A, identifying
the unit as a Lantronix product. The fourth, fifth, and sixth bytes are unique numbers
assigned to each unit.
Figure 2-2. Sample Hardware Address
00-20-4A-14-01-18 or 00:20:4A:14:01:18
14
3
3
:
:
G
G
e
e
t
t
t
t
i
i
n
n
g
g
S
S
t
t
a
a
r
r
t
t
e
e
d
d
This chapter describes how to get your UDS up and running in the shortest possible
time.
Installing the UDS
Figure 3-1. UDS Connected to Serial Device and Network
To install the unit, complete the following steps in order. Refer to the numbers in the figure
above.
1. Connect a serial device to your unit. See 9: Connections and Pinouts for more
information about the device attachments the unit supports.
2. Connect an Ethernet cable to the RJ45 port.
3. Supply power to your unit using the power supply that was included in the
packaging.
Note: The required input voltage is 9-30 VDC or 9-24 VAC
(1 W maximum).
4. Supply power to the serial device.
Note: If you encounter a problem, please see LEDs on page 45 for
diagnostic information.
UDS10/UDS100 User Guide Getting Started
15
Required Information
Before configuring the UDS, have the following information available:
Hardware Address
Take note of the unit’s hardware address (also known as the Ethernet or MAC
address). It is on the product label, in the format: 00-20-4a-XX-XX-XX, where the XXs
are unique numbers assigned to the product (see Product Information Label on
page13).
Hardware Address: 00-20-4a-_____-_____-_____
IP Address
The UDS must have a unique IP address on your network. This address references
the specific unit. By default, the device is DHCP-enabled and automatically assigned
an IP address on DHCP-enabled networks. If you are assigning a static IP address,
the systems administrator generally provides the IP address, subnet mask, and
gateway.
Note: The factory default IP address is 0.0.0.0 to enable DHCP, BOOTP,
and AutoIP. When the units boots, it sends a DHCP broadcast to try and get
an IP address. If it receives no reply from a DHCP server, the UDS tries
BOOTP. If the UDS does not receive a response from BOOTP, it reverts to
an AutoIP address.
IP Address: _______ _______ _______ _______
Subnet Mask: ___
____ _______ _______ _______
Gateway: _______ _______ _______ _______
You have several options for assigning an IP to your unit. This chapter provides
information about using the DeviceInstaller (graphical user interface) and serial port
login (command line interface) methods.
Note: For information about other methods of assigning the IP address,
such as DHCP, AutoIP, ARP, and Telnet, see A: Alternative Ways to Assign
an IP Address.
Getting Started UDS10/UDS100 User Guide
16
Assigning the IP Address and Related Network Settings
This section describes two ways to assign the IP address and related network
settings quickly.
DeviceInstaller
Serial Port Login
DeviceInstaller
Note: The DeviceInstaller User Guide and the DeviceInstaller online help
provide more detailed information on using DeviceInstaller.
Installing DeviceInstaller
To use the DeviceInstaller utility, you first install it from the product CD.
1. Insert the product CD into your CD-ROM drive. The Lantronix UDS10/UDS100
DeviceInstaller window displays.
2. If the CD does not launch automatically:
a) Click the Start button on the Task Bar and select Run.
b) Enter your CD drive letter, colon, backslash, deviceinstaller.exe (e.g.,
E:\deviceinstaller.exe).
3. Click the DeviceInstaller button.
4. Respond to the installation wizard prompts. (When prompted to select an
installation type, select Typical.)
Assigning the IP Address and Network Class
1. Click the Start button on the Task Bar and select Programs Æ Lantronix Æ
DeviceInstaller Æ DeviceInstaller. The DeviceInstaller window displays.
2. Click the Assign IP icon. The Assign IP Address window displays.
3. Enter the hardware (Ethernet) address of the device.
4. Select Assign a specific IP address to assign a static IP address to the device
or select Obtain an IP address automatically to enable BOOTP, DHCP, or
Auto IP on the device.
5. Click Next.
6. Enter an IP address, subnet mask, and gateway for the device. Enter this
information in XXX.XXX.XXX.XXX format.
7. Click Next.
8. Click the Assign button to finalize the IP assignment.
UDS10/UDS100 User Guide Getting Started
17
Adding the Unit to the Manage List
Now add the unit to the list of similar Lantronix devices on the network so that you
can manage and configure it. To perform this step, click the Search icon.
DeviceInstaller locates the unit and adds it to the list. Now you can manage
(configure) the unit so that it works with the serial device on the network.
Methods of Configuring the UDS
Now that the UDS has an IP address and other initial settings, you can configure it
further by several methods.
Note: To assign Expert settings and Security settings, you must use the
Setup Mode window in a Telnet session.
To configure the unit using a Web browser, click the Web icon. The Lantronix
Web Manager window displays in your browser. Continue with 4: Configuring
the UDS Using Web Manager.
To configure the unit using a Telnet session or the serial port, click the
Telnet icon. The Setup Mode window displays. Continue with 5: Configuring
the UDS Using Telnet or the Serial Port.
Serial Port Login
To assign the IP address and other network settings using a serial connection, follow
these steps:
1. Connect a console terminal or a PC running a terminal emulation program to the
unit's serial port. The default serial port settings are 9600 baud, 8 bits, no parity,
1 stop bit, no flow control.
2. To enter Setup Mode, cycle the unit's power (power off and back on). After
power-up, the self-test begins and the red Diagnostic LED starts blinking. You
have one second to enter three lowercase x characters.
Note: The easiest way to enter Setup Mode is to hold down the x key at
the terminal (or emulation) while powering up the unit.
3. Select 0 (Server Configuration) and follow the prompts until you get to IP
address.
4. Enter the new IP address, subnet mask, and gateway (if applicable).
5. Do one of the following:
Continue with 5: Configuring the UDS Using Telnet or the Serial Port.
Select 9 to save and exit Setup Mode. The unit performs a power reset.
18
4
4
:
:
C
C
o
o
n
n
f
f
i
i
g
g
u
u
r
r
i
i
n
n
g
g
t
t
h
h
e
e
U
U
D
D
S
S
U
U
s
s
i
i
n
n
g
g
W
W
e
e
b
b
M
M
a
a
n
n
a
a
g
g
e
e
r
r
You must configure the UDS so that it can communicate on a network with your serial
device. For example, you must set the way the unit responds to serial and network
traffic, handles serial packets, and starts and closes connections.
This chapter gives an overview of the procedure for using Web Manager to configure
a UDS. This is the easiest and preferred method.
The unit’s configuration is stored in nonvolatile memory (NVRam) and is retained
without power. You can change the configuration at any time. The unit performs a
reset after the configuration has been changed and stored.
Accessing Web Manager
If your unit already has an IP address, you can log into it using a standard Web
browser with Java enabled.
1. Type the unit's IP address into the Web browser's URL (Address/Location) field.
Figure 4-1. Web Browser Login
Note: You can also access Web Manager by clicking the Web icon on the
DeviceInstaller “Manage List” window (see Methods of Configuring the UDS
on page 17.)
2. When the UDS Configuration Guidelines Page displays, select one of the four
links:
UDS10/UDS100 User Guide Configuring the UDS Using Web Manager
19
Figure 4-2. UDS Configuration Guidelines Page
UDS settings opens a configuration window to configure the
UDS10/UDS100, as shown in Figure 4-3.
Serial cabling lets you view pinouts for the UDS serial port.
View UDS Configuration Tutorials provides step-by-step instructions for
configuring serial tunneling and the Com Port Redirector.
Technical Support lets you download the latest firmware for your UDS and
view documentation.
Configuring the UDS Using Web Manager UDS10/UDS100 User Guide
20
Using Web Manager
1. To configure the unit, select UDS Settings on the UDS Configuration Guidelines
Page. The Web Manager page displays.
Figure 4-3. Lantronix Web Manager
2. Use the menu (pushbuttons) to navigate to sub pages where you can configure
server settings.
Note: For detailed explanations of the settings, see 5: Configuring
the UDS Using Telnet or the Serial Port.
3. When you are finished, click the Update Settings button to save your settings.
Example
For example, to enter server properties:
1. Click the Server Properties button. The Server Properties section of the Web
page displays.
2. Confirm or enter values for
IP Address
Subnet Mask
Gateway Address
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78

Lantronix UDS-10 User manual

Category
Networking
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI