Introduction to 8007 Electronic Components - 1
Key Start Troubleshooting Flow Chart 1 – 2
Active Start Troubleshooting Flow Chart 2 – 3
No Active Start - Generator/Sensor Test – 4
No Active Start - Drive/Display Test – 5
No Active Start - Sensor/Drive Test – 6
No Key Start - Drive/Display Test - 7
1
SportsArt - 8007 Elliptical Trainer - “No Start” Troubleshooting Guide
Introduction to 8007 Electronic Components
1
Generator
Magnet and
Flywheel
Optic Sensor
Battery
Drive Board
2
SportsArt - 8007 Elliptical Trainer - “No Start” Troubleshooting Guide
Key Start Troubleshooting Flow Chart
START
Place probes on battery terminals. Without
moving the pedals or arm bars, press the
display panel ON key. Does the meter show
5.2V or more?
Yes
No
Recharge the battery: Adjust LEVEL to
lowest position; Run at 50-60 rates per
minute for half an hour. Or replace the
battery.
Without moving the pedals
or arm bars, release the
ON key. Does the display
remain lit 2 minutes before
turning off?
Yes
Normal
END
No
Does the display turn
off immediately?
Yes
No
See page 7 to determine
whether issue is in the
display board or drive board.
If the display doesn't black out
immediately but turns off in less
than two minutes, replace the
drive board (capacitor EC9
220U/16V).
2
3
SportsArt - 8007 Elliptical Trainer - “No Start” Troubleshooting Guide
Active Start Troubleshooting Flow Chart
START
Exercise on the unit.
Does the display light
up automatically?
No
Possible malfunction: optic
sensor, drive board, optic
sensor cable. Please see
page 7.
Yes
Normal
END
Test generator output. If
none, replace the
generator. If so, inspect
the optic sensor by
probing into drive board
CN1 pins 1 and 2. Voltage
should vary with speed.
Please see page 4.
The optic sensor is good. Possible
malfunction: display board, drive board, data
cable. Please see pages 5 and 6.
Yes
No
3
4
SportsArt – 8007 Elliptical Trainer - “No Start” Troubleshooting Guide
No Active Start - Generator/Sensor Test
Exercise on the unit. Place probes on generator wires. Generator output voltage (VDC) should vary
according to speed. If not, replace the generator. If generator is good, inspect the optic sensor.
Place probes on drive board connector CN1 pins 1 and 2 as shown. Voltage should vary with speed
from 0~5VDC.If voltage does vary, the optic sensor is functioning normally. Inspect the drive and
display circuit boards. See page 5. If voltage does not vary, inspect the optic sensor and drive board.
See page 6.
4
5
SportsArt - 8007 Elliptical Trainer - “No Start” Troubleshooting Guide
No Active Start – Drive/Display Test
Condition: Voltage across drive board connector CN1 pin 1 and IC U3 (40106) pin 4 should vary
from 0~5VDC.
Response: If voltage does not vary, replace the drive board. Possible bad components: IC U3(40106)
or U2(LM339) (see below). If voltage varies, the drive board is good. Perform a continuity test on the
main data cable. If it is good, replace the display. If it is bad, replace the data cable.
5
U3(40106)I
U2(LM339)IC
6
SportsArt - 8007 Elliptical Trainer “No Start” Troubleshooting Guide
No Active Start – Sensor/Drive Test
Condition: Voltage across drive board CN1 connector pin 1 and 2 does not vary.
Response: Inspect optic sensor power supply from the drive board. Place probes as shown
across the red and green wires. Normal specification: 5VDC. If there is no power to the optic
sensor, replace the drive board. If there is voltage off the drive board, but no returning signal
(page 4), replace the optic sensor. Note: also inspect optic sensor wire by performing continuity
test on the wire.
6
7
SportsArt - 8007 Elliptical Trainer - “No Start” Troubleshooting Guide
No Key Start – Drive/Display Test
Condition: No one is exercising on the unit; battery voltage is appropriate; the display lights briefly
when the ON key is pressed but shuts off as soon as the ON key is not pressed.
Response:Test D7 diode voltage: Place the black probe on the negative end of CN2; place the red
probe on the positive end of diode D7. Normal voltage: 0~0.5V. If the voltage is normal, the drive
board automatic shut off function is malfunctioning. Replace drive board IC U10(HT7044) or
U3(40106) or capacitor EC11(2.2UF) or transistor Q5(C1815). If voltage exceeds 5VDC , the display
board (“shut off” signal emission) is malfunctioning. Replace the display.
7
8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

SportsArt Fitness “No Start” 8007 Troubleshooting Manual

Type
Troubleshooting Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI